Ansys Assistant will be unavailable on the Learning Forum starting January 30. An upgraded version is coming soon. We apologize for any inconvenience and appreciate your patience. Stay tuned for updates.
Multiphase Flows

Multiphase Flows

How to convert J/kg to Joule per mole?

    • FAQFAQ
      Participant

      In ANSYS Fluent the dimension of the molecular weight is expressed in kg/kmol (kg/kgmol = kg per 1000 moles). So to get the correct input of heat of vaporization or in general the standard state enthalpy of particular fluid at a reference temperature for Fluent the conversion below is required:
      standard state enthalpy in [J/kg]* Molar Mass [kg/kgmol] = Latent Heat in [J/kgmol ] Keywords: Latent Heat, kg/kmol, molecular weight