{"id":163278,"date":"2023-01-31T09:25:57","date_gmt":"2023-01-31T09:25:57","guid":{"rendered":"\/knowledge\/forums\/topic\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\/"},"modified":"2023-07-31T12:38:15","modified_gmt":"2023-07-31T12:38:15","slug":"%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\/","title":{"rendered":"\u8a98\u96fb\u4f53\u8584\u819c\u3092\u30e1\u30c3\u30ad\u5c0e\u4f53\u3068\u5171\u306b Layered Impedance \u306b\u53d6\u308a\u8fbc\u3093\u3067\u8a2d\u5b9a\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3059\u304b\uff1f"},"content":{"rendered":"<p>\u4ed6\u306e\u5c0e\u4f53\u3068\u76f4\u63a5\u63a5\u89e6\u3057\u306a\u3044\u9650\u308a\u306f\u3001\u307b\u307c\u5927\u4e08\u592b\u3067\u3059\u3002 \u554f\u984c\u306b\u306a\u308b\u306e\u306f\u3001\u8a98\u96fb\u4f53\u8584\u819c\u306e\u539a\u3055\u3092 t \u5165\u5c04\u6ce2\u306e\u30dd\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\u30d9\u30af\u30c8\u30eb\u3068\u6cd5\u7dda\u306e\u306a\u3059\u89d2\uff08\u5165\u5c04\u89d2\uff09\u3092 \u03b8 \u3068\u3057\u305f\u6642\u306e t\/cos\u03b8 \u306e\u5024\u304c \u03bb\/4 \u306b\u8fd1\u3065\u3044\u305f\u6642\u3067\u3059\u3002\u5149\u8def\u5dee\u304c\u534a\u6ce2\u9577\u306b\u8fd1\u3065\u304f\u304b\u3089\u3067\u3059\u3002 \u3057\u304b\u3057\u539a\u3055 t \u304c\u5341\u5206\u306b\u8584\u3044\u306a\u3089\u3001\u03b8 \u304c 90deg \u306b\u76f8\u5f53\u306b\u8fd1\u3065\u3044\u305f\u5834\u5408\u306b\u9650\u3089\u308c\u307e\u3059\u3002\u305d\u306e\u5f71\u97ff\u306f\u307b\u307c\u7121\u8996\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3057\u3087\u3046\u3002<\/p>\n","protected":false},"template":"","class_list":["post-163278","topic","type-topic","status-publish","hentry","topic-tag-2022-r1","topic-tag-boundaries","topic-tag-hfss","topic-tag-impedance-layered-impedance"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"\u4ed6\u306e\u5c0e\u4f53\u3068\u76f4\u63a5\u63a5\u89e6\u3057\u306a\u3044\u9650\u308a\u306f\u3001\u307b\u307c\u5927\u4e08\u592b\u3067\u3059\u3002 \u554f\u984c\u306b\u306a\u308b\u306e\u306f\u3001\u8a98\u96fb\u4f53\u8584\u819c\u306e\u539a\u3055\u3092 t \u5165\u5c04\u6ce2\u306e\u30dd\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\u30d9\u30af\u30c8\u30eb\u3068\u6cd5\u7dda\u306e\u306a\u3059\u89d2\uff08\u5165\u5c04\u89d2\uff09\u3092 \u03b8 \u3068\u3057\u305f\u6642\u306e t\/cos\u03b8 \u306e\u5024\u304c \u03bb\/4 \u306b\u8fd1\u3065\u3044\u305f\u6642\u3067\u3059\u3002\u5149\u8def\u5dee\u304c\u534a\u6ce2\u9577\u306b\u8fd1\u3065\u304f\u304b\u3089\u3067\u3059\u3002 \u3057\u304b\u3057\u539a\u3055 t \u304c\u5341\u5206\u306b\u8584\u3044\u306a\u3089\u3001\u03b8 \u304c 90deg \u306b\u76f8\u5f53\u306b\u8fd1\u3065\u3044\u305f\u5834\u5408\u306b\u9650\u3089\u308c\u307e\u3059\u3002\u305d\u306e\u5f71\u97ff\u306f\u307b\u307c\u7121\u8996\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3057\u3087\u3046\u3002\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"\u8a98\u96fb\u4f53\u8584\u819c\u3092\u30e1\u30c3\u30ad\u5c0e\u4f53\u3068\u5171\u306b Layered Impedance \u306b\u53d6\u308a\u8fbc\u3093\u3067\u8a2d\u5b9a\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3059\u304b\uff1f | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"\u4ed6\u306e\u5c0e\u4f53\u3068\u76f4\u63a5\u63a5\u89e6\u3057\u306a\u3044\u9650\u308a\u306f\u3001\u307b\u307c\u5927\u4e08\u592b\u3067\u3059\u3002 \u554f\u984c\u306b\u306a\u308b\u306e\u306f\u3001\u8a98\u96fb\u4f53\u8584\u819c\u306e\u539a\u3055\u3092 t \u5165\u5c04\u6ce2\u306e\u30dd\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\u30d9\u30af\u30c8\u30eb\u3068\u6cd5\u7dda\u306e\u306a\u3059\u89d2\uff08\u5165\u5c04\u89d2\uff09\u3092 \u03b8 \u3068\u3057\u305f\u6642\u306e t\/cos\u03b8 \u306e\u5024\u304c \u03bb\/4 \u306b\u8fd1\u3065\u3044\u305f\u6642\u3067\u3059\u3002\u5149\u8def\u5dee\u304c\u534a\u6ce2\u9577\u306b\u8fd1\u3065\u304f\u304b\u3089\u3067\u3059\u3002 \u3057\u304b\u3057\u539a\u3055 t \u304c\u5341\u5206\u306b\u8584\u3044\u306a\u3089\u3001\u03b8 \u304c 90deg \u306b\u76f8\u5f53\u306b\u8fd1\u3065\u3044\u305f\u5834\u5408\u306b\u9650\u3089\u308c\u307e\u3059\u3002\u305d\u306e\u5f71\u97ff\u306f\u307b\u307c\u7121\u8996\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3057\u3087\u3046\u3002\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-01-31T09:25:57+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:38:15+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"\u8a98\u96fb\u4f53\u8584\u819c\u3092\u30e1\u30c3\u30ad\u5c0e\u4f53\u3068\u5171\u306b Layered Impedance \u306b\u53d6\u308a\u8fbc\u3093\u3067\u8a2d\u5b9a\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3059\u304b\uff1f | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"\u4ed6\u306e\u5c0e\u4f53\u3068\u76f4\u63a5\u63a5\u89e6\u3057\u306a\u3044\u9650\u308a\u306f\u3001\u307b\u307c\u5927\u4e08\u592b\u3067\u3059\u3002 \u554f\u984c\u306b\u306a\u308b\u306e\u306f\u3001\u8a98\u96fb\u4f53\u8584\u819c\u306e\u539a\u3055\u3092 t \u5165\u5c04\u6ce2\u306e\u30dd\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\u30d9\u30af\u30c8\u30eb\u3068\u6cd5\u7dda\u306e\u306a\u3059\u89d2\uff08\u5165\u5c04\u89d2\uff09\u3092 \u03b8 \u3068\u3057\u305f\u6642\u306e t\/cos\u03b8 \u306e\u5024\u304c \u03bb\/4 \u306b\u8fd1\u3065\u3044\u305f\u6642\u3067\u3059\u3002\u5149\u8def\u5dee\u304c\u534a\u6ce2\u9577\u306b\u8fd1\u3065\u304f\u304b\u3089\u3067\u3059\u3002 \u3057\u304b\u3057\u539a\u3055 t \u304c\u5341\u5206\u306b\u8584\u3044\u306a\u3089\u3001\u03b8 \u304c 90deg \u306b\u76f8\u5f53\u306b\u8fd1\u3065\u3044\u305f\u5834\u5408\u306b\u9650\u3089\u308c\u307e\u3059\u3002\u305d\u306e\u5f71\u97ff\u306f\u307b\u307c\u7121\u8996\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3057\u3087\u3046\u3002\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/hfss\\\/?template=japan#listItem\",\"name\":\"hfss\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/hfss\\\/?template=japan#listItem\",\"position\":3,\"name\":\"hfss\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/hfss\\\/?template=japan\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\\\/#listItem\",\"name\":\"\\u8a98\\u96fb\\u4f53\\u8584\\u819c\\u3092\\u30e1\\u30c3\\u30ad\\u5c0e\\u4f53\\u3068\\u5171\\u306b Layered Impedance \\u306b\\u53d6\\u308a\\u8fbc\\u3093\\u3067\\u8a2d\\u5b9a\\u3057\\u3066\\u3082\\u5927\\u4e08\\u592b\\u3067\\u3059\\u304b\\uff1f\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\\\/#listItem\",\"position\":4,\"name\":\"\\u8a98\\u96fb\\u4f53\\u8584\\u819c\\u3092\\u30e1\\u30c3\\u30ad\\u5c0e\\u4f53\\u3068\\u5171\\u306b Layered Impedance \\u306b\\u53d6\\u308a\\u8fbc\\u3093\\u3067\\u8a2d\\u5b9a\\u3057\\u3066\\u3082\\u5927\\u4e08\\u592b\\u3067\\u3059\\u304b\\uff1f\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/hfss\\\/?template=japan#listItem\",\"name\":\"hfss\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\\\/\",\"name\":\"\\u8a98\\u96fb\\u4f53\\u8584\\u819c\\u3092\\u30e1\\u30c3\\u30ad\\u5c0e\\u4f53\\u3068\\u5171\\u306b Layered Impedance \\u306b\\u53d6\\u308a\\u8fbc\\u3093\\u3067\\u8a2d\\u5b9a\\u3057\\u3066\\u3082\\u5927\\u4e08\\u592b\\u3067\\u3059\\u304b\\uff1f | Ansys Knowledge\",\"description\":\"\\u4ed6\\u306e\\u5c0e\\u4f53\\u3068\\u76f4\\u63a5\\u63a5\\u89e6\\u3057\\u306a\\u3044\\u9650\\u308a\\u306f\\u3001\\u307b\\u307c\\u5927\\u4e08\\u592b\\u3067\\u3059\\u3002 \\u554f\\u984c\\u306b\\u306a\\u308b\\u306e\\u306f\\u3001\\u8a98\\u96fb\\u4f53\\u8584\\u819c\\u306e\\u539a\\u3055\\u3092 t \\u5165\\u5c04\\u6ce2\\u306e\\u30dd\\u30a4\\u30f3\\u30c6\\u30a3\\u30f3\\u30b0\\u30d9\\u30af\\u30c8\\u30eb\\u3068\\u6cd5\\u7dda\\u306e\\u306a\\u3059\\u89d2\\uff08\\u5165\\u5c04\\u89d2\\uff09\\u3092 \\u03b8 \\u3068\\u3057\\u305f\\u6642\\u306e t\\\/cos\\u03b8 \\u306e\\u5024\\u304c \\u03bb\\\/4 \\u306b\\u8fd1\\u3065\\u3044\\u305f\\u6642\\u3067\\u3059\\u3002\\u5149\\u8def\\u5dee\\u304c\\u534a\\u6ce2\\u9577\\u306b\\u8fd1\\u3065\\u304f\\u304b\\u3089\\u3067\\u3059\\u3002 \\u3057\\u304b\\u3057\\u539a\\u3055 t \\u304c\\u5341\\u5206\\u306b\\u8584\\u3044\\u306a\\u3089\\u3001\\u03b8 \\u304c 90deg \\u306b\\u76f8\\u5f53\\u306b\\u8fd1\\u3065\\u3044\\u305f\\u5834\\u5408\\u306b\\u9650\\u3089\\u308c\\u307e\\u3059\\u3002\\u305d\\u306e\\u5f71\\u97ff\\u306f\\u307b\\u307c\\u7121\\u8996\\u3057\\u3066\\u3082\\u5927\\u4e08\\u592b\\u3067\\u3057\\u3087\\u3046\\u3002\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\\\/#breadcrumblist\"},\"datePublished\":\"2023-01-31T09:25:57+00:00\",\"dateModified\":\"2023-07-31T12:38:15+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"\u8a98\u96fb\u4f53\u8584\u819c\u3092\u30e1\u30c3\u30ad\u5c0e\u4f53\u3068\u5171\u306b