We’re putting the final touches on our new badges platform. Badge issuance remains temporarily paused, but all completions are being recorded and will be fulfilled once the platform is live. Thank you for your patience.
General

General

I am using the Fluent fan model and I see no way to enter my fan curve except for point-by-point, and there is no way to verify or plot the points I have entered. Also, the units are not typical to a fan curve – they are in m/s rather than CFM Is there a way in Fluent to simulate a fan and just read in the fan curve as CFM/Pressure?

    • FAQFAQ
      Participant

      The 2D fan model is limited to Pressure/velocity inputs and is generally intended for more simplified representations of fans. You can check the inputs to the fan curve using the procedure outlined in Solution 2039208. To supply a CFM/Pressure fan curve as input, use the more sophisticated 3D fan model, described in the link below https://ansyshelp.ansys.com/account/secured?returnurl=/Views/Secured/corp/v191/flu_ug/flu_ug_sec_bc_3d_fan.html?q=fan model The inputs to the 3D fan model allow the reading of a fan curve with pressure as a function of volumetric flowrate. The format is: cell zone id 17!CELL_ID Pressure(Pa)Flowrate(m3/s) -324.01.255 -215.01.162 -109.01.032 0.0 0.997 63.00.913 105.00.862 302.00.584 394.00.492 406.00.432 443.00.365