General

What if make-periodic option form Fluent TUI does not work due to offset?

    • FAQFAQ
      Participant

      An alternative way in such case can be to change the two periodic surface types to interfaces. Then create a manual interface using these two surfaces and put ‘Periodic Boundary Condition’ as the condition. Also use the offset values that is shown in the error message when using ‘make-periodic’ command. This should create a non conformal interface with periodic conditions and should work fine.