{"id":170608,"date":"2023-06-05T07:04:51","date_gmt":"2023-06-05T07:04:51","guid":{"rendered":"\/knowledge\/forums\/topic\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\/"},"modified":"2023-07-31T12:33:25","modified_gmt":"2023-07-31T12:33:25","slug":"iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\/","title":{"rendered":"IGES file generated by Ansys Mechanical APDL is imported with a scale factor 1000 in SCDM."},"content":{"rendered":"<p>By default, iges file exported from APDL comes in meter unit. For example, if one of the lines measure 30 units in APDL, the same dimension in IGES exported file will be read as 30m. But if you know that this dimension should be 30mm in iges file, then you need to first set appropriate units in APDL before exporting to iges. For setting mm units, set units to MPA using command &#8220;\/units,mpa&#8221;. This will change the unit system in APDL without changing the dimension values. So, the exported iges file will now have the value reported as 30mm.<\/p>\n","protected":false},"template":"","class_list":["post-170608","topic","type-topic","status-publish","hentry","topic-tag-18-1","topic-tag-general","topic-tag-mechanical-apdl","topic-tag-modeling-and-meshing","topic-tag-structural-mechanics"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"By default, iges file exported from APDL comes in meter unit. For example, if one of the lines measure 30 units in APDL, the same dimension in IGES exported file will be read as 30m. But if you know that this dimension should be 30mm in iges file, then you need to first set appropriate\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"IGES file generated by Ansys Mechanical APDL is imported with a scale factor 1000 in SCDM. | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"By default, iges file exported from APDL comes in meter unit. For example, if one of the lines measure 30 units in APDL, the same dimension in IGES exported file will be read as 30m. But if you know that this dimension should be 30mm in iges file, then you need to first set appropriate\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-06-05T07:04:51+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:33:25+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"IGES file generated by Ansys Mechanical APDL is imported with a scale factor 1000 in SCDM. | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"By default, iges file exported from APDL comes in meter unit. For example, if one of the lines measure 30 units in APDL, the same dimension in IGES exported file will be read as 30m. But if you know that this dimension should be 30mm in iges file, then you need to first set appropriate\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/structural-mechanics\\\/#listItem\",\"name\":\"structural-mechanics\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/structural-mechanics\\\/#listItem\",\"position\":3,\"name\":\"structural-mechanics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/structural-mechanics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\\\/#listItem\",\"name\":\"IGES file generated by Ansys Mechanical APDL is imported with a scale factor 1000 in SCDM.\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\\\/#listItem\",\"position\":4,\"name\":\"IGES file generated by Ansys Mechanical APDL is imported with a scale factor 1000 in SCDM.\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/structural-mechanics\\\/#listItem\",\"name\":\"structural-mechanics\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\\\/\",\"name\":\"IGES file generated by Ansys Mechanical APDL is imported with a scale factor 1000 in SCDM. | Ansys Knowledge\",\"description\":\"By default, iges file exported from APDL comes in meter unit. For example, if one of the lines measure 30 units in APDL, the same dimension in IGES exported file will be read as 30m. But if you know that this dimension should be 30mm in iges file, then you need to first set appropriate\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\\\/#breadcrumblist\"},\"datePublished\":\"2023-06-05T07:04:51+00:00\",\"dateModified\":\"2023-07-31T12:33:25+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"IGES file generated by Ansys Mechanical APDL is imported with a scale factor 1000 in SCDM. | Ansys Knowledge","description":"By default, iges file exported from APDL comes in meter unit. For example, if one of the lines measure 30 units in APDL, the same dimension in IGES exported file will be read as 30m. But if you know that this dimension should be 30mm in iges file, then you need to first set appropriate","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/#listItem","name":"structural-mechanics"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/#listItem","position":3,"name":"structural-mechanics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\/#listItem","name":"IGES file generated by Ansys Mechanical APDL is imported with a scale factor 1000 in SCDM."},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\/#listItem","position":4,"name":"IGES file generated by Ansys Mechanical APDL is imported with a scale factor 1000 in SCDM.","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/#listItem","name":"structural-mechanics"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\/","name":"IGES file generated by Ansys Mechanical APDL is imported with a scale factor 1000 in SCDM. | Ansys Knowledge","description":"By default, iges file exported from APDL comes in meter unit. For example, if one of the lines measure 30 units in APDL, the same dimension in IGES exported file will be read as 30m. But if you know that this dimension should be 30mm in iges file, then you need to first set appropriate","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\/#breadcrumblist"},"datePublished":"2023-06-05T07:04:51+00:00","dateModified":"2023-07-31T12:33:25+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"IGES file generated by Ansys Mechanical APDL is imported with a scale factor 1000 in SCDM. | Ansys Knowledge","og:description":"By default, iges file exported from APDL comes in meter unit. For example, if one of the lines measure 30 units in APDL, the same dimension in IGES exported file will be read as 30m. But if you know that this dimension should be 30mm in iges file, then you need to first set appropriate","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\/","article:published_time":"2023-06-05T07:04:51+00:00","article:modified_time":"2023-07-31T12:33:25+00:00","twitter:card":"summary_large_image","twitter:title":"IGES file generated by Ansys Mechanical APDL is imported with a scale factor 1000 in SCDM. | Ansys Knowledge","twitter:description":"By default, iges file exported from APDL comes in meter unit. For example, if one of the lines measure 30 units in APDL, the same dimension in IGES exported file will be read as 30m. But if you know that this dimension should be 30mm in iges file, then you need to first set appropriate"},"aioseo_meta_data":{"post_id":"170608","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-18 01:13:09","updated":"2026-07-30 00:33:14","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/\" title=\"structural-mechanics\">structural-mechanics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tIGES file generated by Ansys Mechanical APDL is imported with a scale factor 1000 in SCDM.\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"structural-mechanics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/"},{"label":"IGES file generated by Ansys Mechanical APDL is imported with a scale factor 1000 in SCDM.","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/iges-file-generated-by-ansys-mechanical-apdl-is-imported-with-a-scale-factor-1000-in-scdm\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["2\/6\/2023 20:20"],"_bbp_forum_id":["27789"],"_bbp_author_ip":["209.182.204.162"],"_btv_view_count":["2474"],"siebel_km_number":["2050974"],"product_version":["18.1"],"km_published_date":["2017-08-11T12:27:00.000Z"],"family":["Structural Mechanics"],"application_name":["Mechanical APDL"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/170608","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/170608\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=170608"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}