{"id":161770,"date":"2023-01-25T07:16:54","date_gmt":"2023-01-25T07:16:54","guid":{"rendered":"\/knowledge\/forums\/topic\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\/"},"modified":"2023-07-31T12:35:52","modified_gmt":"2023-07-31T12:35:52","slug":"cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\/","title":{"rendered":"CHT results in FLuent calculation show patchy temperatures at the Fluid\/solid interface.  What are some things that can be tried to address this?"},"content":{"rendered":"<p>One issue with CHT can be that the internally-calculated solid timescale is too large and causes divergence.  Switching to the pseudo-transient coupled solver will allow you to set a smaller time scale for the solid and will help to keep temperatures bounded.  Another remedy that may work for highly convoluted CHT surfaces is to set an alternate formulation for wall temperatures.  In the text interface go to:   solve\/set\/expert   then say yes to the question: use alternate formulation for wall temperatures? [no]<\/p>\n","protected":false},"template":"","class_list":["post-161770","topic","type-topic","status-publish","hentry","topic-tag-2019-r2","topic-tag-conjugate-heat-transfer","topic-tag-fluent","topic-tag-fluid-dynamics","topic-tag-heat-transfer-and-radiation","topic-tag-heat-transfer"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"One issue with CHT can be that the internally-calculated solid timescale is too large and causes divergence. Switching to the pseudo-transient coupled solver will allow you to set a smaller time scale for the solid and will help to keep temperatures bounded. Another remedy that may work for highly convoluted CHT surfaces is to set\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"CHT results in FLuent calculation show patchy temperatures at the Fluid\/solid interface. What are some things that can be tried to address this? | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"One issue with CHT can be that the internally-calculated solid timescale is too large and causes divergence. Switching to the pseudo-transient coupled solver will allow you to set a smaller time scale for the solid and will help to keep temperatures bounded. Another remedy that may work for highly convoluted CHT surfaces is to set\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-01-25T07:16:54+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:35:52+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"CHT results in FLuent calculation show patchy temperatures at the Fluid\/solid interface. What are some things that can be tried to address this? | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"One issue with CHT can be that the internally-calculated solid timescale is too large and causes divergence. Switching to the pseudo-transient coupled solver will allow you to set a smaller time scale for the solid and will help to keep temperatures bounded. Another remedy that may work for highly convoluted CHT surfaces is to set\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"name\":\"fluent\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"position\":3,\"name\":\"fluent\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\\\/#listItem\",\"name\":\"CHT results in FLuent calculation show patchy temperatures at the Fluid\\\/solid interface.  What are some things that can be tried to address this?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\\\/#listItem\",\"position\":4,\"name\":\"CHT results in FLuent calculation show patchy temperatures at the Fluid\\\/solid interface.  What are some things that can be tried to address this?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"name\":\"fluent\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\\\/\",\"name\":\"CHT results in FLuent calculation show patchy temperatures at the Fluid\\\/solid interface. What are some things that can be tried to address this? | Ansys Knowledge\",\"description\":\"One issue with CHT can be that the internally-calculated solid timescale is too large and causes divergence. Switching to the pseudo-transient coupled solver will allow you to set a smaller time scale for the solid and will help to keep temperatures bounded. Another remedy that may work for highly convoluted CHT surfaces is to set\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\\\/#breadcrumblist\"},\"datePublished\":\"2023-01-25T07:16:54+00:00\",\"dateModified\":\"2023-07-31T12:35:52+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"CHT results in FLuent calculation show patchy temperatures at the Fluid\/solid interface. What are some things that can be tried to address this? | Ansys Knowledge","description":"One issue with CHT can be that the internally-calculated solid timescale is too large and causes divergence. Switching to the pseudo-transient coupled solver will allow you to set a smaller time scale for the solid and will help to keep temperatures bounded. Another remedy that may work for highly convoluted CHT surfaces is to set","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","name":"fluent"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","position":3,"name":"fluent","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\/#listItem","name":"CHT results in FLuent calculation show patchy temperatures at the Fluid\/solid interface.  What are some things that can be tried to address this?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\/#listItem","position":4,"name":"CHT results in FLuent calculation show patchy temperatures at the Fluid\/solid interface.  What are some things that can be tried to address this?","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","name":"fluent"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\/","name":"CHT results in FLuent calculation show patchy temperatures at the Fluid\/solid interface. What are some things that can be tried to address this? | Ansys Knowledge","description":"One issue with CHT can be that the internally-calculated solid timescale is too large and causes divergence. Switching to the pseudo-transient coupled solver will allow you to set a smaller time scale for the solid and will help to keep temperatures bounded. Another remedy that may work for highly convoluted CHT surfaces is to set","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\/#breadcrumblist"},"datePublished":"2023-01-25T07:16:54+00:00","dateModified":"2023-07-31T12:35:52+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"CHT results in FLuent calculation show patchy temperatures at the Fluid\/solid interface. What are some things that can be tried to address this? | Ansys Knowledge","og:description":"One issue with CHT can be that the internally-calculated solid timescale is too large and causes divergence. Switching to the pseudo-transient coupled solver will allow you to set a smaller time scale for the solid and will help to keep temperatures bounded. Another remedy that may work for highly convoluted CHT surfaces is to set","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\/","article:published_time":"2023-01-25T07:16:54+00:00","article:modified_time":"2023-07-31T12:35:52+00:00","twitter:card":"summary_large_image","twitter:title":"CHT results in FLuent calculation show patchy temperatures at the Fluid\/solid interface. What are some things that can be tried to address this? | Ansys Knowledge","twitter:description":"One issue with CHT can be that the internally-calculated solid timescale is too large and causes divergence. Switching to the pseudo-transient coupled solver will allow you to set a smaller time scale for the solid and will help to keep temperatures bounded. Another remedy that may work for highly convoluted CHT surfaces is to set"},"aioseo_meta_data":{"post_id":"161770","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 19:23:00","updated":"2026-07-29 06:10:34","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/\" title=\"fluent\">fluent<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tCHT results in FLuent calculation show patchy temperatures at the Fluid\/solid interface.  What are some things that can be tried to address this?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"fluent","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/"},{"label":"CHT results in FLuent calculation show patchy temperatures at the Fluid\/solid interface.  What are some things that can be tried to address this?","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/cht-results-in-fluent-calculation-show-patchy-temperatures-at-the-fluid-solid-interface-what-are-some-things-that-can-be-tried-to-address-this\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_forum_id":["27791"],"_bbp_author_ip":["23.56.168.180"],"_bbp_last_active_time":["1-24-2023  20:20:06"],"_btv_view_count":["1248"],"siebel_km_number":["2060892"],"product_version":["2019 R2"],"km_published_date":["2019-09-23T21:20:36.000Z"],"family":["Fluid Dynamics"],"application_name":["FLUENT"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/161770","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/161770\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=161770"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}