{"id":167061,"date":"2023-04-05T14:32:48","date_gmt":"2023-04-05T14:32:48","guid":{"rendered":"\/knowledge\/forums\/topic\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\/"},"modified":"2023-07-31T12:32:24","modified_gmt":"2023-07-31T12:32:24","slug":"on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\/","title":{"rendered":"On a Pre-Stressed Modal in which the Static Structural has multiple steps, choosing an intermediate pre-stress step results in questions marks and a restart related error"},"content":{"rendered":"<p>This is because by default, the pre-stressed modal analysis is run as a restart analysis from the preceding static analysis and by default, the restart points are save only at the last time step. To fix this the user needs to go to Analysis Settings in the Static Structural analysis, find Restart Controls and change the Generate Restart Points to Manual and set Load Step to All.<\/p>\n","protected":false},"template":"","class_list":["post-167061","topic","type-topic","status-publish","hentry","topic-tag-18-2","topic-tag-mechanical","topic-tag-modal-harmonic-response","topic-tag-structural-dynamics","topic-tag-structural-mechanics"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"This is because by default, the pre-stressed modal analysis is run as a restart analysis from the preceding static analysis and by default, the restart points are save only at the last time step. To fix this the user needs to go to Analysis Settings in the Static Structural analysis, find Restart Controls and change\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"On a Pre-Stressed Modal in which the Static Structural has multiple steps, choosing an intermediate pre-stress step results in questions marks and a restart related error | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"This is because by default, the pre-stressed modal analysis is run as a restart analysis from the preceding static analysis and by default, the restart points are save only at the last time step. To fix this the user needs to go to Analysis Settings in the Static Structural analysis, find Restart Controls and change\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-04-05T14:32:48+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:32:24+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"On a Pre-Stressed Modal in which the Static Structural has multiple steps, choosing an intermediate pre-stress step results in questions marks and a restart related error | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"This is because by default, the pre-stressed modal analysis is run as a restart analysis from the preceding static analysis and by default, the restart points are save only at the last time step. To fix this the user needs to go to Analysis Settings in the Static Structural analysis, find Restart Controls and change\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/structural-mechanics\\\/#listItem\",\"name\":\"structural-mechanics\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/structural-mechanics\\\/#listItem\",\"position\":3,\"name\":\"structural-mechanics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/structural-mechanics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\\\/#listItem\",\"name\":\"On a Pre-Stressed Modal in which the Static Structural has multiple steps, choosing an intermediate pre-stress step results in questions marks and a restart related error\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\\\/#listItem\",\"position\":4,\"name\":\"On a Pre-Stressed Modal in which the Static Structural has multiple steps, choosing an intermediate pre-stress step results in questions marks and a restart related error\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/structural-mechanics\\\/#listItem\",\"name\":\"structural-mechanics\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\\\/\",\"name\":\"On a Pre-Stressed Modal in which the Static Structural has multiple steps, choosing an intermediate pre-stress step results in questions marks and a restart related error | Ansys Knowledge\",\"description\":\"This is because by default, the pre-stressed modal analysis is run as a restart analysis from the preceding static analysis and by default, the restart points are save only at the last time step. To fix this the user needs to go to Analysis Settings in the Static Structural analysis, find Restart Controls and change\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\\\/#breadcrumblist\"},\"datePublished\":\"2023-04-05T14:32:48+00:00\",\"dateModified\":\"2023-07-31T12:32:24+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"On a Pre-Stressed Modal in which the Static Structural has multiple steps, choosing an intermediate pre-stress step results in questions marks and a restart related error | Ansys Knowledge","description":"This is because by default, the pre-stressed modal analysis is run as a restart analysis from the preceding static analysis and by default, the restart points are save only at the last time step. To fix this the user needs to go to Analysis Settings in the Static Structural analysis, find Restart Controls and change","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/#listItem","name":"structural-mechanics"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/#listItem","position":3,"name":"structural-mechanics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\/#listItem","name":"On a Pre-Stressed Modal in which the Static Structural has multiple steps, choosing an intermediate pre-stress step results in questions marks and a restart related error"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\/#listItem","position":4,"name":"On a Pre-Stressed Modal in which the Static Structural has multiple steps, choosing an intermediate pre-stress step results in questions marks and a restart related error","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/#listItem","name":"structural-mechanics"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\/","name":"On a Pre-Stressed Modal in which the Static Structural has multiple steps, choosing an intermediate pre-stress step results in questions marks and a restart related error | Ansys Knowledge","description":"This is because by default, the pre-stressed modal analysis is run as a restart analysis from the preceding static analysis and by default, the restart points are save only at the last time step. To fix this the user needs to go to Analysis Settings in the Static Structural analysis, find Restart Controls and change","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\/#breadcrumblist"},"datePublished":"2023-04-05T14:32:48+00:00","dateModified":"2023-07-31T12:32:24+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"On a Pre-Stressed Modal in which the Static Structural has multiple steps, choosing an intermediate pre-stress step results in questions marks and a restart related error | Ansys Knowledge","og:description":"This is because by default, the pre-stressed modal analysis is run as a restart analysis from the preceding static analysis and by default, the restart points are save only at the last time step. To fix this the user needs to go to Analysis Settings in the Static Structural analysis, find Restart Controls and change","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\/","article:published_time":"2023-04-05T14:32:48+00:00","article:modified_time":"2023-07-31T12:32:24+00:00","twitter:card":"summary_large_image","twitter:title":"On a Pre-Stressed Modal in which the Static Structural has multiple steps, choosing an intermediate pre-stress step results in questions marks and a restart related error | Ansys Knowledge","twitter:description":"This is because by default, the pre-stressed modal analysis is run as a restart analysis from the preceding static analysis and by default, the restart points are save only at the last time step. To fix this the user needs to go to Analysis Settings in the Static Structural analysis, find Restart Controls and change"},"aioseo_meta_data":{"post_id":"167061","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 23:30:54","updated":"2026-07-29 21:37:05","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/\" title=\"structural-mechanics\">structural-mechanics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tOn a Pre-Stressed Modal in which the Static Structural has multiple steps, choosing an intermediate pre-stress step results in questions marks and a restart related error\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"structural-mechanics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/structural-mechanics\/"},{"label":"On a Pre-Stressed Modal in which the Static Structural has multiple steps, choosing an intermediate pre-stress step results in questions marks and a restart related error","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/on-a-pre-stressed-modal-in-which-the-static-structural-has-multiple-steps-choosing-an-intermediate-pre-stress-step-results-in-questions-marks-and-a-restart-related-error\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["5\/4\/2023 20:20"],"_bbp_forum_id":["27792"],"_bbp_author_ip":["209.182.204.162"],"_btv_view_count":["3728"],"siebel_km_number":["2052986"],"product_version":["18.2"],"km_published_date":["2018-01-17T00:00:00.000Z"],"family":["Structural Mechanics"],"application_name":["Mechanical"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/167061","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/167061\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=167061"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}