{"id":171386,"date":"2023-06-05T07:06:13","date_gmt":"2023-06-05T07:06:13","guid":{"rendered":"\/knowledge\/forums\/topic\/iges-import-with-the-legacy-reader-not-working\/"},"modified":"2023-07-31T12:30:28","modified_gmt":"2023-07-31T12:30:28","slug":"iges-import-with-the-legacy-reader-not-working","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/iges-import-with-the-legacy-reader-not-working\/","title":{"rendered":"IGES import with the legacy reader not working"},"content":{"rendered":"<p>Symptom: IGES data can&#8217;t be imported with the legacy reader which can be obtained on the Customer Portal V17.2 &#8211; Legacy Tools.  Solution: The procedure search internally for the file tintops.exe. This doesn&#8217;t exists in 18.1.  Create a text file in the <Installation folder>.e.g. c:Program FilesANSYS Incv181icemcfdwin64_amdbin and rename it to tintops.exe. The routine will pass this check and imports your IGES with the legacy readers.  As alternative use the File > Import Model function<\/p>\n","protected":false},"template":"","class_list":["post-171386","topic","type-topic","status-publish","hentry","topic-tag-18-1","topic-tag-cad-interface","topic-tag-fluid-dynamics","topic-tag-general","topic-tag-icem-cfd"],"aioseo_notices":[],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["2\/6\/2023 20:20"],"_bbp_forum_id":["27796"],"_bbp_author_ip":["209.182.204.162"],"_btv_view_count":["531"],"siebel_km_number":["2050405"],"product_version":["18.1"],"km_published_date":["2017-06-09T00:00:00.000Z"],"family":["Fluid Dynamics"],"application_name":["ICEM CFD"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/171386","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/171386\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=171386"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}