{"id":164553,"date":"2023-03-17T08:58:03","date_gmt":"2023-03-17T08:58:03","guid":{"rendered":"\/knowledge\/forums\/topic\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\/"},"modified":"2023-07-31T12:25:48","modified_gmt":"2023-07-31T12:25:48","slug":"what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\/","title":{"rendered":"What about the Warning &#8220;Topology simplification is activated with the following restrictions&#8221;?"},"content":{"rendered":"<p>This following Warning may appears in CFX-Solver from v18.1: &#8221; Topology simplification is activated with the following restrictions: &#8211; Mesh regions referenced only within User Fortran and NOT in the command file will cause the solver to stop. &#8211; The solver will stop during any &#8220;Edit Run in Progress&#8221; step if new 2D regions are referenced. &#8221;  This warns that only the mesh regions defined in the Domains and Boundary Conditions in CFX-Pre will be saved in the .def file for the calculation. So no additional Region can be used in user Fortran or during Edit Run In Progress option during the calculation. So in the majority of the cases, this warning won&#8217;t affect the calculation.<\/p>\n","protected":false},"template":"","class_list":["post-164553","topic","type-topic","status-publish","hentry","topic-tag-18-1","topic-tag-cfx","topic-tag-fluid-dynamics","topic-tag-general","topic-tag-general-cfx"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"This following Warning may appears in CFX-Solver from v18.1: &quot; Topology simplification is activated with the following restrictions: - Mesh regions referenced only within User Fortran and NOT in the command file will cause the solver to stop. - The solver will stop during any &quot;Edit Run in Progress&quot; step if new 2D regions are\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"What about the Warning \u201cTopology simplification is activated with the following restrictions\u201d? | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"This following Warning may appears in CFX-Solver from v18.1: &quot; Topology simplification is activated with the following restrictions: - Mesh regions referenced only within User Fortran and NOT in the command file will cause the solver to stop. - The solver will stop during any &quot;Edit Run in Progress&quot; step if new 2D regions are\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-03-17T08:58:03+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:25:48+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"What about the Warning \u201cTopology simplification is activated with the following restrictions\u201d? | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"This following Warning may appears in CFX-Solver from v18.1: &quot; Topology simplification is activated with the following restrictions: - Mesh regions referenced only within User Fortran and NOT in the command file will cause the solver to stop. - The solver will stop during any &quot;Edit Run in Progress&quot; step if new 2D regions are\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/cfx\\\/#listItem\",\"name\":\"cfx\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/cfx\\\/#listItem\",\"position\":3,\"name\":\"cfx\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/cfx\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\\\/#listItem\",\"name\":\"What about the Warning &#8220;Topology simplification is activated with the following restrictions&#8221;?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\\\/#listItem\",\"position\":4,\"name\":\"What about the Warning &#8220;Topology simplification is activated with the following restrictions&#8221;?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/cfx\\\/#listItem\",\"name\":\"cfx\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\\\/\",\"name\":\"What about the Warning \\u201cTopology simplification is activated with the following restrictions\\u201d? | Ansys Knowledge\",\"description\":\"This following Warning may appears in CFX-Solver from v18.1: \\\" Topology simplification is activated with the following restrictions: - Mesh regions referenced only within User Fortran and NOT in the command file will cause the solver to stop. - The solver will stop during any \\\"Edit Run in Progress\\\" step if new 2D regions are\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\\\/#breadcrumblist\"},\"datePublished\":\"2023-03-17T08:58:03+00:00\",\"dateModified\":\"2023-07-31T12:25:48+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"What about the Warning \u201cTopology simplification is activated with the following restrictions\u201d? | Ansys Knowledge","description":"This following Warning may appears in CFX-Solver from v18.1: \" Topology simplification is activated with the following restrictions: - Mesh regions referenced only within User Fortran and NOT in the command file will cause the solver to stop. - The solver will stop during any \"Edit Run in Progress\" step if new 2D regions are","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfx\/#listItem","name":"cfx"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfx\/#listItem","position":3,"name":"cfx","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfx\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\/#listItem","name":"What about the Warning &#8220;Topology simplification is activated with the following restrictions&#8221;?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\/#listItem","position":4,"name":"What about the Warning &#8220;Topology simplification is activated with the following restrictions&#8221;?","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfx\/#listItem","name":"cfx"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\/","name":"What about the Warning \u201cTopology simplification is activated with the following restrictions\u201d? | Ansys Knowledge","description":"This following Warning may appears in CFX-Solver from v18.1: \" Topology simplification is activated with the following restrictions: - Mesh regions referenced only within User Fortran and NOT in the command file will cause the solver to stop. - The solver will stop during any \"Edit Run in Progress\" step if new 2D regions are","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\/#breadcrumblist"},"datePublished":"2023-03-17T08:58:03+00:00","dateModified":"2023-07-31T12:25:48+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"What about the Warning \u201cTopology simplification is activated with the following restrictions\u201d? | Ansys Knowledge","og:description":"This following Warning may appears in CFX-Solver from v18.1: &quot; Topology simplification is activated with the following restrictions: - Mesh regions referenced only within User Fortran and NOT in the command file will cause the solver to stop. - The solver will stop during any &quot;Edit Run in Progress&quot; step if new 2D regions are","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\/","article:published_time":"2023-03-17T08:58:03+00:00","article:modified_time":"2023-07-31T12:25:48+00:00","twitter:card":"summary_large_image","twitter:title":"What about the Warning \u201cTopology simplification is activated with the following restrictions\u201d? | Ansys Knowledge","twitter:description":"This following Warning may appears in CFX-Solver from v18.1: &quot; Topology simplification is activated with the following restrictions: - Mesh regions referenced only within User Fortran and NOT in the command file will cause the solver to stop. - The solver will stop during any &quot;Edit Run in Progress&quot; step if new 2D regions are"},"aioseo_meta_data":{"post_id":"164553","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 21:25:53","updated":"2026-07-29 14:08:40","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfx\/\" title=\"cfx\">cfx<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tWhat about the Warning \u201cTopology simplification is activated with the following restrictions\u201d?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"cfx","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/cfx\/"},{"label":"What about the Warning &#8220;Topology simplification is activated with the following restrictions&#8221;?","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-about-the-warning-topology-simplification-is-activated-with-the-following-restrictions\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["3-15-2023  20:20:00"],"_bbp_forum_id":["27796"],"_bbp_author_ip":["23.56.168.180"],"_btv_view_count":["1985"],"siebel_km_number":["2058078"],"product_version":["18.1"],"km_published_date":["2019-01-25T00:00:00.000Z"],"family":["Fluid Dynamics"],"application_name":["CFX"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/164553","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/164553\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=164553"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}