{"id":167355,"date":"2023-04-13T07:32:22","date_gmt":"2023-04-13T07:32:22","guid":{"rendered":"\/knowledge\/forums\/topic\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\/"},"modified":"2023-07-31T12:35:09","modified_gmt":"2023-07-31T12:35:09","slug":"the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\/","title":{"rendered":"The customer has only one license for Professional NLS. ANSWAIT is set so that the remote solve should start once the license is freed. When he tries to solve remotely, the process ends without waiting until the license is available. Why is it not working as expected?"},"content":{"rendered":"<p>There is a problem in WB 11.0 sp1 where the ability to select the Professional NLS license for the remote solve is not enabled.  This is to be fixed in WB 12.0.  If the customer wants to always use the Professional NLS license for solving and is solving to a Windows machine, the attached AnsysUtils.cs file will allow this to work.  In the folder [RSMInstall]\/Config\/scripts\/, rename AnsysUtils.cs to AnsysUtilsorig.cs and use the attached AnsysUtils.cs file in its place.<\/p>\n<p>Attachments:<br \/>\n1. <a href=https:\/\/ansys13.ansys.com\/KnowledgeArticles\/Phase-2A\/739796\/739796.zip>739796.zip<\/a><\/p>\n","protected":false},"template":"","class_list":["post-167355","topic","type-topic","status-publish","hentry","topic-tag-4653","topic-tag-general","topic-tag-installation-licensing-systems","topic-tag-mechanical-apdl-f-ansys","topic-tag-rsm","topic-tag-systems-installation"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"There is a problem in WB 11.0 sp1 where the ability to select the Professional NLS license for the remote solve is not enabled. This is to be fixed in WB 12.0. If the customer wants to always use the Professional NLS license for solving and is solving to a Windows machine, the attached AnsysUtils.cs\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"The customer has only one license for Professional NLS. ANSWAIT is set so that the remote solve should start once the license is freed. When he tries to solve remotely, the process ends without waiting until the license is available. Why is it not working as expected? | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"There is a problem in WB 11.0 sp1 where the ability to select the Professional NLS license for the remote solve is not enabled. This is to be fixed in WB 12.0. If the customer wants to always use the Professional NLS license for solving and is solving to a Windows machine, the attached AnsysUtils.cs\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-04-13T07:32:22+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:35:09+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"The customer has only one license for Professional NLS. ANSWAIT is set so that the remote solve should start once the license is freed. When he tries to solve remotely, the process ends without waiting until the license is available. Why is it not working as expected? | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"There is a problem in WB 11.0 sp1 where the ability to select the Professional NLS license for the remote solve is not enabled. This is to be fixed in WB 12.0. If the customer wants to always use the Professional NLS license for solving and is solving to a Windows machine, the attached AnsysUtils.cs\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/rsm\\\/#listItem\",\"name\":\"rsm\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/rsm\\\/#listItem\",\"position\":3,\"name\":\"rsm\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/rsm\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\\\/#listItem\",\"name\":\"The customer has only one license for Professional NLS. ANSWAIT is set so that the remote solve should start once the license is freed. When he tries to solve remotely, the process ends without waiting until the license is available. Why is it not working as expected?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\\\/#listItem\",\"position\":4,\"name\":\"The customer has only one license for Professional NLS. ANSWAIT is set so that the remote solve should start once the license is freed. When he tries to solve remotely, the process ends without waiting until the license is available. Why is it not working as expected?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/rsm\\\/#listItem\",\"name\":\"rsm\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\\\/\",\"name\":\"The customer has only one license for Professional NLS. ANSWAIT is set so that the remote solve should start once the license is freed. When he tries to solve remotely, the process ends without waiting until the license is available. Why is it not working as expected? | Ansys Knowledge\",\"description\":\"There is a problem in WB 11.0 sp1 where the ability to select the Professional NLS license for the remote solve is not enabled. This is to be fixed in WB 12.0. If the customer wants to always use the Professional NLS license for solving and is solving to a Windows machine, the attached AnsysUtils.cs\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\\\/#breadcrumblist\"},\"datePublished\":\"2023-04-13T07:32:22+00:00\",\"dateModified\":\"2023-07-31T12:35:09+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"The customer has only one license for Professional NLS. ANSWAIT is set so that the remote solve should start once the license is freed. When he tries to solve remotely, the process ends without waiting until the license is