{"id":166574,"date":"2023-03-17T14:15:34","date_gmt":"2023-03-17T14:15:34","guid":{"rendered":"\/knowledge\/forums\/topic\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\/"},"modified":"2023-03-17T14:15:34","modified_gmt":"2023-03-17T14:15:34","slug":"maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\/","title":{"rendered":"Maxwell results deleted on project save. Running Maxwell inside ANSYS Workbench and using the background white space properties update option, Submit to Remote Solve Manager."},"content":{"rendered":"<p>A Maxwell calculation run inside Workbench using the background white space properties option: &#8220;Submit to Remote Solve Manager&#8221; will delete all Maxwell results files when the project is saved.   This is how the software is currently designed to work when using the ANSYS Remote Solve Option (RSM). Only the Design Point\/DX output data is retained.  If you want to retain the Maxwell results files, change the background white space properties option to: &#8220;Run in Foreground&#8221;.<\/p>\n","protected":false},"template":"","class_list":["post-166574","topic","type-topic","status-publish","hentry","topic-tag-2019-r1","topic-tag-electromagnetics-electronics","topic-tag-general-maxwell","topic-tag-low-frequency-electromagnetics","topic-tag-maxwell","topic-tag-static-fields","topic-tag-workbench"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"A Maxwell calculation run inside Workbench using the background white space properties option: &quot;Submit to Remote Solve Manager&quot; will delete all Maxwell results files when the project is saved. This is how the software is currently designed to work when using the ANSYS Remote Solve Option (RSM). Only the Design Point\/DX output data is retained.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Maxwell results deleted on project save. Running Maxwell inside ANSYS Workbench and using the background white space properties update option, Submit to Remote Solve Manager. | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"A Maxwell calculation run inside Workbench using the background white space properties option: &quot;Submit to Remote Solve Manager&quot; will delete all Maxwell results files when the project is saved. This is how the software is currently designed to work when using the ANSYS Remote Solve Option (RSM). Only the Design Point\/DX output data is retained.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-03-17T14:15:34+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-03-17T14:15:34+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Maxwell results deleted on project save. Running Maxwell inside ANSYS Workbench and using the background white space properties update option, Submit to Remote Solve Manager. | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"A Maxwell calculation run inside Workbench using the background white space properties option: &quot;Submit to Remote Solve Manager&quot; will delete all Maxwell results files when the project is saved. This is how the software is currently designed to work when using the ANSYS Remote Solve Option (RSM). Only the Design Point\/DX output data is retained.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/workbench\\\/#listItem\",\"name\":\"workbench\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/workbench\\\/#listItem\",\"position\":3,\"name\":\"workbench\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/workbench\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\\\/#listItem\",\"name\":\"Maxwell results deleted on project save. Running Maxwell inside ANSYS Workbench and using the background white space properties update option, Submit to Remote Solve Manager.\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\\\/#listItem\",\"position\":4,\"name\":\"Maxwell results deleted on project save. Running Maxwell inside ANSYS Workbench and using the background white space properties update option, Submit to Remote Solve Manager.\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/workbench\\\/#listItem\",\"name\":\"workbench\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\\\/\",\"name\":\"Maxwell results deleted on project save. Running Maxwell inside ANSYS Workbench and using the background white space properties update option, Submit to Remote Solve Manager. | Ansys Knowledge\",\"description\":\"A Maxwell calculation run inside Workbench using the background white space properties option: \\\"Submit to Remote Solve Manager\\\" will delete all Maxwell results files when the project is saved. This is how the software is currently designed to work when using the ANSYS Remote Solve Option (RSM). Only the Design Point\\\/DX output data is retained.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\\\/#breadcrumblist\"},\"datePublished\":\"2023-03-17T14:15:34+00:00\",\"dateModified\":\"2023-03-17T14:15:34+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Maxwell results deleted on project save. Running Maxwell inside ANSYS Workbench and using the background white space properties update option, Submit to Remote Solve Manager. | Ansys Knowledge","description":"A Maxwell calculation run inside Workbench using the background white space properties option: \"Submit to Remote Solve Manager\" will delete all Maxwell results files when the project is saved. This is how the software is currently designed to work when using the ANSYS Remote Solve Option (RSM). Only the Design Point\/DX output data is retained.","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/workbench\/#listItem","name":"workbench"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/workbench\/#listItem","position":3,"name":"workbench","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/workbench\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\/#listItem","name":"Maxwell results deleted on project save. Running Maxwell inside ANSYS Workbench and using the background white space properties update option, Submit to Remote Solve Manager."},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\/#listItem","position":4,"name":"Maxwell results deleted on project save. Running Maxwell inside ANSYS Workbench and using the background white space properties update option, Submit to Remote Solve Manager.","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/workbench\/#listItem","name":"workbench"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\/","name":"Maxwell results deleted on project save. Running Maxwell inside ANSYS Workbench and using the background white space properties update option, Submit to Remote Solve Manager. | Ansys Knowledge","description":"A Maxwell calculation run inside Workbench using the background white space properties option: \"Submit to Remote Solve Manager\" will delete all Maxwell results files when the project is saved. This is how the software is currently designed to work when using the ANSYS Remote Solve Option (RSM). Only the Design Point\/DX output data is retained.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\/#breadcrumblist"},"datePublished":"2023-03-17T14:15:34+00:00","dateModified":"2023-03-17T14:15:34+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"Maxwell results deleted on project save. Running Maxwell inside ANSYS Workbench and using the background white space properties update option, Submit to Remote Solve Manager. | Ansys Knowledge","og:description":"A Maxwell calculation run inside Workbench using the background white space properties option: &quot;Submit to Remote Solve Manager&quot; will delete all Maxwell results files when the project is saved. This is how the software is currently designed to work when using the ANSYS Remote Solve Option (RSM). Only the Design Point\/DX output data is retained.","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\/","article:published_time":"2023-03-17T14:15:34+00:00","article:modified_time":"2023-03-17T14:15:34+00:00","twitter:card":"summary_large_image","twitter:title":"Maxwell results deleted on project save. Running Maxwell inside ANSYS Workbench and using the background white space properties update option, Submit to Remote Solve Manager. | Ansys Knowledge","twitter:description":"A Maxwell calculation run inside Workbench using the background white space properties option: &quot;Submit to Remote Solve Manager&quot; will delete all Maxwell results files when the project is saved. This is how the software is currently designed to work when using the ANSYS Remote Solve Option (RSM). Only the Design Point\/DX output data is retained."},"aioseo_meta_data":{"post_id":"166574","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 23:10:04","updated":"2026-07-29 18:45:41","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/workbench\/\" title=\"workbench\">workbench<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tMaxwell results deleted on project save. Running Maxwell inside ANSYS Workbench and using the background white space properties update option, Submit to Remote Solve Manager.\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"workbench","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/workbench\/"},{"label":"Maxwell results deleted on project save. Running Maxwell inside ANSYS Workbench and using the background white space properties update option, Submit to Remote Solve Manager.","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/maxwell-results-deleted-on-project-save-running-maxwell-inside-ansys-workbench-and-using-the-background-white-space-properties-update-option-submit-to-remote-solve-manager\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"siebel_km_number":[""],"_bbp_last_active_time":["3-17-2023  20:20:00"],"_bbp_forum_id":["27819"],"_bbp_author_ip":["23.56.168.180"],"_btv_view_count":["2013"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/166574","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/166574\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=166574"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}