{"id":161811,"date":"2023-01-25T07:17:01","date_gmt":"2023-01-25T07:17:01","guid":{"rendered":"\/knowledge\/forums\/topic\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\/"},"modified":"2023-07-31T12:36:43","modified_gmt":"2023-07-31T12:36:43","slug":"the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\/","title":{"rendered":"The heat of vaporization is usually given in J\/kg. The other SI derived unit is in Joule per mole or Joule per kilomol ( kmol or kgmol) which is used by ANSYS Fluent. How can I convert my input so that it might be used in ANSYS Fluent?"},"content":{"rendered":"<p>In ANSYS Fluent the dimension of the molecular weight is expressed in kg\/kmol (kg\/kgmol = kg per 1000 moles).   So to get the correct input of heat of vaporization or in general the standard state enthalpy of particular fluid at a reference temperature for Fluent the conversion below is required:  standard state enthalpy in [J\/kg]* Molar Mass [kg\/kgmol] = Latent Heat in [J\/kgmol ]  Keywords: Latent Heat, kg\/kmol, molecular weight<\/p>\n","protected":false},"template":"","class_list":["post-161811","topic","type-topic","status-publish","hentry","topic-tag-2019-r1","topic-tag-fluent","topic-tag-fluid-dynamics","topic-tag-mp-eulerian-mp-flow","topic-tag-multiphase","topic-tag-phase-change"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"In ANSYS Fluent the dimension of the molecular weight is expressed in kg\/kmol (kg\/kgmol = kg per 1000 moles). So to get the correct input of heat of vaporization or in general the standard state enthalpy of particular fluid at a reference temperature for Fluent the conversion below is required: standard state enthalpy in [J\/kg]*\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"The heat of vaporization is usually given in J\/kg. The other SI derived unit is in Joule per mole or Joule per kilomol ( kmol or kgmol) which is used by ANSYS Fluent. How can I convert my input so that it might be used in ANSYS Fluent? | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"In ANSYS Fluent the dimension of the molecular weight is expressed in kg\/kmol (kg\/kgmol = kg per 1000 moles). So to get the correct input of heat of vaporization or in general the standard state enthalpy of particular fluid at a reference temperature for Fluent the conversion below is required: standard state enthalpy in [J\/kg]*\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-01-25T07:17:01+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:36:43+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"The heat of vaporization is usually given in J\/kg. The other SI derived unit is in Joule per mole or Joule per kilomol ( kmol or kgmol) which is used by ANSYS Fluent. How can I convert my input so that it might be used in ANSYS Fluent? | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"In ANSYS Fluent the dimension of the molecular weight is expressed in kg\/kmol (kg\/kgmol = kg per 1000 moles). So to get the correct input of heat of vaporization or in general the standard state enthalpy of particular fluid at a reference temperature for Fluent the conversion below is required: standard state enthalpy in [J\/kg]*\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"name\":\"fluent\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"position\":3,\"name\":\"fluent\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\\\/#listItem\",\"name\":\"The heat of vaporization is usually given in J\\\/kg. The other SI derived unit is in Joule per mole or Joule per kilomol ( kmol or kgmol) which is used by ANSYS Fluent. How can I convert my input so that it might be used in ANSYS Fluent?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\\\/#listItem\",\"position\":4,\"name\":\"The heat of vaporization is usually given in J\\\/kg. The other SI derived unit is in Joule per mole or Joule per kilomol ( kmol or kgmol) which is used by ANSYS Fluent. How can I convert my input so that it might be used in ANSYS Fluent?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"name\":\"fluent\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\\\/\",\"name\":\"The heat of vaporization is usually given in J\\\/kg. The other SI derived unit is in Joule per mole or Joule per kilomol ( kmol or kgmol) which is used by ANSYS Fluent. How can I convert my input so that it might be used in ANSYS Fluent? | Ansys Knowledge\",\"description\":\"In ANSYS Fluent the dimension of the molecular weight is expressed in kg\\\/kmol (kg\\\/kgmol = kg per 1000 moles). So to get the correct input of heat of vaporization or in general the standard state enthalpy of particular fluid at a reference temperature for Fluent the conversion below is required: standard state enthalpy in [J\\\/kg]*\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\\\/#breadcrumblist\"},\"datePublished\":\"2023-01-25T07:17:01+00:00\",\"dateModified\":\"2023-07-31T12:36:43+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"The heat of vaporization is usually given in J\/kg. The other SI derived unit is in Joule per mole or Joule per kilomol ( kmol or kgmol) which is used by ANSYS Fluent. How can I convert my input so that it might be used in ANSYS Fluent? | Ansys Knowledge","description":"In