{"id":165874,"date":"2023-03-17T13:10:29","date_gmt":"2023-03-17T13:10:29","guid":{"rendered":"\/knowledge\/forums\/topic\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\/"},"modified":"2023-07-31T12:26:54","modified_gmt":"2023-07-31T12:26:54","slug":"how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\/","title":{"rendered":"How to execute commands in ANSYS Fluent after a calculation has converged?"},"content":{"rendered":"<p>When you want to execute text commands, macros, journals or Scheme scripts after a calculation is fin-ished, you can use the case modification feature that is described in the ANSYS Fluent 2019 R2 User\u2019s Guide, chapter 37.18. Automatic Initialization of the Solution and Case Modification.  The attached document shows the process to export an EnSight Case at the end of a steady state calculation.  <\/p>\n<p>Attachments:<br \/>\n1. <a href=https:\/\/ansys13.ansys.com\/KnowledgeArticles\/Phase-1\/2059179\/2059179.pdf>2059179.pdf<\/a><\/p>\n","protected":false},"template":"","class_list":["post-165874","topic","type-topic","status-publish","hentry","topic-tag-2019-r1","topic-tag-fluent","topic-tag-fluid-dynamics","topic-tag-general","topic-tag-general-fluent"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"When you want to execute text commands, macros, journals or Scheme scripts after a calculation is fin-ished, you can use the case modification feature that is described in the ANSYS Fluent 2019 R2 User\u2019s Guide, chapter 37.18. Automatic Initialization of the Solution and Case Modification. The attached document shows the process to export an EnSight\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"How to execute commands in ANSYS Fluent after a calculation has converged? | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"When you want to execute text commands, macros, journals or Scheme scripts after a calculation is fin-ished, you can use the case modification feature that is described in the ANSYS Fluent 2019 R2 User\u2019s Guide, chapter 37.18. Automatic Initialization of the Solution and Case Modification. The attached document shows the process to export an EnSight\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-03-17T13:10:29+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:26:54+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"How to execute commands in ANSYS Fluent after a calculation has converged? | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"When you want to execute text commands, macros, journals or Scheme scripts after a calculation is fin-ished, you can use the case modification feature that is described in the ANSYS Fluent 2019 R2 User\u2019s Guide, chapter 37.18. Automatic Initialization of the Solution and Case Modification. The attached document shows the process to export an EnSight\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"name\":\"fluent\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"position\":3,\"name\":\"fluent\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\\\/#listItem\",\"name\":\"How to execute commands in ANSYS Fluent after a calculation has converged?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\\\/#listItem\",\"position\":4,\"name\":\"How to execute commands in ANSYS Fluent after a calculation has converged?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"name\":\"fluent\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\\\/\",\"name\":\"How to execute commands in ANSYS Fluent after a calculation has converged? | Ansys Knowledge\",\"description\":\"When you want to execute text commands, macros, journals or Scheme scripts after a calculation is fin-ished, you can use the case modification feature that is described in the ANSYS Fluent 2019 R2 User\\u2019s Guide, chapter 37.18. Automatic Initialization of the Solution and Case Modification. The attached document shows the process to export an EnSight\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\\\/#breadcrumblist\"},\"datePublished\":\"2023-03-17T13:10:29+00:00\",\"dateModified\":\"2023-07-31T12:26:54+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"How to execute commands in ANSYS Fluent after a calculation has converged? | Ansys Knowledge","description":"When you want to execute text commands, macros, journals or Scheme scripts after a calculation is fin-ished, you can use the case modification feature that is described in the ANSYS Fluent 2019 R2 User\u2019s Guide, chapter 37.18. Automatic Initialization of the Solution and Case Modification. The attached document shows the process to export an EnSight","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","name":"fluent"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","position":3,"name":"fluent","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\/#listItem","name":"How to execute commands in ANSYS Fluent after a calculation has converged?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\/#listItem","position":4,"name":"How to execute commands in ANSYS Fluent after a calculation has converged?","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","name":"fluent"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\/","name":"How to execute commands in ANSYS Fluent after a calculation has converged? | Ansys Knowledge","description":"When you want to execute text commands, macros, journals or Scheme scripts after a calculation is fin-ished, you can use the case modification feature that is described in the ANSYS Fluent 2019 R2 User\u2019s Guide, chapter 37.18. Automatic Initialization of the Solution and Case Modification. The attached document shows the process to export an EnSight","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\/#breadcrumblist"},"datePublished":"2023-03-17T13:10:29+00:00","dateModified":"2023-07-31T12:26:54+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"How to execute commands in ANSYS Fluent after a calculation has converged? | Ansys Knowledge","og:description":"When you want to execute text commands, macros, journals or Scheme scripts after a calculation is fin-ished, you can use the case modification feature that is described in the ANSYS Fluent 2019 R2 User\u2019s Guide, chapter 37.18. Automatic Initialization of the Solution and Case Modification. The attached document shows the process to export an EnSight","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\/","article:published_time":"2023-03-17T13:10:29+00:00","article:modified_time":"2023-07-31T12:26:54+00:00","twitter:card":"summary_large_image","twitter:title":"How to execute commands in ANSYS Fluent after a calculation has converged? | Ansys Knowledge","twitter:description":"When you want to execute text commands, macros, journals or Scheme scripts after a calculation is fin-ished, you can use the case modification feature that is described in the ANSYS Fluent 2019 R2 User\u2019s Guide, chapter 37.18. Automatic Initialization of the Solution and Case Modification. The attached document shows the process to export an EnSight"},"aioseo_meta_data":{"post_id":"165874","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 22:34:04","updated":"2026-07-30 12:37:45","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/\" title=\"fluent\">fluent<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tHow to execute commands in ANSYS Fluent after a calculation has converged?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"fluent","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/"},{"label":"How to execute commands in ANSYS Fluent after a calculation has converged?","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-execute-commands-in-ansys-fluent-after-a-calculation-has-converged\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["3-15-2023  20:20:53"],"_bbp_forum_id":["27796"],"_bbp_author_ip":["23.56.168.180"],"_btv_view_count":["5003"],"siebel_km_number":["2059179"],"product_version":["2019 R1"],"km_published_date":["2019-05-20T12:46:14.000Z"],"family":["Fluid Dynamics"],"application_name":["FLUENT"]},"test":"solution"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/165874","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/165874\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=165874"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}