{"id":170659,"date":"2023-06-05T07:04:55","date_gmt":"2023-06-05T07:04:55","guid":{"rendered":"\/knowledge\/forums\/topic\/why-cant-i-get-stresses-after-a-response-spectrum\/"},"modified":"2023-07-31T12:33:31","modified_gmt":"2023-07-31T12:33:31","slug":"why-cant-i-get-stresses-after-a-response-spectrum","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/why-cant-i-get-stresses-after-a-response-spectrum\/","title":{"rendered":"Why can&#8217;t I get stresses after a response spectrum?"},"content":{"rendered":"<p>Somehow a setting to use &#8220;live stress&#8221; was set.  This setting only applies to static analysis and is used to postprocess a distributed solution without combining the slave results files together.  Because live stress is not available for response spectrum your stresses would not plot.  A workaround would be to duplicate the modal and response spectrum systems, change them to static systems, turn off live stress and then convert them back to modal and response spectrum.<\/p>\n","protected":false},"template":"","class_list":["post-170659","topic","type-topic","status-publish","hentry","topic-tag-17-2","topic-tag-mechanical","topic-tag-response-spectrum","topic-tag-structural-mechanics-response-spectrum","topic-tag-structural-dynamics","topic-tag-structural-mechanics"],"aioseo_notices":[],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["2\/6\/2023 20:20"],"_bbp_forum_id":["27792"],"_bbp_author_ip":["209.182.204.162"],"_btv_view_count":["943"],"siebel_km_number":["2045953"],"product_version":["17.2"],"km_published_date":["2016-12-29T00:00:00.000Z"],"family":["Structural Mechanics"],"application_name":["Mechanical"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/170659","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/170659\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=170659"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}