The following warning is appearing: Warning: The neighboring cell threads (3 and 2) of semi-transparent wall zone 11 are not fluid

    • SolutionSolution
      Participant

      Use the solar load model to implement the initialization. The following warning may appear: Warning: The neighboring cell threads (3 and 2) of semi-transparent wall zone 11 are not fluid. This problem MUST be fixed before proceeding! This is displayed when you are in a combination of the following settings: Solar Ray Tracing model solid zone adjacent to and semi-transparent wall Since the above-mentioned conditions cannot be used together, you can apply the solar ray tracing model using the DO irradiation model. You may also need to change the fluid zone. Also, please note that the numbers in the message represents a zone ID.