In non-linear analysis, Is the stiffness update done for each iteration or for each sub step?
By default, for most of the non-linear analysis the stiffness update is done for each iteration in Ansys.
But how to update the stiffness during the nonlinear Newton Raphson solution procedure can be controlled with NROPT command.