Layered Impedance \u306b\u53d6\u308a\u8fbc\u3093\u3067\u8a2d\u5b9a\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3059\u304b\uff1f | Ansys Knowledge","description":"\u4ed6\u306e\u5c0e\u4f53\u3068\u76f4\u63a5\u63a5\u89e6\u3057\u306a\u3044\u9650\u308a\u306f\u3001\u307b\u307c\u5927\u4e08\u592b\u3067\u3059\u3002 \u554f\u984c\u306b\u306a\u308b\u306e\u306f\u3001\u8a98\u96fb\u4f53\u8584\u819c\u306e\u539a\u3055\u3092 t \u5165\u5c04\u6ce2\u306e\u30dd\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\u30d9\u30af\u30c8\u30eb\u3068\u6cd5\u7dda\u306e\u306a\u3059\u89d2\uff08\u5165\u5c04\u89d2\uff09\u3092 \u03b8 \u3068\u3057\u305f\u6642\u306e t\/cos\u03b8 \u306e\u5024\u304c \u03bb\/4 \u306b\u8fd1\u3065\u3044\u305f\u6642\u3067\u3059\u3002\u5149\u8def\u5dee\u304c\u534a\u6ce2\u9577\u306b\u8fd1\u3065\u304f\u304b\u3089\u3067\u3059\u3002 \u3057\u304b\u3057\u539a\u3055 t \u304c\u5341\u5206\u306b\u8584\u3044\u306a\u3089\u3001\u03b8 \u304c 90deg \u306b\u76f8\u5f53\u306b\u8fd1\u3065\u3044\u305f\u5834\u5408\u306b\u9650\u3089\u308c\u307e\u3059\u3002\u305d\u306e\u5f71\u97ff\u306f\u307b\u307c\u7121\u8996\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3057\u3087\u3046\u3002","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/hfss\/?template=japan#listItem","name":"hfss"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/hfss\/?template=japan#listItem","position":3,"name":"hfss","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/hfss\/?template=japan","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\/#listItem","name":"\u8a98\u96fb\u4f53\u8584\u819c\u3092\u30e1\u30c3\u30ad\u5c0e\u4f53\u3068\u5171\u306b Layered Impedance \u306b\u53d6\u308a\u8fbc\u3093\u3067\u8a2d\u5b9a\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3059\u304b\uff1f"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\/#listItem","position":4,"name":"\u8a98\u96fb\u4f53\u8584\u819c\u3092\u30e1\u30c3\u30ad\u5c0e\u4f53\u3068\u5171\u306b Layered Impedance \u306b\u53d6\u308a\u8fbc\u3093\u3067\u8a2d\u5b9a\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3059\u304b\uff1f","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/hfss\/?template=japan#listItem","name":"hfss"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\/","name":"\u8a98\u96fb\u4f53\u8584\u819c\u3092\u30e1\u30c3\u30ad\u5c0e\u4f53\u3068\u5171\u306b Layered Impedance \u306b\u53d6\u308a\u8fbc\u3093\u3067\u8a2d\u5b9a\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3059\u304b\uff1f | Ansys Knowledge","description":"\u4ed6\u306e\u5c0e\u4f53\u3068\u76f4\u63a5\u63a5\u89e6\u3057\u306a\u3044\u9650\u308a\u306f\u3001\u307b\u307c\u5927\u4e08\u592b\u3067\u3059\u3002 \u554f\u984c\u306b\u306a\u308b\u306e\u306f\u3001\u8a98\u96fb\u4f53\u8584\u819c\u306e\u539a\u3055\u3092 t \u5165\u5c04\u6ce2\u306e\u30dd\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\u30d9\u30af\u30c8\u30eb\u3068\u6cd5\u7dda\u306e\u306a\u3059\u89d2\uff08\u5165\u5c04\u89d2\uff09\u3092 \u03b8 \u3068\u3057\u305f\u6642\u306e t\/cos\u03b8 \u306e\u5024\u304c \u03bb\/4 \u306b\u8fd1\u3065\u3044\u305f\u6642\u3067\u3059\u3002\u5149\u8def\u5dee\u304c\u534a\u6ce2\u9577\u306b\u8fd1\u3065\u304f\u304b\u3089\u3067\u3059\u3002 \u3057\u304b\u3057\u539a\u3055 t \u304c\u5341\u5206\u306b\u8584\u3044\u306a\u3089\u3001\u03b8 \u304c 90deg \u306b\u76f8\u5f53\u306b\u8fd1\u3065\u3044\u305f\u5834\u5408\u306b\u9650\u3089\u308c\u307e\u3059\u3002\u305d\u306e\u5f71\u97ff\u306f\u307b\u307c\u7121\u8996\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3057\u3087\u3046\u3002","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\/#breadcrumblist"},"datePublished":"2023-01-31T09:25:57+00:00","dateModified":"2023-07-31T12:38:15+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"\u8a98\u96fb\u4f53\u8584\u819c\u3092\u30e1\u30c3\u30ad\u5c0e\u4f53\u3068\u5171\u306b Layered Impedance \u306b\u53d6\u308a\u8fbc\u3093\u3067\u8a2d\u5b9a\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3059\u304b\uff1f | Ansys Knowledge","og:description":"\u4ed6\u306e\u5c0e\u4f53\u3068\u76f4\u63a5\u63a5\u89e6\u3057\u306a\u3044\u9650\u308a\u306f\u3001\u307b\u307c\u5927\u4e08\u592b\u3067\u3059\u3002 \u554f\u984c\u306b\u306a\u308b\u306e\u306f\u3001\u8a98\u96fb\u4f53\u8584\u819c\u306e\u539a\u3055\u3092 t \u5165\u5c04\u6ce2\u306e\u30dd\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\u30d9\u30af\u30c8\u30eb\u3068\u6cd5\u7dda\u306e\u306a\u3059\u89d2\uff08\u5165\u5c04\u89d2\uff09\u3092 \u03b8 \u3068\u3057\u305f\u6642\u306e t\/cos\u03b8 \u306e\u5024\u304c \u03bb\/4 \u306b\u8fd1\u3065\u3044\u305f\u6642\u3067\u3059\u3002\u5149\u8def\u5dee\u304c\u534a\u6ce2\u9577\u306b\u8fd1\u3065\u304f\u304b\u3089\u3067\u3059\u3002 \u3057\u304b\u3057\u539a\u3055 t \u304c\u5341\u5206\u306b\u8584\u3044\u306a\u3089\u3001\u03b8 \u304c 90deg \u306b\u76f8\u5f53\u306b\u8fd1\u3065\u3044\u305f\u5834\u5408\u306b\u9650\u3089\u308c\u307e\u3059\u3002\u305d\u306e\u5f71\u97ff\u306f\u307b\u307c\u7121\u8996\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3057\u3087\u3046\u3002","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\/","article:published_time":"2023-01-31T09:25:57+00:00","article:modified_time":"2023-07-31T12:38:15+00:00","twitter:card":"summary_large_image","twitter:title":"\u8a98\u96fb\u4f53\u8584\u819c\u3092\u30e1\u30c3\u30ad\u5c0e\u4f53\u3068\u5171\u306b Layered Impedance \u306b\u53d6\u308a\u8fbc\u3093\u3067\u8a2d\u5b9a\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3059\u304b\uff1f | Ansys Knowledge","twitter:description":"\u4ed6\u306e\u5c0e\u4f53\u3068\u76f4\u63a5\u63a5\u89e6\u3057\u306a\u3044\u9650\u308a\u306f\u3001\u307b\u307c\u5927\u4e08\u592b\u3067\u3059\u3002 \u554f\u984c\u306b\u306a\u308b\u306e\u306f\u3001\u8a98\u96fb\u4f53\u8584\u819c\u306e\u539a\u3055\u3092 t \u5165\u5c04\u6ce2\u306e\u30dd\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\u30d9\u30af\u30c8\u30eb\u3068\u6cd5\u7dda\u306e\u306a\u3059\u89d2\uff08\u5165\u5c04\u89d2\uff09\u3092 \u03b8 \u3068\u3057\u305f\u6642\u306e t\/cos\u03b8 \u306e\u5024\u304c \u03bb\/4 \u306b\u8fd1\u3065\u3044\u305f\u6642\u3067\u3059\u3002\u5149\u8def\u5dee\u304c\u534a\u6ce2\u9577\u306b\u8fd1\u3065\u304f\u304b\u3089\u3067\u3059\u3002 \u3057\u304b\u3057\u539a\u3055 t \u304c\u5341\u5206\u306b\u8584\u3044\u306a\u3089\u3001\u03b8 \u304c 90deg \u306b\u76f8\u5f53\u306b\u8fd1\u3065\u3044\u305f\u5834\u5408\u306b\u9650\u3089\u308c\u307e\u3059\u3002\u305d\u306e\u5f71\u97ff\u306f\u307b\u307c\u7121\u8996\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3057\u3087\u3046\u3002"},"aioseo_meta_data":{"post_id":"163278","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 20:31:16","updated":"2026-07-29 09:15:20","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/hfss\/?template=japan\" title=\"hfss\">hfss<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t\u8a98\u96fb\u4f53\u8584\u819c\u3092\u30e1\u30c3\u30ad\u5c0e\u4f53\u3068\u5171\u306b Layered Impedance \u306b\u53d6\u308a\u8fbc\u3093\u3067\u8a2d\u5b9a\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3059\u304b\uff1f\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"hfss","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/hfss\/?template=japan"},{"label":"\u8a98\u96fb\u4f53\u8584\u819c\u3092\u30e1\u30c3\u30ad\u5c0e\u4f53\u3068\u5171\u306b Layered Impedance \u306b\u53d6\u308a\u8fbc\u3093\u3067\u8a2d\u5b9a\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3059\u304b\uff1f","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/%e8%aa%98%e9%9b%bb%e4%bd%93%e8%96%84%e8%86%9c%e3%82%92%e3%83%a1%e3%83%83%e3%82%ad%e5%b0%8e%e4%bd%93%e3%81%a8%e5%85%b1%e3%81%ab-layered-impedance-%e3%81%ab%e5%8f%96%e3%82%8a%e8%be%bc%e3%82%93%e3%81%a7\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["1-31-2023  20:20:51"],"_bbp_forum_id":["162358"],"_bbp_author_ip":["209.182.204.162"],"_btv_view_count":["373"],"siebel_km_number":["2067844"],"product_version":["2022 R1"],"km_published_date":["5\/25\/2022 6:30"],"family":["Electromagnetics & Electronics"],"application_name":["HFSS"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/163278","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/163278\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=163278"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}