{"id":161651,"date":"2023-01-25T07:16:34","date_gmt":"2023-01-25T07:16:34","guid":{"rendered":"\/knowledge\/forums\/topic\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\/"},"modified":"2023-07-31T12:35:39","modified_gmt":"2023-07-31T12:35:39","slug":"we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\/","title":{"rendered":"We come across two terminologies to measure sound level in broadband based sound prediction model.  1)      Acoustic Power level 2)      Surface acoustic power level  What is the difference and how the values are calculated with Mathematical description"},"content":{"rendered":"<p>The basic difference between Acoustic Power Level and Surface Acoustic Power Level is the nature of source being quadrapole or dipole.  Acoustic Power Level (dB) is useful for estimating the local quadrapole contribution to the total acoustics.  W[dB] = 10 log10 [Integral(Acoustic Power*dV)\/10^-12]    Surface Acoustic Power (dB) is useful for estimating the local dipole contribution to the total acoustic power.   W[dB] = 10 log10[Integral(Surface Acoustic Power* dA)\/10^-12]<\/p>\n","protected":false},"template":"","class_list":["post-161651","topic","type-topic","status-publish","hentry","topic-tag-17-1","topic-tag-fluent","topic-tag-fluid-dynamics","topic-tag-general","topic-tag-general-fluent"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"The basic difference between Acoustic Power Level and Surface Acoustic Power Level is the nature of source being quadrapole or dipole. Acoustic Power Level (dB) is useful for estimating the local quadrapole contribution to the total acoustics. W[dB] = 10 log10 [Integral(Acoustic Power*dV)\/10^-12] Surface Acoustic Power (dB) is useful for estimating the local dipole contribution\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"We come across two terminologies to measure sound level in broadband based sound prediction model. 1) Acoustic Power level 2) Surface acoustic power level What is the difference and how the values are calculated with Mathematical description | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"The basic difference between Acoustic Power Level and Surface Acoustic Power Level is the nature of source being quadrapole or dipole. Acoustic Power Level (dB) is useful for estimating the local quadrapole contribution to the total acoustics. W[dB] = 10 log10 [Integral(Acoustic Power*dV)\/10^-12] Surface Acoustic Power (dB) is useful for estimating the local dipole contribution\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-01-25T07:16:34+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:35:39+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"We come across two terminologies to measure sound level in broadband based sound prediction model. 1) Acoustic Power level 2) Surface acoustic power level What is the difference and how the values are calculated with Mathematical description | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"The basic difference between Acoustic Power Level and Surface Acoustic Power Level is the nature of source being quadrapole or dipole. Acoustic Power Level (dB) is useful for estimating the local quadrapole contribution to the total acoustics. W[dB] = 10 log10 [Integral(Acoustic Power*dV)\/10^-12] Surface Acoustic Power (dB) is useful for estimating the local dipole contribution\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"name\":\"fluent\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"position\":3,\"name\":\"fluent\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\\\/#listItem\",\"name\":\"We come across two terminologies to measure sound level in broadband based sound prediction model.  1)      Acoustic Power level 2)      Surface acoustic power level  What is the difference and how the values are calculated with Mathematical description\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\\\/#listItem\",\"position\":4,\"name\":\"We come across two terminologies to measure sound level in broadband based sound prediction model.  1)      Acoustic Power level 2)      Surface acoustic power level  What is the difference and how the values are calculated with Mathematical description\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"name\":\"fluent\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\\\/\",\"name\":\"We come across two terminologies to measure sound level in broadband based sound prediction model. 1) Acoustic Power level 2) Surface acoustic power level What is the difference and how the values are calculated with Mathematical description | Ansys Knowledge\",\"description\":\"The basic difference between Acoustic Power Level and Surface Acoustic Power Level is the nature of source being quadrapole or dipole. Acoustic Power Level (dB) is useful for estimating the local quadrapole contribution to the total acoustics. W[dB] = 10 log10 [Integral(Acoustic Power*dV)\\\/10^-12] Surface Acoustic Power (dB) is useful for estimating the local dipole contribution\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\\\/#breadcrumblist\"},\"datePublished\":\"2023-01-25T07:16:34+00:00\",\"dateModified\":\"2023-07-31T12:35:39+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"We come across two terminologies to measure sound level in broadband based sound prediction model. 