{"id":167136,"date":"2023-04-05T14:33:00","date_gmt":"2023-04-05T14:33:00","guid":{"rendered":"\/knowledge\/forums\/topic\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\/"},"modified":"2023-07-31T12:27:58","modified_gmt":"2023-07-31T12:27:58","slug":"i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\/","title":{"rendered":"I cannot see the y+ \/ yplus variable in CFD Post, even after selecting it in &#8216;Data File Quantities&#8217;"},"content":{"rendered":"<p>CFD-Post was modified in version 18.0 to avoid loading some Fluent variables from .dat files, including yplus, as they were not guaranteed to be correct.  This is documented in the CFD Post help version 18.2 under &#8220;7.15.8. Fluent Files&#8221;. The recommended way to view such variables now is to explicitly export them to a .cdat file instead or to post-process in Fluent.<\/p>\n","protected":false},"template":"","class_list":["post-167136","topic","type-topic","status-publish","hentry","topic-tag-18-2","topic-tag-cfd-post","topic-tag-fluid-dynamics","topic-tag-general"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"CFD-Post was modified in version 18.0 to avoid loading some Fluent variables from .dat files, including yplus, as they were not guaranteed to be correct. This is documented in the CFD Post help version 18.2 under &quot;7.15.8. Fluent Files&quot;. The recommended way to view such variables now is to explicitly export them to a .cdat\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"I cannot see the y+ \/ yplus variable in CFD Post, even after selecting it in \u2018Data File Quantities\u2019 | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"CFD-Post was modified in version 18.0 to avoid loading some Fluent variables from .dat files, including yplus, as they were not guaranteed to be correct. This is documented in the CFD Post help version 18.2 under &quot;7.15.8. Fluent Files&quot;. The recommended way to view such variables now is to explicitly export them to a .cdat\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-04-05T14:33:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:27:58+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"I cannot see the y+ \/ yplus variable in CFD Post, even after selecting it in \u2018Data File Quantities\u2019 | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"CFD-Post was modified in version 18.0 to avoid loading some Fluent variables from .dat files, including yplus, as they were not guaranteed to be correct. This is documented in the CFD Post help version 18.2 under &quot;7.15.8. Fluent Files&quot;. The recommended way to view such variables now is to explicitly export them to a .cdat\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/cfd-post\\\/#listItem\",\"name\":\"cfd-post\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/cfd-post\\\/#listItem\",\"position\":3,\"name\":\"cfd-post\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/cfd-post\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\\\/#listItem\",\"name\":\"I cannot see the y+ \\\/ yplus variable in CFD Post, even after selecting it in &#8216;Data File Quantities&#8217;\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\\\/#listItem\",\"position\":4,\"name\":\"I cannot see the y+ \\\/ yplus variable in CFD Post, even after selecting it in &#8216;Data File Quantities&#8217;\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/cfd-post\\\/#listItem\",\"name\":\"cfd-post\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\\\/\",\"name\":\"I cannot see the y+ \\\/ yplus variable in CFD Post, even after selecting it in \\u2018Data File Quantities\\u2019 | Ansys Knowledge\",\"description\":\"CFD-Post was modified in version 18.0 to avoid loading some Fluent variables from .dat files, including yplus, as they were not guaranteed to be correct. This is documented in the CFD Post help version 18.2 under \\\"7.15.8. Fluent Files\\\". The recommended way to view such variables now is to explicitly export them to a .cdat\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\\\/#breadcrumblist\"},\"datePublished\":\"2023-04-05T14:33:00+00:00\",\"dateModified\":\"2023-07-31T12:27:58+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"I cannot see the y+ \/ yplus variable in CFD Post, even after selecting it in \u2018Data File Quantities\u2019 | Ansys Knowledge","description":"CFD-Post was modified in version 18.0 to avoid loading some Fluent variables from .dat files, including yplus, as they were not guaranteed to be correct. This is documented in the CFD Post help version 18.2 under \"7.15.8. Fluent Files\". The recommended way to view such variables now is to explicitly export them to a .cdat","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfd-post\/#listItem","name":"cfd-post"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfd-post\/#listItem","position":3,"name":"cfd-post","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfd-post\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\/#listItem","name":"I cannot see the y+ \/ yplus variable in CFD Post, even after selecting it in &#8216;Data File Quantities&#8217;"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\/#listItem","position":4,"name":"I cannot see the y+ \/ yplus variable in CFD Post, even after selecting it in &#8216;Data File Quantities&#8217;","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfd-post\/#listItem","name":"cfd-post"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\/","name":"I cannot see the y+ \/ yplus variable in CFD Post, even after selecting it in \u2018Data File Quantities\u2019 | Ansys Knowledge","description":"CFD-Post was modified in version 18.0 to avoid loading some Fluent variables from .dat files, including yplus, as they were not guaranteed to be correct. This is documented in the CFD Post help version 18.2 under \"7.15.8. Fluent Files\". The recommended way to view such variables now is to explicitly export them to a .cdat","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\/#breadcrumblist"},"datePublished":"2023-04-05T14:33:00+00:00","dateModified":"2023-07-31T12:27:58+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"I cannot see the y+ \/ yplus variable in CFD Post, even after selecting it in \u2018Data File Quantities\u2019 | Ansys Knowledge","og:description":"CFD-Post was modified in version 18.0 to avoid loading some Fluent variables from .dat files, including yplus, as they were not guaranteed to be correct. This is documented in the CFD Post help version 18.2 under &quot;7.15.8. Fluent Files&quot;. The recommended way to view such variables now is to explicitly export them to a .cdat","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\/","article:published_time":"2023-04-05T14:33:00+00:00","article:modified_time":"2023-07-31T12:27:58+00:00","twitter:card":"summary_large_image","twitter:title":"I cannot see the y+ \/ yplus variable in CFD Post, even after selecting it in \u2018Data File Quantities\u2019 | Ansys Knowledge","twitter:description":"CFD-Post was modified in version 18.0 to avoid loading some Fluent variables from .dat files, including yplus, as they were not guaranteed to be correct. This is documented in the CFD Post help version 18.2 under &quot;7.15.8. Fluent Files&quot;. The recommended way to view such variables now is to explicitly export them to a .cdat"},"aioseo_meta_data":{"post_id":"167136","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 23:35:09","updated":"2026-07-29 22:29:43","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfd-post\/\" title=\"cfd-post\">cfd-post<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tI cannot see the y+ \/ yplus variable in CFD Post, even after selecting it in \u2018Data File Quantities\u2019\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"cfd-post","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfd-post\/"},{"label":"I cannot see the y+ \/ yplus variable in CFD Post, even after selecting it in &#8216;Data File Quantities&#8217;","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/i-cannot-see-the-y-yplus-variable-in-cfd-post-even-after-selecting-it-in-data-file-quantities\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["5\/4\/2023 20:20"],"_bbp_forum_id":["27796"],"_bbp_author_ip":["209.182.204.162"],"_btv_view_count":["1635"],"siebel_km_number":["2055804"],"product_version":["18.2"],"km_published_date":["2018-08-08T00:00:00.000Z"],"family":["Fluid Dynamics"],"application_name":["CFD-Post"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/167136","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/167136\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=167136"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}