{"id":164797,"date":"2023-03-17T08:58:41","date_gmt":"2023-03-17T08:58:41","guid":{"rendered":"\/knowledge\/forums\/topic\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\/"},"modified":"2023-08-25T09:03:50","modified_gmt":"2023-08-25T09:03:50","slug":"how-do-i-configure-the-nx5-direct-interface-for-icem-cfd","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\/","title":{"rendered":"How do I configure the NX5 direct Interface for ICEM CFD?"},"content":{"rendered":"<p>The ICEM CFD direct interfaces are legacy translators and it is preferable to use the Workbench readers (&#8220;File&gt;Workbench Readers&#8221;). But if you still choose to use these older readers, then the following information is useful: The ICEM CFD NX4 reader was supported for Linux and Windows. Development of the NX5 reader was skipped, and the NX6 reader was only supported on Windows. The NX4 or NX6 reader can be used for NX5 by doing the following: The folder of the direct Interface is in the subfolder of ICEM: ..v110icemcfdwin{64_amd}difuglibug e.g. C:Program FilesANSYS Incv110icemcfdwindifuglibug e.g. ug22_vendor_dir (NX4) make a copy of this folder and rename it to ug23_vendor_dir (NX5) Or copy the ug24_vendor_dir to ug23_vendor_dir to use the NX6 interface for NX5. To configure the direct interface following variables have to be set: ICEM_ACN= Installation folder up to &#8220;win&#8221; e.g. C:Program FilesANSYS Incv110icemcfdwin{64_amd} UGII_VENDOR_DIR=..v110icemcfdwin{64_amd}difuglibugug23_vendor.dir e.g. C:Program FilesANSYS Incv110icemcfdwindifuglibugug23_vendor_dir&#8221;,Fluid Dynamics<\/p>\n","protected":false},"template":"","class_list":["post-164797","topic","type-topic","status-publish","hentry","topic-tag-icem-cfd"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"The ICEM CFD direct interfaces are legacy translators and it is preferable to use the Workbench readers (&quot;File&gt;Workbench Readers&quot;). But if you still choose to use these older readers, then the following information is useful: The ICEM CFD NX4 reader was supported for Linux and Windows. Development of the NX5 reader was skipped, and the\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"How do I configure the NX5 direct Interface for ICEM CFD? | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"The ICEM CFD direct interfaces are legacy translators and it is preferable to use the Workbench readers (&quot;File&gt;Workbench Readers&quot;). But if you still choose to use these older readers, then the following information is useful: The ICEM CFD NX4 reader was supported for Linux and Windows. Development of the NX5 reader was skipped, and the\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-03-17T08:58:41+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-08-25T09:03:50+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"How do I configure the NX5 direct Interface for ICEM CFD? | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"The ICEM CFD direct interfaces are legacy translators and it is preferable to use the Workbench readers (&quot;File&gt;Workbench Readers&quot;). But if you still choose to use these older readers, then the following information is useful: The ICEM CFD NX4 reader was supported for Linux and Windows. Development of the NX5 reader was skipped, and the\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/icem-cfd\\\/#listItem\",\"name\":\"icem-cfd\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/icem-cfd\\\/#listItem\",\"position\":3,\"name\":\"icem-cfd\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/icem-cfd\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\\\/#listItem\",\"name\":\"How do I configure the NX5 direct Interface for ICEM CFD?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\\\/#listItem\",\"position\":4,\"name\":\"How do I configure the NX5 direct Interface for ICEM CFD?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/icem-cfd\\\/#listItem\",\"name\":\"icem-cfd\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\\\/\",\"name\":\"How do I configure the NX5 direct Interface for ICEM CFD? | Ansys Knowledge\",\"description\":\"The ICEM CFD direct interfaces are legacy translators and it is preferable to use the Workbench readers (\\\"File>Workbench Readers\\\"). But if you still choose to use these older readers, then the following information is useful: The ICEM CFD NX4 reader was supported for Linux and Windows. Development of the NX5 reader was skipped, and the\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\\\/#breadcrumblist\"},\"datePublished\":\"2023-03-17T08:58:41+00:00\",\"dateModified\":\"2023-08-25T09:03:50+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"How