General

General

How can I display wall shear stress based on ‘time averaged velocity’ in CFD-Post?

    • FAQFAQ
      Participant

      In CFX-Pre, Under Output Control, include the variable Wall Shear under Transient Statistics using the option “Arithmetic Average”. The start/stop iteration number can be set to allow averaging over a certain iteration number range. In CFD-Post, a new variable called “Wall Shear.Trnavg” will be available and represents the time-averaged value of wall shear over the averaging interval.