{"id":161517,"date":"2023-01-25T07:16:12","date_gmt":"2023-01-25T07:16:12","guid":{"rendered":"\/knowledge\/forums\/topic\/how-to-use-the-aerodynamic-damping-capability-of-tbr-for-non-turbo-applications\/"},"modified":"2023-07-31T12:35:26","modified_gmt":"2023-07-31T12:35:26","slug":"how-to-use-the-aerodynamic-damping-capability-of-tbr-for-non-turbo-applications","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-use-the-aerodynamic-damping-capability-of-tbr-for-non-turbo-applications\/","title":{"rendered":"How to use the aerodynamic damping capability of TBR for non-turbo applications."},"content":{"rendered":"<p>For details on using the aerodynamic damping capability of TBR, please review the CFX flutter tutorial. Below are the steps relevant to using the capability for non-turbo cases: 1) Set Analysis Type = Transient Blade Row 2) In fluid domain, set Mesh Deformation Option = Regions of Motion Specified.  &#8220;Set Pass. in Component&#8221; = 1 and &#8220;Passages in 360&#8221; = 1 3) Set wall boundary condition Mesh Motion Option = Periodic Displacement. Input Periodic displacement settings 4) Define transient settings in Transient Blade Row Models 5) In Output Control > Monitors > create a new monitor for Aerodynamic Damping<\/p>\n","protected":false},"template":"","class_list":["post-161517","topic","type-topic","status-publish","hentry","topic-tag-19-1","topic-tag-fluent","topic-tag-fluid-dynamics","topic-tag-fsi","topic-tag-modeling-setup-advice"],"aioseo_notices":[],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_forum_id":["27796"],"_bbp_author_ip":["23.56.168.180"],"_bbp_last_active_time":["1-24-2023  20:20:06"],"_btv_view_count":["558"],"siebel_km_number":["2058758"],"product_version":["19.1"],"km_published_date":["2019-03-29T20:59:37.000Z"],"family":["Fluid Dynamics"],"application_name":["FLUENT"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/161517","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/161517\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=161517"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}