{"id":167230,"date":"2023-04-05T14:33:12","date_gmt":"2023-04-05T14:33:12","guid":{"rendered":"\/knowledge\/forums\/topic\/which-size-function-should-i-use-when-creating-a-cfd-mesh\/"},"modified":"2023-07-31T12:28:02","modified_gmt":"2023-07-31T12:28:02","slug":"which-size-function-should-i-use-when-creating-a-cfd-mesh","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/which-size-function-should-i-use-when-creating-a-cfd-mesh\/","title":{"rendered":"Which size function should I use when creating a CFD mesh?"},"content":{"rendered":"<p>In Workbench meshing, \u2018Size Function\u2019 refer to automatic refinement algorithms, that can be invoked to properly mesh domains based on their topology. Several options are listed:   -Adaptive: should not be used for CFD meshes -Curvature: refine curved zones, based on a provided \u2018Curvature Normal Angle\u2019 -Proximity: populate small gaps with provided \u2018Number Cells Across Gaps\u2019 -Curvature &#038; proximity: combine two previous algorithms -Uniform: domain is meshed with a constant size, refinement are only local ones  For CFD meshes, activate \u2018Curvature\u2019 whenever curved areas exist in your model. You might add \u2018Proximity\u2019 if you have small gaps to be refined, but it may prove very costly in terms of meshing time. In this case you have three options:   -Keep only global \u2018Curvature\u2019, and activate \u2018Proximity\u2019 for local sizings where needed -Keep only global \u2018Curvature\u2019, and create local \u2018Fixed\u2019 sizings with smaller size -Use \u2018Fixed\u2019 global size function and create local sizings to refine curved areas and gaps where needed<\/p>\n","protected":false},"template":"","class_list":["post-167230","topic","type-topic","status-publish","hentry","topic-tag-4391","topic-tag-fluid-dynamics","topic-tag-general","topic-tag-meshing"],"aioseo_notices":[],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["5\/4\/2023 20:20"],"_bbp_forum_id":["27796"],"_bbp_author_ip":["209.182.204.162"],"_btv_view_count":["945"],"siebel_km_number":["2054389"],"product_version":["19"],"km_published_date":["2018-04-27T00:00:00.000Z"],"family":["Fluid Dynamics"],"application_name":["Meshing"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/167230","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/167230\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=167230"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}