ANSYS Fluent the dimension of the molecular weight is expressed in kg\/kmol (kg\/kgmol = kg per 1000 moles). So to get the correct input of heat of vaporization or in general the standard state enthalpy of particular fluid at a reference temperature for Fluent the conversion below is required: standard state enthalpy in [J\/kg]*","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","name":"fluent"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","position":3,"name":"fluent","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\/#listItem","name":"The heat of vaporization is usually given in J\/kg. The other SI derived unit is in Joule per mole or Joule per kilomol ( kmol or kgmol) which is used by ANSYS Fluent. How can I convert my input so that it might be used in ANSYS Fluent?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\/#listItem","position":4,"name":"The heat of vaporization is usually given in J\/kg. The other SI derived unit is in Joule per mole or Joule per kilomol ( kmol or kgmol) which is used by ANSYS Fluent. How can I convert my input so that it might be used in ANSYS Fluent?","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","name":"fluent"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\/","name":"The heat of vaporization is usually given in J\/kg. The other SI derived unit is in Joule per mole or Joule per kilomol ( kmol or kgmol) which is used by ANSYS Fluent. How can I convert my input so that it might be used in ANSYS Fluent? | Ansys Knowledge","description":"In ANSYS Fluent the dimension of the molecular weight is expressed in kg\/kmol (kg\/kgmol = kg per 1000 moles). So to get the correct input of heat of vaporization or in general the standard state enthalpy of particular fluid at a reference temperature for Fluent the conversion below is required: standard state enthalpy in [J\/kg]*","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\/#breadcrumblist"},"datePublished":"2023-01-25T07:17:01+00:00","dateModified":"2023-07-31T12:36:43+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"The heat of vaporization is usually given in J\/kg. The other SI derived unit is in Joule per mole or Joule per kilomol ( kmol or kgmol) which is used by ANSYS Fluent. How can I convert my input so that it might be used in ANSYS Fluent? | Ansys Knowledge","og:description":"In ANSYS Fluent the dimension of the molecular weight is expressed in kg\/kmol (kg\/kgmol = kg per 1000 moles). So to get the correct input of heat of vaporization or in general the standard state enthalpy of particular fluid at a reference temperature for Fluent the conversion below is required: standard state enthalpy in [J\/kg]*","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\/","article:published_time":"2023-01-25T07:17:01+00:00","article:modified_time":"2023-07-31T12:36:43+00:00","twitter:card":"summary_large_image","twitter:title":"The heat of vaporization is usually given in J\/kg. The other SI derived unit is in Joule per mole or Joule per kilomol ( kmol or kgmol) which is used by ANSYS Fluent. How can I convert my input so that it might be used in ANSYS Fluent? | Ansys Knowledge","twitter:description":"In ANSYS Fluent the dimension of the molecular weight is expressed in kg\/kmol (kg\/kgmol = kg per 1000 moles). So to get the correct input of heat of vaporization or in general the standard state enthalpy of particular fluid at a reference temperature for Fluent the conversion below is required: standard state enthalpy in [J\/kg]*"},"aioseo_meta_data":{"post_id":"161811","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 19:25:12","updated":"2026-07-29 06:15:29","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/\" title=\"fluent\">fluent<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tThe heat of vaporization is usually given in J\/kg. The other SI derived unit is in Joule per mole or Joule per kilomol ( kmol or kgmol) which is used by ANSYS Fluent. How can I convert my input so that it might be used in ANSYS Fluent?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"fluent","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/"},{"label":"The heat of vaporization is usually given in J\/kg. The other SI derived unit is in Joule per mole or Joule per kilomol ( kmol or kgmol) which is used by ANSYS Fluent. How can I convert my input so that it might be used in ANSYS Fluent?","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/the-heat-of-vaporization-is-usually-given-in-j-kg-the-other-si-derived-unit-is-in-joule-per-mole-or-joule-per-kilomol-kmol-or-kgmol-which-is-used-by-ansys-fluent-how-can-i-convert-my-input-so-tha\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_forum_id":["27809"],"_bbp_author_ip":["23.56.168.180"],"_bbp_last_active_time":["1-24-2023  20:20:11"],"_btv_view_count":["1004"],"siebel_km_number":["2058257"],"product_version":["2019 R1"],"km_published_date":["2019-02-21T19:28:06.000Z"],"family":["Fluid Dynamics"],"application_name":["FLUENT"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/161811","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/161811\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=161811"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}