do I configure the NX5 direct Interface for ICEM CFD? | Ansys Knowledge","description":"The ICEM CFD direct interfaces are legacy translators and it is preferable to use the Workbench readers (\"File>Workbench Readers\"). But if you still choose to use these older readers, then the following information is useful: The ICEM CFD NX4 reader was supported for Linux and Windows. Development of the NX5 reader was skipped, and the","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/icem-cfd\/#listItem","name":"icem-cfd"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/icem-cfd\/#listItem","position":3,"name":"icem-cfd","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/icem-cfd\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\/#listItem","name":"How do I configure the NX5 direct Interface for ICEM CFD?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\/#listItem","position":4,"name":"How do I configure the NX5 direct Interface for ICEM CFD?","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/icem-cfd\/#listItem","name":"icem-cfd"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\/","name":"How do I configure the NX5 direct Interface for ICEM CFD? | Ansys Knowledge","description":"The ICEM CFD direct interfaces are legacy translators and it is preferable to use the Workbench readers (\"File>Workbench Readers\"). But if you still choose to use these older readers, then the following information is useful: The ICEM CFD NX4 reader was supported for Linux and Windows. Development of the NX5 reader was skipped, and the","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\/#breadcrumblist"},"datePublished":"2023-03-17T08:58:41+00:00","dateModified":"2023-08-25T09:03:50+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"How do I configure the NX5 direct Interface for ICEM CFD? | Ansys Knowledge","og:description":"The ICEM CFD direct interfaces are legacy translators and it is preferable to use the Workbench readers (&quot;File&gt;Workbench Readers&quot;). But if you still choose to use these older readers, then the following information is useful: The ICEM CFD NX4 reader was supported for Linux and Windows. Development of the NX5 reader was skipped, and the","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\/","article:published_time":"2023-03-17T08:58:41+00:00","article:modified_time":"2023-08-25T09:03:50+00:00","twitter:card":"summary_large_image","twitter:title":"How do I configure the NX5 direct Interface for ICEM CFD? | Ansys Knowledge","twitter:description":"The ICEM CFD direct interfaces are legacy translators and it is preferable to use the Workbench readers (&quot;File&gt;Workbench Readers&quot;). But if you still choose to use these older readers, then the following information is useful: The ICEM CFD NX4 reader was supported for Linux and Windows. Development of the NX5 reader was skipped, and the"},"aioseo_meta_data":{"post_id":"164797","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 21:38:15","updated":"2026-07-29 14:48:07","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/icem-cfd\/\" title=\"icem-cfd\">icem-cfd<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tHow do I configure the NX5 direct Interface for ICEM CFD?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"icem-cfd","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/icem-cfd\/"},{"label":"How do I configure the NX5 direct Interface for ICEM CFD?","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-do-i-configure-the-nx5-direct-interface-for-icem-cfd\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"siebel_km_number":["closed"],"_bbp_last_active_time":["76744"],"_bbp_forum_id":["27796"],"_bbp_author_ip":["general\""],"_btv_view_count":["358"],"_edit_lock":["1692954105:76714"],"_edit_last":["76714"],"_bbp_topic_id":["164797"],"_yoast_wpseo_content_score":["60"],"_yoast_wpseo_estimated-reading-time-minutes":["1"],"_yoast_wpseo_wordproof_timestamp":[""],"application_name":[""],"_application_name":["field_64a80903c8e15"],"family":[""],"_family":["field_64a809229a857"],"_siebel_km_number":["field_63ecbffce60db"],"salesforce_km_number":[""],"_salesforce_km_number":["field_63ecc018e60dc"],"km_published_date":[""],"_km_published_date":["field_64c77704499dd"],"product_version":[""],"_product_version":["field_64c776cb4fd2e"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/164797","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/164797\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=164797"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}