available. Why is it not working as expected? | Ansys Knowledge","description":"There is a problem in WB 11.0 sp1 where the ability to select the Professional NLS license for the remote solve is not enabled. This is to be fixed in WB 12.0. If the customer wants to always use the Professional NLS license for solving and is solving to a Windows machine, the attached AnsysUtils.cs","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/rsm\/#listItem","name":"rsm"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/rsm\/#listItem","position":3,"name":"rsm","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/rsm\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\/#listItem","name":"The customer has only one license for Professional NLS. ANSWAIT is set so that the remote solve should start once the license is freed. When he tries to solve remotely, the process ends without waiting until the license is available. Why is it not working as expected?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\/#listItem","position":4,"name":"The customer has only one license for Professional NLS. ANSWAIT is set so that the remote solve should start once the license is freed. When he tries to solve remotely, the process ends without waiting until the license is available. Why is it not working as expected?","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/rsm\/#listItem","name":"rsm"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\/","name":"The customer has only one license for Professional NLS. ANSWAIT is set so that the remote solve should start once the license is freed. When he tries to solve remotely, the process ends without waiting until the license is available. Why is it not working as expected? | Ansys Knowledge","description":"There is a problem in WB 11.0 sp1 where the ability to select the Professional NLS license for the remote solve is not enabled. This is to be fixed in WB 12.0. If the customer wants to always use the Professional NLS license for solving and is solving to a Windows machine, the attached AnsysUtils.cs","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\/#breadcrumblist"},"datePublished":"2023-04-13T07:32:22+00:00","dateModified":"2023-07-31T12:35:09+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"The customer has only one license for Professional NLS. ANSWAIT is set so that the remote solve should start once the license is freed. When he tries to solve remotely, the process ends without waiting until the license is available. Why is it not working as expected? | Ansys Knowledge","og:description":"There is a problem in WB 11.0 sp1 where the ability to select the Professional NLS license for the remote solve is not enabled. This is to be fixed in WB 12.0. If the customer wants to always use the Professional NLS license for solving and is solving to a Windows machine, the attached AnsysUtils.cs","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\/","article:published_time":"2023-04-13T07:32:22+00:00","article:modified_time":"2023-07-31T12:35:09+00:00","twitter:card":"summary_large_image","twitter:title":"The customer has only one license for Professional NLS. ANSWAIT is set so that the remote solve should start once the license is freed. When he tries to solve remotely, the process ends without waiting until the license is available. Why is it not working as expected? | Ansys Knowledge","twitter:description":"There is a problem in WB 11.0 sp1 where the ability to select the Professional NLS license for the remote solve is not enabled. This is to be fixed in WB 12.0. If the customer wants to always use the Professional NLS license for solving and is solving to a Windows machine, the attached AnsysUtils.cs"},"aioseo_meta_data":{"post_id":"167355","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 23:45:10","updated":"2026-07-30 14:45:45","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/rsm\/\" title=\"rsm\">rsm<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tThe customer has only one license for Professional NLS. ANSWAIT is set so that the remote solve should start once the license is freed. When he tries to solve remotely, the process ends without waiting until the license is available. Why is it not working as expected?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"rsm","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/rsm\/"},{"label":"The customer has only one license for Professional NLS. ANSWAIT is set so that the remote solve should start once the license is freed. When he tries to solve remotely, the process ends without waiting until the license is available. Why is it not working as expected?","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-customer-has-only-one-license-for-professional-nls-answait-is-set-so-that-the-remote-solve-should-start-once-the-license-is-freed-when-he-tries-to-solve-remotely-the-process-ends-without-waitin\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["04-13-2023  20:20:01"],"_bbp_forum_id":["153867"],"_bbp_author_ip":["209.182.204.162"],"_btv_view_count":["1107"],"siebel_km_number":["739796"],"product_version":["11"],"km_published_date":["2008-04-17T00:00:00.000Z"],"family":["Installation\/Licensing\/Systems"],"application_name":["Mechanical APDL (f. ANSYS)"]},"test":"solution"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/167355","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/167355\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=167355"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}