{"id":179470,"date":"2023-08-25T12:16:29","date_gmt":"2023-08-25T12:16:29","guid":{"rendered":"\/knowledge\/forums\/topic\/how-can-we-set-a-simulation-end-time-which-is-less-than-the-smallest-default-1e-9\/"},"modified":"2023-08-25T12:16:29","modified_gmt":"2023-08-25T12:16:29","slug":"how-can-we-set-a-simulation-end-time-which-is-less-than-the-smallest-default-1e-9","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-can-we-set-a-simulation-end-time-which-is-less-than-the-smallest-default-1e-9\/","title":{"rendered":"How can we set a simulation end time which is less than the smallest default, 1e-9?"},"content":{"rendered":"<p>This is currently not possible through the Mechanical GUI. However, you can accomplish this through the use of a commands object as described in the attachments.  Also, consider using a smaller unit for time as an alternative to using very small numbers. <\/p>\n<p>Attachments:<br \/>\n1. <a href=https:\/\/ansys13.ansys.com\/KnowledgeArticles\/Phase-3\/2044670\/2044670.pdf>2044670.pdf<\/a><\/p>\n","protected":false},"template":"","class_list":["post-179470","topic","type-topic","status-publish","hentry","topic-tag-17-1","topic-tag-mechanical","topic-tag-static","topic-tag-structural-mechanics-structural","topic-tag-structural-and-thermal","topic-tag-structural-mechanics"],"aioseo_notices":[],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"siebel_km_number":["2044670"],"_bbp_last_active_time":["8\/25\/2023 20:20"],"_bbp_forum_id":["27795"],"_bbp_author_ip":["23.56.168.180"],"application_name":["Mechanical"],"family":["Structural Mechanics"],"km_published_date":["2016-11-08T00:00:00.000Z"],"product_version":["17"],"_btv_view_count":["648"]},"test":"solution"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/179470","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/179470\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=179470"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}