{"id":164822,"date":"2023-03-17T08:58:44","date_gmt":"2023-03-17T08:58:44","guid":{"rendered":"\/knowledge\/forums\/topic\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\/"},"modified":"2023-07-31T12:26:20","modified_gmt":"2023-07-31T12:26:20","slug":"what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\/","title":{"rendered":"What is the cause of ansys.exe error when trying to run ANSYS Classic in interactive mode?"},"content":{"rendered":"<p>In this case the customer had a program called CAX Interface (a customised interface for Mechanical Desktop 6 and SAP) that is using tcl as well, including an environment variable called tcl_library pointing to its installation. When this environment variable is deleted, then ANSYS Classic can be accessed from Interactive or Workbench.  The above variable is needed to run CAX. This variable can be active without affecting ANSYS. For this CAX needs to write their code independent of setting tcl_library.<\/p>\n","protected":false},"template":"","class_list":["post-164822","topic","type-topic","status-publish","hentry","topic-tag-4706","topic-tag-fluid-dynamics","topic-tag-general","topic-tag-icem-cfd"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"In this case the customer had a program called CAX Interface (a customised interface for Mechanical Desktop 6 and SAP) that is using tcl as well, including an environment variable called tcl_library pointing to its installation. When this environment variable is deleted, then ANSYS Classic can be accessed from Interactive or Workbench. The above variable\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"What is the cause of ansys.exe error when trying to run ANSYS Classic in interactive mode? | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"In this case the customer had a program called CAX Interface (a customised interface for Mechanical Desktop 6 and SAP) that is using tcl as well, including an environment variable called tcl_library pointing to its installation. When this environment variable is deleted, then ANSYS Classic can be accessed from Interactive or Workbench. The above variable\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-03-17T08:58:44+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:26:20+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"What is the cause of ansys.exe error when trying to run ANSYS Classic in interactive mode? | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"In this case the customer had a program called CAX Interface (a customised interface for Mechanical Desktop 6 and SAP) that is using tcl as well, including an environment variable called tcl_library pointing to its installation. When this environment variable is deleted, then ANSYS Classic can be accessed from Interactive or Workbench. The above variable\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/icem-cfd\\\/#listItem\",\"name\":\"icem-cfd\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/icem-cfd\\\/#listItem\",\"position\":3,\"name\":\"icem-cfd\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/icem-cfd\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\\\/#listItem\",\"name\":\"What is the cause of ansys.exe error when trying to run ANSYS Classic in interactive mode?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\\\/#listItem\",\"position\":4,\"name\":\"What is the cause of ansys.exe error when trying to run ANSYS Classic in interactive mode?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/icem-cfd\\\/#listItem\",\"name\":\"icem-cfd\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\\\/\",\"name\":\"What is the cause of ansys.exe error when trying to run ANSYS Classic in interactive mode? | Ansys Knowledge\",\"description\":\"In this case the customer had a program called CAX Interface (a customised interface for Mechanical Desktop 6 and SAP) that is using tcl as well, including an environment variable called tcl_library pointing to its installation. When this environment variable is deleted, then ANSYS Classic can be accessed from Interactive or Workbench. The above variable\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\\\/#breadcrumblist\"},\"datePublished\":\"2023-03-17T08:58:44+00:00\",\"dateModified\":\"2023-07-31T12:26:20+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"What is the cause of ansys.exe error when trying to run ANSYS Classic in interactive mode? | Ansys Knowledge","description":"In this case the customer had a program called CAX Interface (a customised interface for Mechanical Desktop 6 and SAP) that is using tcl as well, including an environment variable called tcl_library pointing to its installation. When this environment variable is deleted, then ANSYS Classic can be accessed from Interactive or Workbench. The above variable","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/icem-cfd\/#listItem","name":"icem-cfd"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/icem-cfd\/#listItem","position":3,"name":"icem-cfd","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/icem-cfd\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\/#listItem","name":"What is the cause of ansys.exe error when trying to run ANSYS Classic in interactive mode?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\/#listItem","position":4,"name":"What is the cause of ansys.exe error when trying to run ANSYS Classic in interactive mode?","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/icem-cfd\/#listItem","name":"icem-cfd"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\/","name":"What is the cause of ansys.exe error when trying to run ANSYS Classic in interactive mode? | Ansys Knowledge","description":"In this case the customer had a program called CAX Interface (a customised interface for Mechanical Desktop 6 and SAP) that is using tcl as well, including an environment variable called tcl_library pointing to its installation. When this environment variable is deleted, then ANSYS Classic can be accessed from Interactive or Workbench. The above variable","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\/#breadcrumblist"},"datePublished":"2023-03-17T08:58:44+00:00","dateModified":"2023-07-31T12:26:20+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"What is the cause of ansys.exe error when trying to run ANSYS Classic in interactive mode? | Ansys Knowledge","og:description":"In this case the customer had a program called CAX Interface (a customised interface for Mechanical Desktop 6 and SAP) that is using tcl as well, including an environment variable called tcl_library pointing to its installation. When this environment variable is deleted, then ANSYS Classic can be accessed from Interactive or Workbench. The above variable","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\/","article:published_time":"2023-03-17T08:58:44+00:00","article:modified_time":"2023-07-31T12:26:20+00:00","twitter:card":"summary_large_image","twitter:title":"What is the cause of ansys.exe error when trying to run ANSYS Classic in interactive mode? | Ansys Knowledge","twitter:description":"In this case the customer had a program called CAX Interface (a customised interface for Mechanical Desktop 6 and SAP) that is using tcl as well, including an environment variable called tcl_library pointing to its installation. When this environment variable is deleted, then ANSYS Classic can be accessed from Interactive or Workbench. The above variable"},"aioseo_meta_data":{"post_id":"164822","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 21:39:53","updated":"2026-07-29 14:50:41","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/icem-cfd\/\" title=\"icem-cfd\">icem-cfd<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tWhat is the cause of ansys.exe error when trying to run ANSYS Classic in interactive mode?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"icem-cfd","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/icem-cfd\/"},{"label":"What is the cause of ansys.exe error when trying to run ANSYS Classic in interactive mode?","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-is-the-cause-of-ansys-exe-error-when-trying-to-run-ansys-classic-in-interactive-mode\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["3-15-2023  20:20:26"],"_bbp_forum_id":["27796"],"_bbp_author_ip":["23.56.168.180"],"_btv_view_count":["792"],"siebel_km_number":["239533"],"product_version":["7"],"km_published_date":["2003-03-13T00:00:00.000Z"],"family":["Fluid Dynamics"],"application_name":["ICEM CFD"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/164822","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/164822\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=164822"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}