{"id":199016,"date":"2026-06-11T22:04:39","date_gmt":"2026-06-11T22:04:39","guid":{"rendered":"https:\/\/innovationspace.ansys.com\/knowledge\/?post_type=topic&#038;p=199016"},"modified":"2026-06-11T22:13:27","modified_gmt":"2026-06-11T22:13:27","slug":"what-are-the-limitations-of-sph-adaptive-size-in-ansys-freeflow","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-are-the-limitations-of-sph-adaptive-size-in-ansys-freeflow\/","title":{"rendered":"What are the limitations of SPH Adaptive Size in Ansys FreeFlow?"},"content":{"rendered":"<h1  id=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-198650 size-full\" src=\"https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2026\/05\/Freeflow-FAQ-banner-v2.png\" alt=\"\" width=\"1600\" height=\"200\" srcset=\"https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2026\/05\/Freeflow-FAQ-banner-v2.png 1600w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2026\/05\/Freeflow-FAQ-banner-v2-300x38.png 300w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2026\/05\/Freeflow-FAQ-banner-v2-1024x128.png 1024w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2026\/05\/Freeflow-FAQ-banner-v2-768x96.png 768w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2026\/05\/Freeflow-FAQ-banner-v2-1536x192.png 1536w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2026\/05\/Freeflow-FAQ-banner-v2-24x3.png 24w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2026\/05\/Freeflow-FAQ-banner-v2-36x5.png 36w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2026\/05\/Freeflow-FAQ-banner-v2-48x6.png 48w\" sizes=\"auto, (max-width: 1600px) 100vw, 1600px\" \/><\/h1>\n<h1  id=\"WHAT-ARE-THE-LIMITATIONS-OF-SPH-ADAPTIVE-SIZE-IN-ANSYS-FREEFLOW\"><strong>What are the limitations of SPH Adaptive Size in Ansys FreeFlow?<\/strong><\/h1>\n<p>SPH Adaptive Size in Ansys FreeFlow has a few important limitations that users should consider when setting up simulations and analyzing results.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>1.Mass Loss Near Boundaries<\/strong><\/p>\n<p>When SPH Adaptive Size is used with <strong>boundary<\/strong>\u2011<strong>based refinement<\/strong>, mass loss may occur near walls. During refinement close to a geometry boundary, some refined SPH elements can be placed partially inside or overlapping the wall. To maintain numerical stability, these elements are excluded from the simulation, which may result in a local loss of mass.<\/p>\n<p><strong>Recommendation: <\/strong>Use <strong>Region of Interest (ROI)\u2013based refinement<\/strong> instead of boundary proximity refinement. ROI refinement reduces the likelihood of refined elements intersecting boundaries and generally provides better control over refinement regions.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>2.Numerical Precision and Truncation Errors<\/strong><\/p>\n<p>The FreeFlow solver uses <strong>single<\/strong>\u2011<strong>precision arithmetic<\/strong>. As a result, <strong>truncation errors<\/strong> may appear when SPH Adaptive Size is enabled. This issue can arise if the <strong>ratio between the finer and coarser<\/strong> <strong>elements is too big<\/strong>. . This is because adaptive refinement further reduces the element size, increasing sensitivity to floating\u2011point precision.<\/p>\n<p><strong>Recommendation:\u00a0<\/strong>Avoid floating point precision problems by setting up to 2 levels of refinement.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>3.IISPH Solver\u2011Specific Behavior<\/strong><\/p>\n<p>When SPH Adaptive Size is combined with the <strong>IISPH solver<\/strong>, users may observe <strong>pressure fluctuations<\/strong> that can affect simulation results. This behavior is less pronounced when using WCSPH.<\/p>\n<p>To address this limitation, Ansys FreeFlow offers the Relaxed Incompressibility Constraint feature, available exclusively for the <strong>IISPH solver<\/strong>.