{"id":161491,"date":"2023-01-25T07:16:05","date_gmt":"2023-01-25T07:16:05","guid":{"rendered":"\/knowledge\/forums\/topic\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\/"},"modified":"2023-07-31T12:35:23","modified_gmt":"2023-07-31T12:35:23","slug":"how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\/","title":{"rendered":"How to handle the Fluent solver message: Warning: Unrecognized grid section 11."},"content":{"rendered":"<p>When loading a mesh file (* .msh \/ *. Msh.gz) into Fluent, the following warning message may be displayed in the console window.  Warning: Unrecognized grid section 11. and Warning: Unrecognized grid section 2011.  This is displayed because the edge zone information that does not need to be read by the solver has been written to the mesh file. If no error is displayed after performing Mesh-Check, it can be ignored, so you can set the condition as it is and calculate.  * &#8220;Grid section 11&#8221; corresponds to the edge in the grid section of the mesh. * &#8220;Grid section 2011&#8221; indicates that it was saved in single precision binary format, with 20 added just before 11 above.  In particular, if you created a mesh with Fluent Meshing, it will often appear if you forget to run &#8220;Prepare for Solve&#8221;, so try running Prepare for Solve (RMB on Model in the Outline View) before saving the mesh fill.  Related manuals B.3.8. Edges https:\/\/ansyshelp.ansys.com\/account\/secured?returnurl=\/Views\/Secured\/corp\/v194\/flu_ug\/tgd_user_format_edges.html  B.2. Formatting Conventions in Binary Files and Formatted Files https:\/\/ansyshelp.ansys.com\/account\/secured?returnurl=\/Views\/Secured\/corp\/v194\/flu_ug\/tgd_user_format_convbinary.html<\/p>\n","protected":false},"template":"","class_list":["post-161491","topic","type-topic","status-publish","hentry","topic-tag-2019-r2","topic-tag-fluent","topic-tag-fluid-dynamics","topic-tag-general","topic-tag-general-fluent"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"When loading a mesh file (* .msh \/ *. Msh.gz) into Fluent, the following warning message may be displayed in the console window. Warning: Unrecognized grid section 11. and Warning: Unrecognized grid section 2011. This is displayed because the edge zone information that does not need to be read by the solver has been written\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"How to handle the Fluent solver message: Warning: Unrecognized grid section 11. | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"When loading a mesh file (* .msh \/ *. Msh.gz) into Fluent, the following warning message may be displayed in the console window. Warning: Unrecognized grid section 11. and Warning: Unrecognized grid section 2011. This is displayed because the edge zone information that does not need to be read by the solver has been written\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-01-25T07:16:05+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2023-07-31T12:35:23+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"How to handle the Fluent solver message: Warning: Unrecognized grid section 11. | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"When loading a mesh file (* .msh \/ *. Msh.gz) into Fluent, the following warning message may be displayed in the console window. Warning: Unrecognized grid section 11. and Warning: Unrecognized grid section 2011. This is displayed because the edge zone information that does not need to be read by the solver has been written\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"name\":\"fluent\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"position\":3,\"name\":\"fluent\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\\\/#listItem\",\"name\":\"How to handle the Fluent solver message: Warning: Unrecognized grid section 11.\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\\\/#listItem\",\"position\":4,\"name\":\"How to handle the Fluent solver message: Warning: Unrecognized grid section 11.\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/fluent\\\/#listItem\",\"name\":\"fluent\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\\\/\",\"name\":\"How to handle the Fluent solver message: Warning: Unrecognized grid section 11. | Ansys Knowledge\",\"description\":\"When loading a mesh file (* .msh \\\/ *. Msh.gz) into Fluent, the following warning message may be displayed in the console window. Warning: Unrecognized grid section 11. and Warning: Unrecognized grid section 2011. This is displayed because the edge zone information that does not need to be read by the solver has been written\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\\\/#breadcrumblist\"},\"datePublished\":\"2023-01-25T07:16:05+00:00\",\"dateModified\":\"2023-07-31T12:35:23+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"How to handle the Fluent solver message: Warning: Unrecognized grid section 11. | Ansys Knowledge","description":"When loading a mesh file (* .msh \/ *. Msh.gz) into Fluent, the following warning message may be displayed in the console window. Warning: Unrecognized grid section 11. and Warning: Unrecognized grid section 2011. This is displayed because the edge zone information that does not need to be read by the solver has been written","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","name":"fluent"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","position":3,"name":"fluent","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\/#listItem","name":"How to handle the Fluent solver message: Warning: Unrecognized grid section 11."},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\/#listItem","position":4,"name":"How to handle the Fluent solver message: Warning: Unrecognized grid section 11.","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/#listItem","name":"fluent"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\/","name":"How to handle the Fluent solver message: Warning: Unrecognized grid section 11. | Ansys Knowledge","description":"When loading a mesh file (* .msh \/ *. Msh.gz) into Fluent, the following warning message may be displayed in the console window. Warning: Unrecognized grid section 11. and Warning: Unrecognized grid section 2011. This is displayed because the edge zone information that does not need to be read by the solver has been written","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\/#breadcrumblist"},"datePublished":"2023-01-25T07:16:05+00:00","dateModified":"2023-07-31T12:35:23+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"How to handle the Fluent solver message: Warning: Unrecognized grid section 11. | Ansys Knowledge","og:description":"When loading a mesh file (* .msh \/ *. Msh.gz) into Fluent, the following warning message may be displayed in the console window. Warning: Unrecognized grid section 11. and Warning: Unrecognized grid section 2011. This is displayed because the edge zone information that does not need to be read by the solver has been written","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\/","article:published_time":"2023-01-25T07:16:05+00:00","article:modified_time":"2023-07-31T12:35:23+00:00","twitter:card":"summary_large_image","twitter:title":"How to handle the Fluent solver message: Warning: Unrecognized grid section 11. | Ansys Knowledge","twitter:description":"When loading a mesh file (* .msh \/ *. Msh.gz) into Fluent, the following warning message may be displayed in the console window. Warning: Unrecognized grid section 11. and Warning: Unrecognized grid section 2011. This is displayed because the edge zone information that does not need to be read by the solver has been written"},"aioseo_meta_data":{"post_id":"161491","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 19:09:05","updated":"2026-07-29 05:23:12","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/\" title=\"fluent\">fluent<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tHow to handle the Fluent solver message: Warning: Unrecognized grid section 11.\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"fluent","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/fluent\/"},{"label":"How to handle the Fluent solver message: Warning: Unrecognized grid section 11.","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-handle-the-fluent-solver-message-warning-unrecognized-grid-section-11\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_forum_id":["27796"],"_bbp_author_ip":["23.56.168.180"],"_bbp_last_active_time":["1-24-2023  20:20:16"],"_btv_view_count":["1219"],"siebel_km_number":["2061321"],"product_version":["2019 R2"],"km_published_date":["2019-11-05T15:07:42.000Z"],"family":["Fluid Dynamics"],"application_name":["FLUENT"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/161491","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/161491\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=161491"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}