Structural & Thermal

Structural & Thermal

Why a coupled-field transient thermal analysis shows negative temperature?

    • FAQFAQ
      Participant

      The thermoelastic damping matrix is probably the source of the problem. Add “keyopt,matid,9,1” for all of the coupled-field bodies.