<\/p>\n<p><strong>Recommendation: <\/strong>For more stable and accurate results when using IISPH with SPH Adaptive Size, enable the <strong>Relaxed Incompressibility Constraint<\/strong>.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>\u00a04.<\/strong><strong>Post\u2011Processing and Element ID Tracking<\/strong><\/p>\n<p>SPH Adaptive Size dynamically creates and removes SPH elements during refinement and coarsening. As a result:<\/p>\n<ul>\n<li>Original SPH elements are deleted when refinement occurs<\/li>\n<li>New refined elements receive new Element IDs<\/li>\n<li>Element ID numbering is <strong>reorganized at each refinement iteration<\/strong><\/li>\n<\/ul>\n<p>Because of this behavior, <strong>Element IDs are not consistent over time<\/strong>, making element tracking unreliable.<\/p>\n<p><strong>Recommendation: <\/strong>Do not rely on Element ID tracking for adaptive simulations. However, if an original Element ID disappears from the simulation, this indicates that the element was refined.<\/p>\n<div class=\"packages-rocky\">\n<div class=\"additional-package-rocky col-md-5\">\n<p>Access more FAQs and Tips in the page:<\/p>\n<div><a class=\"download\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/ansys-freeflow-faqs-and-tips\/\" target=\"_blank\" rel=\"noopener\">FreeFlow FAQs and Tips<\/a><\/div>\n<\/div>\n<\/div>\n<div>\n<h6 class=\"paragraph\" style=\"text-align: center\" align=\"right\" class=\"paragraph\" style=\"text-align: center\" align=\"right\"  id=\"ANSYS-FREEFLOW-SMOOTHED-PARTICLE-HYDRODYNAMICS-SPH-SIMULATION-SOFTWARE\"><span class=\"eop\"><span style=\"font-size: 16.0pt\"><em>Ansys FreeFlow\u2122 smoothed-particle hydrodynamics (SPH) simulation software<\/em> <\/span><\/span><\/h6>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"template":"","class_list":["post-199016","topic","type-topic","status-publish","hentry","topic-tag-adaptive-size-limitations","topic-tag-ansys-freeflow","topic-tag-ansys-freeflow-faqs","topic-tag-faqs-sph","topic-tag-freeflow-sph","topic-tag-sph","topic-tag-sph-adaptive-size","filter-by-application-ansys-freeflow","application-products-ansys-freeflow"],"aioseo_notices":[],"acf":[],"custom_fields":[{"0":{"_edit_lock":["1781215901:17114"],"_edit_last":["17114"],"_aioseo_title":[null],"_aioseo_description":[null],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_title":[null],"_aioseo_og_description":[null],"_aioseo_og_article_section":[""],"_aioseo_og_article_tags":["a:0:{}"],"_aioseo_twitter_title":[null],"_aioseo_twitter_description":[null],"application_name":[""],"_application_name":["field_64a80903c8e15"],"filter_by_optics_product":["Lumerical"],"_filter_by_optics_product":["field_64fb192ba3121"],"family":[""],"_family":["field_64a809229a857"],"siebel_km_number":[""],"_siebel_km_number":["field_63ecbffce60db"],"salesforce_km_number":[""],"_salesforce_km_number":["field_63ecc018e60dc"],"km_published_date":[""],"_km_published_date":["field_64c77704499dd"],"product_version":[""],"_product_version":["field_64c776cb4fd2e"],"_bbp_forum_id":["27796"],"_bbp_topic_id":["199016"],"_bbp_author_ip":["192.104.24.234"],"_bbp_last_reply_id":["0"],"_bbp_last_active_id":["199017"],"_bbp_last_active_time":["2026-06-11 22:04:39"],"_bbp_reply_count":["0"],"_bbp_reply_count_hidden":["0"],"_bbp_voice_count":["0"],"_btv_view_count":["30"],"_bbp_likes_count":["1"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/199016","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":4,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/199016\/revisions"}],"predecessor-version":[{"id":199019,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/199016\/revisions\/199019"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=199016"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}