Is it possible to define multiple load (Heat generation rate) in table type array parameter using a *DO loop?

    • FAQFAQ
      Participant

      Yes. The following APDL commands demonstrate how to define multiple loads using *do loop;

      Fini
      /clear
      /output,out,out

      *cfopen,load,txt
      *Do,i,1,2

      *DIM,BF%i%LOAD,TABLE,3,1,1,time,

      BF%i%LOAD(1,0) = 0,0.5,1
      BF%i%LOAD(1,1) = %i%*10,%i%*20,%i%*30

      *vwrite,i,i
      bfv,%i,hgen,%%BF%iLOAD%%

      *enddo
      *cfclos

      !create Solid model and mesh it
      /prep7

      mp,kxx,1,50
      mp,dens,1,7850
      mp,c,1,450

      et,1,70
      block,,10,,1,,1
      block,10.1,20.1,,1,,1
      esize,.3
      vmesh,all

      /inp,load,txt

      /solu
      ANTYPE,4
      TRNOPT,FULL
      LUMPM,0
      TIME,1
      solve
      /post1
      /EFACET,1
      PLNSOL, TEMP,, 0