1) Acoustic Power level 2) Surface acoustic power level What is the difference and how the values are calculated with Mathematical description | Ansys Knowledge","description":"The basic difference between Acoustic Power Level and Surface Acoustic Power Level is the nature of source being quadrapole or dipole. Acoustic Power Level (dB) is useful for estimating the local quadrapole contribution to the total acoustics. W[dB] = 10 log10 [Integral(Acoustic Power*dV)\/10^-12] Surface Acoustic Power (dB) is useful for estimating the local dipole contribution","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","name":"fluent"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","position":3,"name":"fluent","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\/#listItem","name":"We come across two terminologies to measure sound level in broadband based sound prediction model.  1)      Acoustic Power level 2)      Surface acoustic power level  What is the difference and how the values are calculated with Mathematical description"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\/#listItem","position":4,"name":"We come across two terminologies to measure sound level in broadband based sound prediction model.  1)      Acoustic Power level 2)      Surface acoustic power level  What is the difference and how the values are calculated with Mathematical description","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","name":"fluent"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\/","name":"We come across two terminologies to measure sound level in broadband based sound prediction model. 1) Acoustic Power level 2) Surface acoustic power level What is the difference and how the values are calculated with Mathematical description | Ansys Knowledge","description":"The basic difference between Acoustic Power Level and Surface Acoustic Power Level is the nature of source being quadrapole or dipole. Acoustic Power Level (dB) is useful for estimating the local quadrapole contribution to the total acoustics. W[dB] = 10 log10 [Integral(Acoustic Power*dV)\/10^-12] Surface Acoustic Power (dB) is useful for estimating the local dipole contribution","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\/#breadcrumblist"},"datePublished":"2023-01-25T07:16:34+00:00","dateModified":"2023-07-31T12:35:39+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"We come across two terminologies to measure sound level in broadband based sound prediction model. 1) Acoustic Power level 2) Surface acoustic power level What is the difference and how the values are calculated with Mathematical description | Ansys Knowledge","og:description":"The basic difference between Acoustic Power Level and Surface Acoustic Power Level is the nature of source being quadrapole or dipole. Acoustic Power Level (dB) is useful for estimating the local quadrapole contribution to the total acoustics. W[dB] = 10 log10 [Integral(Acoustic Power*dV)\/10^-12] Surface Acoustic Power (dB) is useful for estimating the local dipole contribution","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\/","article:published_time":"2023-01-25T07:16:34+00:00","article:modified_time":"2023-07-31T12:35:39+00:00","twitter:card":"summary_large_image","twitter:title":"We come across two terminologies to measure sound level in broadband based sound prediction model. 1) Acoustic Power level 2) Surface acoustic power level What is the difference and how the values are calculated with Mathematical description | Ansys Knowledge","twitter:description":"The basic difference between Acoustic Power Level and Surface Acoustic Power Level is the nature of source being quadrapole or dipole. Acoustic Power Level (dB) is useful for estimating the local quadrapole contribution to the total acoustics. W[dB] = 10 log10 [Integral(Acoustic Power*dV)\/10^-12] Surface Acoustic Power (dB) is useful for estimating the local dipole contribution"},"aioseo_meta_data":{"post_id":"161651","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 19:17:22","updated":"2026-07-29 05:44:33","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/\" title=\"fluent\">fluent<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tWe come across two terminologies to measure sound level in broadband based sound prediction model.  1)      Acoustic Power level 2)      Surface acoustic power level  What is the difference and how the values are calculated with Mathematical description\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"fluent","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/"},{"label":"We come across two terminologies to measure sound level in broadband based sound prediction model.  1)      Acoustic Power level 2)      Surface acoustic power level  What is the difference and how the values are calculated with Mathematical description","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/we-come-across-two-terminologies-to-measure-sound-level-in-broadband-based-sound-prediction-model-1-acoustic-power-level-2-surface-acoustic-power-level-what-is-the-difference-and-how-th\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_forum_id":["27796"],"_bbp_author_ip":["23.56.168.180"],"_bbp_last_active_time":["1-24-2023  20:20:05"],"_btv_view_count":["927"],"siebel_km_number":["2044529"],"product_version":["17.1"],"km_published_date":["2016-11-02T18:02:12.000Z"],"family":["Fluid Dynamics"],"application_name":["FLUENT"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/161651","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/161651\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=161651"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}