{"id":161652,"date":"2023-01-25T07:16:34","date_gmt":"2023-01-25T07:16:34","guid":{"rendered":"\/knowledge\/forums\/topic\/how-does-soec-complete-an-analysis-in-the-sofc-module\/"},"modified":"2023-07-31T12:35:39","modified_gmt":"2023-07-31T12:35:39","slug":"how-does-soec-complete-an-analysis-in-the-sofc-module","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-does-soec-complete-an-analysis-in-the-sofc-module\/","title":{"rendered":"How does SOEC complete an analysis in the SOFC module?"},"content":{"rendered":"<p>It is possible for SOFC to complete a SOEC analysis using the module. SOEC stands for solid oxide electrolysis cells. The following reaction will occur:   2H2O-> 2H2 + O2  The calculation method is very similar to SOEC. The sign of the current value should be set to negative or set the cell voltage greater than the open circuit voltage. It is also set up in the same manner in both the SOFC and SOEC analysis. Also, please note:  1.Voltage-tap is the hydrogen side, current-tap is set to the oxygen side 2.Anode is the hydrogen side, cathode is set to the oxygen side<\/p>\n","protected":false},"template":"","class_list":["post-161652","topic","type-topic","status-publish","hentry","topic-tag-4431","topic-tag-fluent","topic-tag-fluid-dynamics","topic-tag-general","topic-tag-general-fluent"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"It is possible for SOFC to complete a SOEC analysis using the module. SOEC stands for solid oxide electrolysis cells. The following reaction will occur: 2H2O-&gt; 2H2 + O2 The calculation method is very similar to SOEC. The sign of the current value should be set to negative or set the cell voltage greater than\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-does-soec-complete-an-analysis-in-the-sofc-module\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"How does SOEC complete an analysis in the SOFC module? | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"It is possible for SOFC to complete a SOEC analysis using the module. SOEC stands for solid oxide electrolysis cells. The following reaction will occur: 2H2O-&gt; 2H2 + O2 The calculation method is very similar to SOEC. The sign of the current value should be set to negative or set the cell voltage greater than\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-does-soec-complete-an-analysis-in-the-sofc-module\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-01-25T07:16:34+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:35:39+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"How does SOEC complete an analysis in the SOFC module? | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"It is possible for SOFC to complete a SOEC analysis using the module. SOEC stands for solid oxide electrolysis cells. The following reaction will occur: 2H2O-&gt; 2H2 + O2 The calculation method is very similar to SOEC. The sign of the current value should be set to negative or set the cell voltage greater than\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-does-soec-complete-an-analysis-in-the-sofc-module\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"name\":\"fluent\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"position\":3,\"name\":\"fluent\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-does-soec-complete-an-analysis-in-the-sofc-module\\\/#listItem\",\"name\":\"How does SOEC complete an analysis in the SOFC module?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-does-soec-complete-an-analysis-in-the-sofc-module\\\/#listItem\",\"position\":4,\"name\":\"How does SOEC complete an analysis in the SOFC module?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"name\":\"fluent\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-does-soec-complete-an-analysis-in-the-sofc-module\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-does-soec-complete-an-analysis-in-the-sofc-module\\\/\",\"name\":\"How does SOEC complete an analysis in the SOFC module? | Ansys Knowledge\",\"description\":\"It is possible for SOFC to complete a SOEC analysis using the module. SOEC stands for solid oxide electrolysis cells. The following reaction will occur: 2H2O-> 2H2 + O2 The calculation method is very similar to SOEC. The sign of the current value should be set to negative or set the cell voltage greater than\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-does-soec-complete-an-analysis-in-the-sofc-module\\\/#breadcrumblist\"},\"datePublished\":\"2023-01-25T07:16:34+00:00\",\"dateModified\":\"2023-07-31T12:35:39+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"How does SOEC complete an analysis in the SOFC module? | Ansys Knowledge","description":"It is possible for SOFC to complete a SOEC analysis using the module. SOEC stands for solid oxide electrolysis cells. The following reaction will occur: 2H2O-> 2H2 + O2 The calculation method is very similar to SOEC. The sign of the current value should be set to negative or set the cell voltage greater than","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-does-soec-complete-an-analysis-in-the-sofc-module\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-does-soec-complete-an-analysis-in-the-sofc-module\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","name":"fluent"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","position":3,"name":"fluent","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-does-soec-complete-an-analysis-in-the-sofc-module\/#listItem","name":"How does SOEC complete an analysis in the SOFC module?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-does-soec-complete-an-analysis-in-the-sofc-module\/#listItem","position":4,"name":"How does SOEC complete an analysis in the SOFC module?","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","name":"fluent"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-does-soec-complete-an-analysis-in-the-sofc-module\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-does-soec-complete-an-analysis-in-the-sofc-module\/","name":"How does SOEC complete an analysis in the SOFC module? | Ansys Knowledge","description":"It is possible for SOFC to complete a SOEC analysis using the module. SOEC stands for solid oxide electrolysis cells. The following reaction will occur: 2H2O-> 2H2 + O2 The calculation method is very similar to SOEC. The sign of the current value should be set to negative or set the cell voltage greater than","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-does-soec-complete-an-analysis-in-the-sofc-module\/#breadcrumblist"},"datePublished":"2023-01-25T07:16:34+00:00","dateModified":"2023-07-31T12:35:39+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"How does SOEC complete an analysis in the SOFC module? | Ansys Knowledge","og:description":"It is possible for SOFC to complete a SOEC analysis using the module. SOEC stands for solid oxide electrolysis cells. The following reaction will occur: 2H2O-&gt; 2H2 + O2 The calculation method is very similar to SOEC. The sign of the current value should be set to negative or set the cell voltage greater than","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-does-soec-complete-an-analysis-in-the-sofc-module\/","article:published_time":"2023-01-25T07:16:34+00:00","article:modified_time":"2023-07-31T12:35:39+00:00","twitter:card":"summary_large_image","twitter:title":"How does SOEC complete an analysis in the SOFC module? | Ansys Knowledge","twitter:description":"It is possible for SOFC to complete a SOEC analysis using the module. SOEC stands for solid oxide electrolysis cells. The following reaction will occur: 2H2O-&gt; 2H2 + O2 The calculation method is very similar to SOEC. The sign of the current value should be set to negative or set the cell voltage greater than"},"aioseo_meta_data":{"post_id":"161652","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 19:17:22","updated":"2026-07-29 05:44:33","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/\" title=\"fluent\">fluent<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tHow does SOEC complete an analysis in the SOFC module?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"fluent","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/"},{"label":"How does SOEC complete an analysis in the SOFC module?","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-does-soec-complete-an-analysis-in-the-sofc-module\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_forum_id":["27796"],"_bbp_author_ip":["23.56.168.180"],"_bbp_last_active_time":["1-24-2023  20:20:06"],"_btv_view_count":["741"],"siebel_km_number":["2043668"],"product_version":["17"],"km_published_date":["2016-10-05T01:42:54.000Z"],"family":["Fluid Dynamics"],"application_name":["FLUENT"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/161652","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/161652\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=161652"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}