{"id":161494,"date":"2023-01-25T07:16:05","date_gmt":"2023-01-25T07:16:05","guid":{"rendered":"\/knowledge\/forums\/topic\/best-practices-for-defining-bois-in-spaceclaim-designmodeler-for-use-in-fluent-meshing-workflow\/"},"modified":"2023-07-31T12:35:24","modified_gmt":"2023-07-31T12:35:24","slug":"best-practices-for-defining-bois-in-spaceclaim-designmodeler-for-use-in-fluent-meshing-workflow","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/best-practices-for-defining-bois-in-spaceclaim-designmodeler-for-use-in-fluent-meshing-workflow\/","title":{"rendered":"Best practices for defining BOIs in SpaceClaim\/DesignModeler for use in Fluent Meshing Workflow"},"content":{"rendered":"<p>1. SCDM\/DM: A BOI body must not share topology with the model itself. Use a unique name for each BOI body.  2. SCDM\/DM: Create a named selection from faces of the BOI body (not from the body itself). Create different named selections for faces of different BOI bodies. 3. FM workflow: All imported BOI labels must be defined in a local sizing. Multiple BOI labels in one local sizing is ok.  SCDM &#8211; Space Claim Direct Modeler DM &#8211; Design Modeler FM &#8211; Fluent Meshing  Keywords &#8211; SCDM; BOI; Watertight; Fluent Meshing;<\/p>\n","protected":false},"template":"","class_list":["post-161494","topic","type-topic","status-publish","hentry","topic-tag-fluent-meshing-tgrid","topic-tag-fluid-dynamics","topic-tag-watertight","topic-tag-workflows"],"aioseo_notices":[],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_forum_id":["27796"],"_bbp_author_ip":["23.56.168.180"],"_bbp_last_active_time":["1-24-2023  20:20:19"],"_btv_view_count":["2305"],"siebel_km_number":["2060240"],"product_version":[""],"km_published_date":["2019-08-02T20:44:36.000Z"],"family":["Fluid Dynamics"],"application_name":["FLUENT Meshing\/Tgrid"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/161494","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/161494\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=161494"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}