Ansys Assistant will be unavailable on the Learning Forum starting January 30. An upgraded version is coming soon. We apologize for any inconvenience and appreciate your patience. Stay tuned for updates.
General

General

Which information is stored in the file created by “Export Sensitivities” in the Design Tool of the Adjoint Solver?

    • FAQFAQ
      Participant

      The export file includes information about the sensitivities for the selected observables. The content looks similar like this:
      2
      pressure-drop
      pressure
      586117
      -2.3940486949e-02 -2.5516001772e-02 8.9298445901e-03 1.5480221472e-02 -2.4944924009e+00 -5.1062139430e+00
      -2.3732484028e-02 -2.5075830114e-02 8.6952040392e-03 -1.7825729374e-02 -1.7257830369e+00 -3.1191569793e+00
      -2.3886182625e-02 -2.4326236107e-02 8.2269932966e-03 -7.6775105648e-03 -1.1233146632e+00 -1.6108357175e+00

      The 6 columns denote the 3 coordinates for each node 3 nodal sensitivities. The unit is unit of observable / m