{"id":166059,"date":"2023-03-17T13:10:58","date_gmt":"2023-03-17T13:10:58","guid":{"rendered":"\/knowledge\/forums\/topic\/how-do-i-check-y-3\/"},"modified":"2023-07-31T12:27:14","modified_gmt":"2023-07-31T12:27:14","slug":"how-do-i-check-y-3","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-do-i-check-y-3\/","title":{"rendered":"How do I check Y+?"},"content":{"rendered":"<p>For a 3D Case 1. Click Display-> Contour-> Turbulance-> Y Plus of the surface of interest. 2. Turn off Node Value display. 3. You can now check if the minimum and maximum Y+ forms an appropriate range   For a 2D Case 1.Click Display-> Contour-> Turbulence-> Y Plus. You do not need to select any Surfaces  2.Turn off Node Value display  3.You can now check the value of Y+ (note to ignore the value of Y+ except for cells adjacent to the wall).  In a fine mesh, a recommended value of 1 for Y+ in a fine mesh, and 30 to 500 for a wall function. <\/p>\n<p>Attachments:<br \/>\n1. <a href=https:\/\/ansys13.ansys.com\/KnowledgeArticles\/Phase-1\/2041852\/2041852.pdf>2041852.pdf<\/a><\/p>\n","protected":false},"template":"","class_list":["post-166059","topic","type-topic","status-publish","hentry","topic-tag-4431","topic-tag-fluent","topic-tag-fluid-dynamics","topic-tag-general","topic-tag-post-processing","topic-tag-postprocess","topic-tag-turbulence"],"aioseo_notices":[],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["3-15-2023  20:20:55"],"_bbp_forum_id":["27796"],"_bbp_author_ip":["23.56.168.180"],"_btv_view_count":["9968"],"siebel_km_number":["2041852"],"product_version":["17"],"km_published_date":["2016-04-02T01:54:08.000Z"],"family":["Fluid Dynamics"],"application_name":["FLUENT"],"_edit_lock":["1704983926:2"]},"test":"solution"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/166059","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":1,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/166059\/revisions"}],"predecessor-version":[{"id":181129,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/166059\/revisions\/181129"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=166059"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}