How to calculate NOX values in CFD-Post in units of ppm on a DRY BASIS.

    • FAQFAQ
      Participant

      1. Create the Expression : NOX ppm dry exp = NO.Mole Fraction* 10^6 /(1 – H2O.Mole Fraction) 2. Create the Variable, NOX ppm dry and set it equal to the expression: NOX ppm dry exp