{"id":161788,"date":"2023-01-25T07:16:57","date_gmt":"2023-01-25T07:16:57","guid":{"rendered":"\/knowledge\/forums\/topic\/what-should-be-ambient-temp-type-in-imported-convection-during-1-way-transfer-from-fluent-to-mechanical\/"},"modified":"2023-07-31T12:35:54","modified_gmt":"2023-07-31T12:35:54","slug":"what-should-be-ambient-temp-type-in-imported-convection-during-1-way-transfer-from-fluent-to-mechanical","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/what-should-be-ambient-temp-type-in-imported-convection-during-1-way-transfer-from-fluent-to-mechanical\/","title":{"rendered":"What should be Ambient Temp Type  in Imported Convection during 1-way transfer from Fluent to Mechanical?"},"content":{"rendered":"<p>The convection coefficient uses &#8220;Wall Func. Heat Tran. Coeff&#8221; (from Fluent) or &#8220;Wall Heat Transfer Coefficient&#8221; (from CFD-Post). This is based on wall functions and the reference temperature used for this formulation is &#8220;Wall Adjacent Temperature&#8221; (CFD near-wall temperature).   When using Fluent, the convection coefficient will always be based on the wall function heat transfer coefficient so the ambient temp type should always be kept as &#8220;CFD near-wall Temperature&#8221;. This option is here because CFX users have the option to define the HTC based on a constant value, in which case, the &#8220;Ambient Temp Type&#8221; should be set to constant to match.<\/p>\n","protected":false},"template":"","class_list":["post-161788","topic","type-topic","status-publish","hentry","topic-tag-fluent","topic-tag-fluid-dynamics","topic-tag-heat-transfer-and-radiation","topic-tag-heat-transfer","topic-tag-other"],"aioseo_notices":[],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_forum_id":["27791"],"_bbp_author_ip":["23.56.168.180"],"_bbp_last_active_time":["1-24-2023  20:20:24"],"_btv_view_count":["747"],"siebel_km_number":["2045760"],"product_version":["Other"],"km_published_date":["2016-12-19T16:41:33.000Z"],"family":["Fluid Dynamics"],"application_name":["FLUENT"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/161788","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/161788\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=161788"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}