{"id":197794,"date":"2025-12-08T20:50:29","date_gmt":"2025-12-08T20:50:29","guid":{"rendered":"https:\/\/innovationspace.ansys.com\/knowledge\/?post_type=topic&#038;p=197794"},"modified":"2025-12-08T22:13:10","modified_gmt":"2025-12-08T22:13:10","slug":"what-is-point-cloud-in-ansys-rocky","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-is-point-cloud-in-ansys-rocky\/","title":{"rendered":"[Rocky FAQs] What is Point Cloud in Ansys Rocky?"},"content":{"rendered":"<h1  id=\"WHAT-IS-POINT-CLOUD-IN-ANSYS-ROCKY\">What is Point Cloud in Ansys Rocky?<\/h1>\n<p>Point Clouds enable you to import a <strong>simple text file containing field data<\/strong> to define points in space. They are very useful to <strong>support External Modules<\/strong> that require information that varies through all 3 dimensions of the simulation domain.<\/p>\n<div class=\"attachment\" style=\"background-color: #fedb8d;padding: 1%;font-weight: 300;height: auto!important;display: flex;border-radius: 15px;margin-bottom: 20px\">Rocky software allows you to create Static Point Clouds with different dimensions and units, moreover, you can load a set of point clouds at once by importing a Transient Point Cloud text file, which specifies the start and end times for individual static point clouds.<\/div>\n<p>This data can then be used by Rocky software in various ways depending upon the functionality of the External Module (<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/ready-to-use-module\/?template=rocky\">Ready-to-use Modules<\/a> or <a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/rocky-sdk-package-api-solver\/?template=rocky\">Customer Custom External modules<\/a> created with Rocky Solver SDK) making use of the Point Cloud to read external data that are used by the modules to introduce different physics to the solver.<\/p>\n<p>Firstly, you need to <strong>create a .txt file<\/strong> with the values you want separating with spaces or commas. Just pay attention that the first row must contain x, y, z and at least one scalar variable (see the example below). The following row must contain the values for each point.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-197797 size-full\" src=\"https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/point-cloud-1.png\" alt=\"\" width=\"361\" height=\"134\" srcset=\"https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/point-cloud-1.png 361w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/point-cloud-1-300x111.png 300w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/point-cloud-1-24x9.png 24w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/point-cloud-1-36x13.png 36w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/point-cloud-1-48x18.png 48w\" sizes=\"auto, (max-width: 361px) 100vw, 361px\" \/><\/p>\n<p><strong>Transient Point Clouds<\/strong><\/p>\n<p>Transient Point Clouds consist of sets of Static Point Clouds that are applied during the simulation <strong>following specific start and end times<\/strong>. In order to import a Transient Point Cloud, it is necessary to import a main <strong>text, csv or xlsx file<\/strong> containing the start and end times of each Static Point Cloud that will be then automatically imported to compose the Transient Point Cloud. If desired, an optional third column with the name of the files (with the file extension) for each start and stop time, as shown below:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-197798 size-full\" src=\"https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/point-cloud-2.png\" alt=\"\" width=\"430\" height=\"155\" srcset=\"https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/point-cloud-2.png 430w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/point-cloud-2-300x108.png 300w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/point-cloud-2-24x9.png 24w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/point-cloud-2-36x13.png 36w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/point-cloud-2-48x17.png 48w\" sizes=\"auto, (max-width: 430px) 100vw, 430px\" \/><\/p>\n<p>For more information, about creating and adding Static and Transient Point Clouds refer to the section <a href=\"https:\/\/ansysproducthelpqa.win.ansys.com\/account\/secured?returnurl=\/Views\/Secured\/corp\/v261\/en\/dem_ug\/set-simulation-parameters.html%23add-and-edit-point-clouds\">About Point Clouds<\/a> in the <a href=\"https:\/\/ansyshelp.ansys.com\/public\/account\/secured?returnurl=\/Views\/Secured\/prod_page.html?pn=Rocky&amp;pid=rockydem&amp;lang=en\">Rocky User Manual<\/a>.<\/p>\n<p class=\"paragraph\" style=\"text-align: right\" align=\"right\"><span class=\"eop\"><span style=\"font-size: 16.0pt\">Ansys Rocky\u2122 particle dynamics simulation software <\/span><\/span><\/p>\n<p class=\"paragraph\" style=\"text-align: right\" xml:lang=\"EN-US\" align=\"right\"><span data-ccp-props=\"{\"><span class=\"eop\"><span style=\"font-size: 16.0pt\">Learn more about Ansys Rocky\u2122 software in <strong><a href=\"https:\/\/innovationspace.ansys.com\/ais-rocky\/\" data-wpel-link=\"external\">Ansys Rocky\u00a0 Innovation Space<\/a>.<\/strong><\/span><\/span><\/span><\/p>\n<p style=\"text-align: right\" xml:lang=\"EN-US\" align=\"right\"><strong><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-197810\" src=\"https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/author-foto.png\" alt=\"\" width=\"140\" height=\"143\" srcset=\"https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/author-foto.png 274w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/author-foto-24x24.png 24w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/author-foto-36x36.png 36w, https:\/\/innovationspace.ansys.com\/knowledge\/wp-content\/uploads\/sites\/4\/2025\/12\/author-foto-48x48.png 48w\" sizes=\"auto, (max-width: 140px) 100vw, 140px\" \/><\/strong><\/p>\n<h3 style=\"text-align: right\" style=\"text-align: right\"  id=\"JANAINA-OLIVEIRA\"><strong>Janaina Oliveira<\/strong><\/h3>\n<p style=\"text-align: right\"><em><strong>Technical\/Product Publications<\/strong><\/em><\/p>\n","protected":false},"template":"","class_list":["post-197794","topic","type-topic","status-publish","hentry","topic-tag-ansys-rocky","topic-tag-ansys-rocky-point-clouds","topic-tag-point-clouds","topic-tag-rocky-modules","topic-tag-transient-point-cloud","filter-by-application-ansys-rocky","application-products-ansys-rocky"],"aioseo_notices":[],"acf":[],"custom_fields":[{"0":{"_edit_lock":["1765389544:17114"],"_edit_last":["17114"],"_aioseo_title":[null],"_aioseo_description":[null],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_title":[null],"_aioseo_og_description":[null],"_aioseo_og_article_section":[""],"_aioseo_og_article_tags":["a:0:{}"],"_aioseo_twitter_title":[null],"_aioseo_twitter_description":[null],"application_name":[""],"_application_name":["field_64a80903c8e15"],"filter_by_optics_product":["Lumerical"],"_filter_by_optics_product":["field_64fb192ba3121"],"family":["Fluids"],"_family":["field_64a809229a857"],"siebel_km_number":[""],"_siebel_km_number":["field_63ecbffce60db"],"salesforce_km_number":[""],"_salesforce_km_number":["field_63ecc018e60dc"],"km_published_date":[""],"_km_published_date":["field_64c77704499dd"],"product_version":[""],"_product_version":["field_64c776cb4fd2e"],"_bbp_forum_id":["180025"],"_bbp_topic_id":["197811"],"_bbp_author_ip":["192.104.24.225"],"_bbp_last_reply_id":["0"],"_bbp_last_active_id":["197795"],"_bbp_last_active_time":["2025-12-08 20:50:29"],"_bbp_reply_count":["0"],"_bbp_reply_count_hidden":["0"],"_bbp_voice_count":["0"],"_btv_view_count":["483"],"_bbp_likes_count":["1"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/197794","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":13,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/197794\/revisions"}],"predecessor-version":[{"id":197811,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/197794\/revisions\/197811"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=197794"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}