{"id":167420,"date":"2023-04-13T07:32:28","date_gmt":"2023-04-13T07:32:28","guid":{"rendered":"\/knowledge\/forums\/topic\/turbo-initialization-for-spinner-component-without-hub-r0\/"},"modified":"2023-07-31T12:28:12","modified_gmt":"2023-07-31T12:28:12","slug":"turbo-initialization-for-spinner-component-without-hub-r0","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/turbo-initialization-for-spinner-component-without-hub-r0\/","title":{"rendered":"Turbo Initialization for Spinner, Component without Hub (R=0)"},"content":{"rendered":"<p>For specific turbomachineries, there could be an inlet suction part without whole Hub turbo region (Spinner, Cone). In that case the default turbo initialization won\u2019t succeed. It needs to use the option From Line to represent the \u201cHub\u201d region.  Please see the attached document.<\/p>\n<p>Attachments:<br \/>\n1. <a href=https:\/\/ansys13.ansys.com\/KnowledgeArticles\/Phase-2A\/2063041\/2063041.pdf>2063041.pdf<\/a><\/p>\n","protected":false},"template":"","class_list":["post-167420","topic","type-topic","status-publish","hentry","topic-tag-2020-r1","topic-tag-cfd-post","topic-tag-fluid-dynamics","topic-tag-turbo-post-processing","topic-tag-turbomachinery"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"For specific turbomachineries, there could be an inlet suction part without whole Hub turbo region (Spinner, Cone). In that case the default turbo initialization won\u2019t succeed. It needs to use the option From Line to represent the \u201cHub\u201d region. Please see the attached document. Attachments: 1. 2063041.pdf\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/turbo-initialization-for-spinner-component-without-hub-r0\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Turbo Initialization for Spinner, Component without Hub (R=0) | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"For specific turbomachineries, there could be an inlet suction part without whole Hub turbo region (Spinner, Cone). In that case the default turbo initialization won\u2019t succeed. It needs to use the option From Line to represent the \u201cHub\u201d region. Please see the attached document. Attachments: 1. 2063041.pdf\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/turbo-initialization-for-spinner-component-without-hub-r0\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-04-13T07:32:28+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:28:12+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Turbo Initialization for Spinner, Component without Hub (R=0) | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"For specific turbomachineries, there could be an inlet suction part without whole Hub turbo region (Spinner, Cone). In that case the default turbo initialization won\u2019t succeed. It needs to use the option From Line to represent the \u201cHub\u201d region. Please see the attached document. Attachments: 1. 2063041.pdf\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/turbo-initialization-for-spinner-component-without-hub-r0\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/cfd-post\\\/#listItem\",\"name\":\"cfd-post\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/cfd-post\\\/#listItem\",\"position\":3,\"name\":\"cfd-post\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/cfd-post\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/turbo-initialization-for-spinner-component-without-hub-r0\\\/#listItem\",\"name\":\"Turbo Initialization for Spinner, Component without Hub (R=0)\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/turbo-initialization-for-spinner-component-without-hub-r0\\\/#listItem\",\"position\":4,\"name\":\"Turbo Initialization for Spinner, Component without Hub (R=0)\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/cfd-post\\\/#listItem\",\"name\":\"cfd-post\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/turbo-initialization-for-spinner-component-without-hub-r0\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/turbo-initialization-for-spinner-component-without-hub-r0\\\/\",\"name\":\"Turbo Initialization for Spinner, Component without Hub (R=0) | Ansys Knowledge\",\"description\":\"For specific turbomachineries, there could be an inlet suction part without whole Hub turbo region (Spinner, Cone). In that case the default turbo initialization won\\u2019t succeed. It needs to use the option From Line to represent the \\u201cHub\\u201d region. Please see the attached document. Attachments: 1. 2063041.pdf\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/turbo-initialization-for-spinner-component-without-hub-r0\\\/#breadcrumblist\"},\"datePublished\":\"2023-04-13T07:32:28+00:00\",\"dateModified\":\"2023-07-31T12:28:12+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Turbo Initialization for Spinner, Component without Hub (R=0) | Ansys Knowledge","description":"For specific turbomachineries, there could be an inlet suction part without whole Hub turbo region (Spinner, Cone). In that case the default turbo initialization won\u2019t succeed. It needs to use the option From Line to represent the \u201cHub\u201d region. Please see the attached document. Attachments: 1. 2063041.pdf","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/turbo-initialization-for-spinner-component-without-hub-r0\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/turbo-initialization-for-spinner-component-without-hub-r0\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfd-post\/#listItem","name":"cfd-post"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfd-post\/#listItem","position":3,"name":"cfd-post","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfd-post\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/turbo-initialization-for-spinner-component-without-hub-r0\/#listItem","name":"Turbo Initialization for Spinner, Component without Hub (R=0)"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/turbo-initialization-for-spinner-component-without-hub-r0\/#listItem","position":4,"name":"Turbo Initialization for Spinner, Component without Hub (R=0)","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfd-post\/#listItem","name":"cfd-post"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/turbo-initialization-for-spinner-component-without-hub-r0\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/turbo-initialization-for-spinner-component-without-hub-r0\/","name":"Turbo Initialization for Spinner, Component without Hub (R=0) | Ansys Knowledge","description":"For specific turbomachineries, there could be an inlet suction part without whole Hub turbo region (Spinner, Cone). In that case the default turbo initialization won\u2019t succeed. It needs to use the option From Line to represent the \u201cHub\u201d region. Please see the attached document. Attachments: 1. 2063041.pdf","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/turbo-initialization-for-spinner-component-without-hub-r0\/#breadcrumblist"},"datePublished":"2023-04-13T07:32:28+00:00","dateModified":"2023-07-31T12:28:12+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"Turbo Initialization for Spinner, Component without Hub (R=0) | Ansys Knowledge","og:description":"For specific turbomachineries, there could be an inlet suction part without whole Hub turbo region (Spinner, Cone). In that case the default turbo initialization won\u2019t succeed. It needs to use the option From Line to represent the \u201cHub\u201d region. Please see the attached document. Attachments: 1. 2063041.pdf","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/turbo-initialization-for-spinner-component-without-hub-r0\/","article:published_time":"2023-04-13T07:32:28+00:00","article:modified_time":"2023-07-31T12:28:12+00:00","twitter:card":"summary_large_image","twitter:title":"Turbo Initialization for Spinner, Component without Hub (R=0) | Ansys Knowledge","twitter:description":"For specific turbomachineries, there could be an inlet suction part without whole Hub turbo region (Spinner, Cone). In that case the default turbo initialization won\u2019t succeed. It needs to use the option From Line to represent the \u201cHub\u201d region. Please see the attached document. Attachments: 1. 2063041.pdf"},"aioseo_meta_data":{"post_id":"167420","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 23:48:54","updated":"2026-07-30 15:00:45","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfd-post\/\" title=\"cfd-post\">cfd-post<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tTurbo Initialization for Spinner, Component without Hub (R=0)\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"cfd-post","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfd-post\/"},{"label":"Turbo Initialization for Spinner, Component without Hub (R=0)","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/turbo-initialization-for-spinner-component-without-hub-r0\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["04-13-2023  20:20:01"],"_bbp_forum_id":["27796"],"_bbp_author_ip":["209.182.204.162"],"_btv_view_count":["990"],"siebel_km_number":["2063041"],"product_version":["2020 R1"],"km_published_date":["2020-07-16T00:00:00.000Z"],"family":["Fluid Dynamics"],"application_name":["CFD-Post"]},"test":"solution"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/167420","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/167420\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=167420"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}