General

General

In a StrainLife fatigue analysis (EN) using ANSYS nCode DesignLife is it possible to plot the stress vs strain hysteresis loops at a node?

    • FAQFAQ
      Participant

      No. ANSYS nCode DesignLife cannot plot the stress vs strain hysteresis loop for an EN analysis. The strain data is adjusted (mean stress correct, elastic-plastic correction, notch sensitivity correction, surface finish, etc.) during the EN analysis. The original strain data is not retained.