{"id":171294,"date":"2023-06-05T07:06:05","date_gmt":"2023-06-05T07:06:05","guid":{"rendered":"\/knowledge\/forums\/topic\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\/"},"modified":"2023-07-31T12:30:17","modified_gmt":"2023-07-31T12:30:17","slug":"i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\/","title":{"rendered":"I ran a transient flamelet (partially premixed combustion) case and forgot to do a statistical average of density, but I  averaged other key variables.  How can I get the time-averaged density without rerunning my transient simulation? Can I get it from the PDF tables?"},"content":{"rendered":"<p>The PDF table has an encrypted format that is proprietary, so no calls can be made to it to retrieve density.  However, density can be estimated from the ideal gas law, or an approximation equivalent to that made in the PDF tables.<\/p>\n","protected":false},"template":"","class_list":["post-171294","topic","type-topic","status-publish","hentry","topic-tag-18-1","topic-tag-bcs-interfaces","topic-tag-fluent","topic-tag-fluid-dynamics","topic-tag-materials","topic-tag-reacting-flow","topic-tag-species-reactions"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"The PDF table has an encrypted format that is proprietary, so no calls can be made to it to retrieve density. However, density can be estimated from the ideal gas law, or an approximation equivalent to that made in the PDF tables.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"I ran a transient flamelet (partially premixed combustion) case and forgot to do a statistical average of density, but I averaged other key variables. How can I get the time-averaged density without rerunning my transient simulation? Can I get it from the PDF tables? | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"The PDF table has an encrypted format that is proprietary, so no calls can be made to it to retrieve density. However, density can be estimated from the ideal gas law, or an approximation equivalent to that made in the PDF tables.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-06-05T07:06:05+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:30:17+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"I ran a transient flamelet (partially premixed combustion) case and forgot to do a statistical average of density, but I averaged other key variables. How can I get the time-averaged density without rerunning my transient simulation? Can I get it from the PDF tables? | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"The PDF table has an encrypted format that is proprietary, so no calls can be made to it to retrieve density. However, density can be estimated from the ideal gas law, or an approximation equivalent to that made in the PDF tables.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"name\":\"fluent\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"position\":3,\"name\":\"fluent\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\\\/#listItem\",\"name\":\"I ran a transient flamelet (partially premixed combustion) case and forgot to do a statistical average of density, but I  averaged other key variables.  How can I get the time-averaged density without rerunning my transient simulation? Can I get it from the PDF tables?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\\\/#listItem\",\"position\":4,\"name\":\"I ran a transient flamelet (partially premixed combustion) case and forgot to do a statistical average of density, but I  averaged other key variables.  How can I get the time-averaged density without rerunning my transient simulation? Can I get it from the PDF tables?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"name\":\"fluent\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\\\/\",\"name\":\"I ran a transient flamelet (partially premixed combustion) case and forgot to do a statistical average of density, but I averaged other key variables. How can I get the time-averaged density without rerunning my transient simulation? Can I get it from the PDF tables? | Ansys Knowledge\",\"description\":\"The PDF table has an encrypted format that is proprietary, so no calls can be made to it to retrieve density. However, density can be estimated from the ideal gas law, or an approximation equivalent to that made in the PDF tables.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\\\/#breadcrumblist\"},\"datePublished\":\"2023-06-05T07:06:05+00:00\",\"dateModified\":\"2023-07-31T12:30:17+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"I ran a transient flamelet (partially premixed combustion) case and forgot to do a statistical average of density, but I averaged other key variables. How can I get the time-averaged density without rerunning my transient simulation? Can I get it from the PDF tables? | Ansys Knowledge","description":"The PDF table has an encrypted format that is proprietary, so no calls can be made to it to retrieve density. However, density can be estimated from the ideal gas law, or an approximation equivalent to that made in the PDF tables.","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","name":"fluent"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","position":3,"name":"fluent","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\/#listItem","name":"I ran a transient flamelet (partially premixed combustion) case and forgot to do a statistical average of density, but I  averaged other key variables.  How can I get the time-averaged density without rerunning my transient simulation? Can I get it from the PDF tables?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\/#listItem","position":4,"name":"I ran a transient flamelet (partially premixed combustion) case and forgot to do a statistical average of density, but I  averaged other key variables.  How can I get the time-averaged density without rerunning my transient simulation? Can I get it from the PDF tables?","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","name":"fluent"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\/","name":"I ran a transient flamelet (partially premixed combustion) case and forgot to do a statistical average of density, but I averaged other key variables. How can I get the time-averaged density without rerunning my transient simulation? Can I get it from the PDF tables? | Ansys Knowledge","description":"The PDF table has an encrypted format that is proprietary, so no calls can be made to it to retrieve density. However, density can be estimated from the ideal gas law, or an approximation equivalent to that made in the PDF tables.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\/#breadcrumblist"},"datePublished":"2023-06-05T07:06:05+00:00","dateModified":"2023-07-31T12:30:17+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"I ran a transient flamelet (partially premixed combustion) case and forgot to do a statistical average of density, but I averaged other key variables. How can I get the time-averaged density without rerunning my transient simulation? Can I get it from the PDF tables? | Ansys Knowledge","og:description":"The PDF table has an encrypted format that is proprietary, so no calls can be made to it to retrieve density. However, density can be estimated from the ideal gas law, or an approximation equivalent to that made in the PDF tables.","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\/","article:published_time":"2023-06-05T07:06:05+00:00","article:modified_time":"2023-07-31T12:30:17+00:00","twitter:card":"summary_large_image","twitter:title":"I ran a transient flamelet (partially premixed combustion) case and forgot to do a statistical average of density, but I averaged other key variables. How can I get the time-averaged density without rerunning my transient simulation? Can I get it from the PDF tables? | Ansys Knowledge","twitter:description":"The PDF table has an encrypted format that is proprietary, so no calls can be made to it to retrieve density. However, density can be estimated from the ideal gas law, or an approximation equivalent to that made in the PDF tables."},"aioseo_meta_data":{"post_id":"171294","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-18 01:48:54","updated":"2026-07-30 05:42:15","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/\" title=\"fluent\">fluent<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tI ran a transient flamelet (partially premixed combustion) case and forgot to do a statistical average of density, but I  averaged other key variables.  How can I get the time-averaged density without rerunning my transient simulation? Can I get it from the PDF tables?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"fluent","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/"},{"label":"I ran a transient flamelet (partially premixed combustion) case and forgot to do a statistical average of density, but I  averaged other key variables.  How can I get the time-averaged density without rerunning my transient simulation? Can I get it from the PDF tables?","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-ran-a-transient-flamelet-partially-premixed-combustion-case-and-forgot-to-do-a-statistical-average-of-density-but-i-averaged-other-key-variables-how-can-i-get-the-time-averaged-density-without\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["2\/6\/2023 20:20"],"_bbp_forum_id":["27784"],"_bbp_author_ip":["209.182.204.162"],"_btv_view_count":["277"],"siebel_km_number":["2050475"],"product_version":["18.1"],"km_published_date":["2017-06-19T00:00:00.000Z"],"family":["Fluid Dynamics"],"application_name":["FLUENT"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/171294","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/171294\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=171294"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}