{"id":167203,"date":"2023-04-05T14:33:09","date_gmt":"2023-04-05T14:33:09","guid":{"rendered":"\/knowledge\/forums\/topic\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\/"},"modified":"2023-07-31T12:32:31","modified_gmt":"2023-07-31T12:32:31","slug":"for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\/","title":{"rendered":"For FLUID116 can mass flow rate be specified using a tabular load that is spatially varying (SFE,,,HFLUX)?"},"content":{"rendered":"<p>No,  for FLUID116 the thermal boundary condition of flow rate is only supported for tabular loads with TIME as the primary variable.  See Table 2.11 in the Thermal Analysis Guide or this ANSYS Help link:  help\/ans_the\/Hlp_G_THE2_6.html#thetabbctlm6700<\/p>\n","protected":false},"template":"","class_list":["post-167203","topic","type-topic","status-publish","hentry","topic-tag-18-2","topic-tag-apdl","topic-tag-mechanical-apdl","topic-tag-static","topic-tag-structural-and-thermal","topic-tag-structural-mechanics"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"No, for FLUID116 the thermal boundary condition of flow rate is only supported for tabular loads with TIME as the primary variable. See Table 2.11 in the Thermal Analysis Guide or this ANSYS Help link: help\/ans_the\/Hlp_G_THE2_6.html#thetabbctlm6700\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"For FLUID116 can mass flow rate be specified using a tabular load that is spatially varying (SFE,,,HFLUX)? | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"No, for FLUID116 the thermal boundary condition of flow rate is only supported for tabular loads with TIME as the primary variable. See Table 2.11 in the Thermal Analysis Guide or this ANSYS Help link: help\/ans_the\/Hlp_G_THE2_6.html#thetabbctlm6700\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-04-05T14:33:09+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:32:31+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"For FLUID116 can mass flow rate be specified using a tabular load that is spatially varying (SFE,,,HFLUX)? | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"No, for FLUID116 the thermal boundary condition of flow rate is only supported for tabular loads with TIME as the primary variable. See Table 2.11 in the Thermal Analysis Guide or this ANSYS Help link: help\/ans_the\/Hlp_G_THE2_6.html#thetabbctlm6700\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/structural-mechanics\\\/#listItem\",\"name\":\"structural-mechanics\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/structural-mechanics\\\/#listItem\",\"position\":3,\"name\":\"structural-mechanics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/structural-mechanics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\\\/#listItem\",\"name\":\"For FLUID116 can mass flow rate be specified using a tabular load that is spatially varying (SFE,,,HFLUX)?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\\\/#listItem\",\"position\":4,\"name\":\"For FLUID116 can mass flow rate be specified using a tabular load that is spatially varying (SFE,,,HFLUX)?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/structural-mechanics\\\/#listItem\",\"name\":\"structural-mechanics\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\\\/\",\"name\":\"For FLUID116 can mass flow rate be specified using a tabular load that is spatially varying (SFE,,,HFLUX)? | Ansys Knowledge\",\"description\":\"No, for FLUID116 the thermal boundary condition of flow rate is only supported for tabular loads with TIME as the primary variable. See Table 2.11 in the Thermal Analysis Guide or this ANSYS Help link: help\\\/ans_the\\\/Hlp_G_THE2_6.html#thetabbctlm6700\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\\\/#breadcrumblist\"},\"datePublished\":\"2023-04-05T14:33:09+00:00\",\"dateModified\":\"2023-07-31T12:32:31+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"For FLUID116 can mass flow rate be specified using a tabular load that is spatially varying (SFE,,,HFLUX)? | Ansys Knowledge","description":"No, for FLUID116 the thermal boundary condition of flow rate is only supported for tabular loads with TIME as the primary variable. See Table 2.11 in the Thermal Analysis Guide or this ANSYS Help link: help\/ans_the\/Hlp_G_THE2_6.html#thetabbctlm6700","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/#listItem","name":"structural-mechanics"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/#listItem","position":3,"name":"structural-mechanics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\/#listItem","name":"For FLUID116 can mass flow rate be specified using a tabular load that is spatially varying (SFE,,,HFLUX)?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\/#listItem","position":4,"name":"For FLUID116 can mass flow rate be specified using a tabular load that is spatially varying (SFE,,,HFLUX)?","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/#listItem","name":"structural-mechanics"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\/","name":"For FLUID116 can mass flow rate be specified using a tabular load that is spatially varying (SFE,,,HFLUX)? | Ansys Knowledge","description":"No, for FLUID116 the thermal boundary condition of flow rate is only supported for tabular loads with TIME as the primary variable. See Table 2.11 in the Thermal Analysis Guide or this ANSYS Help link: help\/ans_the\/Hlp_G_THE2_6.html#thetabbctlm6700","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\/#breadcrumblist"},"datePublished":"2023-04-05T14:33:09+00:00","dateModified":"2023-07-31T12:32:31+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"For FLUID116 can mass flow rate be specified using a tabular load that is spatially varying (SFE,,,HFLUX)? | Ansys Knowledge","og:description":"No, for FLUID116 the thermal boundary condition of flow rate is only supported for tabular loads with TIME as the primary variable. See Table 2.11 in the Thermal Analysis Guide or this ANSYS Help link: help\/ans_the\/Hlp_G_THE2_6.html#thetabbctlm6700","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\/","article:published_time":"2023-04-05T14:33:09+00:00","article:modified_time":"2023-07-31T12:32:31+00:00","twitter:card":"summary_large_image","twitter:title":"For FLUID116 can mass flow rate be specified using a tabular load that is spatially varying (SFE,,,HFLUX)? | Ansys Knowledge","twitter:description":"No, for FLUID116 the thermal boundary condition of flow rate is only supported for tabular loads with TIME as the primary variable. See Table 2.11 in the Thermal Analysis Guide or this ANSYS Help link: help\/ans_the\/Hlp_G_THE2_6.html#thetabbctlm6700"},"aioseo_meta_data":{"post_id":"167203","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 23:38:23","updated":"2026-07-29 23:05:25","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/\" title=\"structural-mechanics\">structural-mechanics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tFor FLUID116 can mass flow rate be specified using a tabular load that is spatially varying (SFE,,,HFLUX)?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"structural-mechanics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/"},{"label":"For FLUID116 can mass flow rate be specified using a tabular load that is spatially varying (SFE,,,HFLUX)?","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/for-fluid116-can-mass-flow-rate-be-specified-using-a-tabular-load-that-is-spatially-varying-sfehflux\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["5\/4\/2023 20:20"],"_bbp_forum_id":["27795"],"_bbp_author_ip":["209.182.204.162"],"_btv_view_count":["911"],"siebel_km_number":["2051307"],"product_version":["18.2"],"km_published_date":["2017-09-15T00:00:00.000Z"],"family":["Structural Mechanics"],"application_name":["Mechanical APDL"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/167203","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/167203\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=167203"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}