{"id":165016,"date":"2023-03-17T08:59:13","date_gmt":"2023-03-17T08:59:13","guid":{"rendered":"\/knowledge\/forums\/topic\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\/"},"modified":"2023-07-31T12:26:44","modified_gmt":"2023-07-31T12:26:44","slug":"how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\/","title":{"rendered":"How to display the particle variable &#8220;Time Integrated Wall Mass Flow Density&#8221; in moving mesh domains?"},"content":{"rendered":"<p>This variable by default is not available in moving mesh domains, as it will be incorrect for cases in which the mesh is deforming, i.e. the mesh moves relative to the associated wall. In such a case the integrated quantity would be moved to a different\/wrong location on the wall.  Thus, the integrated wall mass flow of particles can only be correct when the mesh is stationary on the wall. This is the case when i.e. the whole domain is moving and the mesh motion on the walls is defined as &#8220;Stationary&#8221;. For such cases the variable can be made available with the following expert parameter:   FLOW: Flow Analysis 1    EXPERT PARAMETERS:      pt mm time integrated bnd vertex arrays = t    END  END<\/p>\n","protected":false},"template":"","class_list":["post-165016","topic","type-topic","status-publish","hentry","topic-tag-2019-r1","topic-tag-cfx","topic-tag-fluid-dynamics","topic-tag-moving-deforming-mesh","topic-tag-mp-particle-tracking","topic-tag-multiphase","topic-tag-post-processing"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"This variable by default is not available in moving mesh domains, as it will be incorrect for cases in which the mesh is deforming, i.e. the mesh moves relative to the associated wall. In such a case the integrated quantity would be moved to a different\/wrong location on the wall. Thus, the integrated wall mass\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"How to display the particle variable \u201cTime Integrated Wall Mass Flow Density\u201d in moving mesh domains? | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"This variable by default is not available in moving mesh domains, as it will be incorrect for cases in which the mesh is deforming, i.e. the mesh moves relative to the associated wall. In such a case the integrated quantity would be moved to a different\/wrong location on the wall. Thus, the integrated wall mass\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-03-17T08:59:13+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:26:44+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"How to display the particle variable \u201cTime Integrated Wall Mass Flow Density\u201d in moving mesh domains? | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"This variable by default is not available in moving mesh domains, as it will be incorrect for cases in which the mesh is deforming, i.e. the mesh moves relative to the associated wall. In such a case the integrated quantity would be moved to a different\/wrong location on the wall. Thus, the integrated wall mass\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/cfx\\\/#listItem\",\"name\":\"cfx\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/cfx\\\/#listItem\",\"position\":3,\"name\":\"cfx\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/cfx\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\\\/#listItem\",\"name\":\"How to display the particle variable &#8220;Time Integrated Wall Mass Flow Density&#8221; in moving mesh domains?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\\\/#listItem\",\"position\":4,\"name\":\"How to display the particle variable &#8220;Time Integrated Wall Mass Flow Density&#8221; in moving mesh domains?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/cfx\\\/#listItem\",\"name\":\"cfx\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\\\/\",\"name\":\"How to display the particle variable \\u201cTime Integrated Wall Mass Flow Density\\u201d in moving mesh domains? | Ansys Knowledge\",\"description\":\"This variable by default is not available in moving mesh domains, as it will be incorrect for cases in which the mesh is deforming, i.e. the mesh moves relative to the associated wall. In such a case the integrated quantity would be moved to a different\\\/wrong location on the wall. Thus, the integrated wall mass\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\\\/#breadcrumblist\"},\"datePublished\":\"2023-03-17T08:59:13+00:00\",\"dateModified\":\"2023-07-31T12:26:44+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"How to display the particle variable \u201cTime Integrated Wall Mass Flow Density\u201d in moving mesh domains? | Ansys Knowledge","description":"This variable by default is not available in moving mesh domains, as it will be incorrect for cases in which the mesh is deforming, i.e. the mesh moves relative to the associated wall. In such a case the integrated quantity would be moved to a different\/wrong location on the wall. Thus, the integrated wall mass","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfx\/#listItem","name":"cfx"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfx\/#listItem","position":3,"name":"cfx","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfx\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\/#listItem","name":"How to display the particle variable &#8220;Time Integrated Wall Mass Flow Density&#8221; in moving mesh domains?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\/#listItem","position":4,"name":"How to display the particle variable &#8220;Time Integrated Wall Mass Flow Density&#8221; in moving mesh domains?","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfx\/#listItem","name":"cfx"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\/","name":"How to display the particle variable \u201cTime Integrated Wall Mass Flow Density\u201d in moving mesh domains? | Ansys Knowledge","description":"This variable by default is not available in moving mesh domains, as it will be incorrect for cases in which the mesh is deforming, i.e. the mesh moves relative to the associated wall. In such a case the integrated quantity would be moved to a different\/wrong location on the wall. Thus, the integrated wall mass","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\/#breadcrumblist"},"datePublished":"2023-03-17T08:59:13+00:00","dateModified":"2023-07-31T12:26:44+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"How to display the particle variable \u201cTime Integrated Wall Mass Flow Density\u201d in moving mesh domains? | Ansys Knowledge","og:description":"This variable by default is not available in moving mesh domains, as it will be incorrect for cases in which the mesh is deforming, i.e. the mesh moves relative to the associated wall. In such a case the integrated quantity would be moved to a different\/wrong location on the wall. Thus, the integrated wall mass","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\/","article:published_time":"2023-03-17T08:59:13+00:00","article:modified_time":"2023-07-31T12:26:44+00:00","twitter:card":"summary_large_image","twitter:title":"How to display the particle variable \u201cTime Integrated Wall Mass Flow Density\u201d in moving mesh domains? | Ansys Knowledge","twitter:description":"This variable by default is not available in moving mesh domains, as it will be incorrect for cases in which the mesh is deforming, i.e. the mesh moves relative to the associated wall. In such a case the integrated quantity would be moved to a different\/wrong location on the wall. Thus, the integrated wall mass"},"aioseo_meta_data":{"post_id":"165016","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 21:49:43","updated":"2026-07-29 15:35:11","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfx\/\" title=\"cfx\">cfx<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tHow to display the particle variable \u201cTime Integrated Wall Mass Flow Density\u201d in moving mesh domains?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"cfx","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfx\/"},{"label":"How to display the particle variable &#8220;Time Integrated Wall Mass Flow Density&#8221; in moving mesh domains?","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-display-the-particle-variable-time-integrated-wall-mass-flow-density-in-moving-mesh-domains\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["3-15-2023  20:20:37"],"_bbp_forum_id":["27809"],"_bbp_author_ip":["23.56.168.180"],"_btv_view_count":["507"],"siebel_km_number":["2059482"],"product_version":["2019 R1"],"km_published_date":["2019-06-21T00:00:00.000Z"],"family":["Fluid Dynamics"],"application_name":["CFX"],"_edit_lock":["1705045419:2"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/165016","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/165016\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=165016"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}