Multiphase Flows

Multiphase Flows

What are the units for the expert parameter “pt minimum diameter”?

    • FAQFAQ
      Participant

      The expert parameter “pt minimum diameter” is used to eliminate small particles in a particle evaporation model. The default solver units are SI and thus “pt minimum diameter” is assumed to be in [m]. As units can be set to whatever system is desired in CFX-Pre and CFX-Post, there is really no need to change the default solver units from SI.