{"id":157982,"date":"2022-06-06T09:58:16","date_gmt":"2022-06-06T09:58:16","guid":{"rendered":"\/knowledge\/forums\/topic\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\/"},"modified":"2022-06-06T09:58:16","modified_gmt":"2022-06-06T09:58:16","slug":"is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\/","title":{"rendered":"Is it possible to define multiple load (Heat generation rate) in table type array parameter using a *DO loop?"},"content":{"rendered":"<p>Yes.  The following APDL commands demonstrate how to define multiple loads using *do loop;<\/p>\n<p>Fini<br \/>\/clear<br \/>\/output,out,out<\/p>\n<p>*cfopen,load,txt<br \/>*Do,i,1,2<\/p>\n<p>*DIM,BF%i%LOAD,TABLE,3,1,1,time,<\/p>\n<p>BF%i%LOAD(1,0) = 0,0.5,1 <br \/>BF%i%LOAD(1,1) = %i%*10,%i%*20,%i%*30<\/p>\n<p>*vwrite,i,i<br \/>bfv,%i,hgen,%%BF%iLOAD%%<\/p>\n<p>*enddo<br \/>*cfclos<\/p>\n<p>!create Solid model and mesh it<br \/>\/prep7<\/p>\n<p>mp,kxx,1,50<br \/>mp,dens,1,7850<br \/>mp,c,1,450<\/p>\n<p>et,1,70<br \/>block,,10,,1,,1<br \/>block,10.1,20.1,,1,,1<br \/>esize,.3<br \/>vmesh,all<\/p>\n<p>\/inp,load,txt<\/p>\n<p>\/solu<br \/>ANTYPE,4<br \/>TRNOPT,FULL <br \/>LUMPM,0 <br \/>TIME,1<br \/>solve<br \/>\/post1<br \/>\/EFACET,1   <br \/>PLNSOL, TEMP,, 0<\/p>\n","protected":false},"template":"","class_list":["post-157982","topic","type-topic","status-publish","hentry","topic-tag-apdl","topic-tag-array","topic-tag-do-loop","topic-tag-multiple-load"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"Yes. The following APDL commands demonstrate how to define multiple loads using *do loop;Fini\/clear\/output,out,out*cfopen,load,txt*Do,i,1,2*DIM,BF%i%LOAD,TABLE,3,1,1,time,BF%i%LOAD(1,0) = 0,0.5,1 BF%i%LOAD(1,1) = %i%*10,%i%*20,%i%*30*vwrite,i,ibfv,%i,hgen,%%BF%iLOAD%%*enddo*cfclos!create Solid model and mesh it\/prep7mp,kxx,1,50mp,dens,1,7850mp,c,1,450et,1,70block,,10,,1,,1block,10.1,20.1,,1,,1esize,.3vmesh,all\/inp,load,txt\/soluANTYPE,4TRNOPT,FULL LUMPM,0 TIME,1solve\/post1\/EFACET,1 PLNSOL, TEMP,, 0\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Is it possible to define multiple load (Heat generation rate) in table type array parameter using a *DO loop? | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"Yes. The following APDL commands demonstrate how to define multiple loads using *do loop;Fini\/clear\/output,out,out*cfopen,load,txt*Do,i,1,2*DIM,BF%i%LOAD,TABLE,3,1,1,time,BF%i%LOAD(1,0) = 0,0.5,1 BF%i%LOAD(1,1) = %i%*10,%i%*20,%i%*30*vwrite,i,ibfv,%i,hgen,%%BF%iLOAD%%*enddo*cfclos!create Solid model and mesh it\/prep7mp,kxx,1,50mp,dens,1,7850mp,c,1,450et,1,70block,,10,,1,,1block,10.1,20.1,,1,,1esize,.3vmesh,all\/inp,load,txt\/soluANTYPE,4TRNOPT,FULL LUMPM,0 TIME,1solve\/post1\/EFACET,1 PLNSOL, TEMP,, 0\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2022-06-06T09:58:16+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2022-06-06T09:58:16+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Is it possible to define multiple load (Heat generation rate) in table type array parameter using a *DO loop? | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Yes. The following APDL commands demonstrate how to define multiple loads using *do loop;Fini\/clear\/output,out,out*cfopen,load,txt*Do,i,1,2*DIM,BF%i%LOAD,TABLE,3,1,1,time,BF%i%LOAD(1,0) = 0,0.5,1 BF%i%LOAD(1,1) = %i%*10,%i%*20,%i%*30*vwrite,i,ibfv,%i,hgen,%%BF%iLOAD%%*enddo*cfclos!create Solid model and mesh it\/prep7mp,kxx,1,50mp,dens,1,7850mp,c,1,450et,1,70block,,10,,1,,1block,10.1,20.1,,1,,1esize,.3vmesh,all\/inp,load,txt\/soluANTYPE,4TRNOPT,FULL LUMPM,0 TIME,1solve\/post1\/EFACET,1 PLNSOL, TEMP,, 0\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/apdl\\\/#listItem\",\"name\":\"apdl\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/apdl\\\/#listItem\",\"position\":3,\"name\":\"apdl\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/apdl\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\\\/#listItem\",\"name\":\"Is it possible to define multiple load (Heat generation rate) in table type array parameter using a *DO loop?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\\\/#listItem\",\"position\":4,\"name\":\"Is it possible to define multiple load (Heat generation rate) in table type array parameter using a *DO loop?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/apdl\\\/#listItem\",\"name\":\"apdl\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\\\/\",\"name\":\"Is it possible to define multiple load (Heat generation rate) in table type array parameter using a *DO loop? | Ansys Knowledge\",\"description\":\"Yes. The following APDL commands demonstrate how to define multiple loads using *do loop;Fini\\\/clear\\\/output,out,out*cfopen,load,txt*Do,i,1,2*DIM,BF%i%LOAD,TABLE,3,1,1,time,BF%i%LOAD(1,0) = 0,0.5,1 BF%i%LOAD(1,1) = %i%*10,%i%*20,%i%*30*vwrite,i,ibfv,%i,hgen,%%BF%iLOAD%%*enddo*cfclos!create Solid model and mesh it\\\/prep7mp,kxx,1,50mp,dens,1,7850mp,c,1,450et,1,70block,,10,,1,,1block,10.1,20.1,,1,,1esize,.3vmesh,all\\\/inp,load,txt\\\/soluANTYPE,4TRNOPT,FULL LUMPM,0 TIME,1solve\\\/post1\\\/EFACET,1 PLNSOL, TEMP,, 0\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\\\/#breadcrumblist\"},\"datePublished\":\"2022-06-06T09:58:16+00:00\",\"dateModified\":\"2022-06-06T09:58:16+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Is it possible to define multiple load (Heat generation rate) in table type array parameter using a *DO loop? | Ansys Knowledge","description":"Yes. The following APDL commands demonstrate how to define multiple loads using *do loop;Fini\/clear\/output,out,out*cfopen,load,txt*Do,i,1,2*DIM,BF%i%LOAD,TABLE,3,1,1,time,BF%i%LOAD(1,0) = 0,0.5,1 BF%i%LOAD(1,1) = %i%*10,%i%*20,%i%*30*vwrite,i,ibfv,%i,hgen,%%BF%iLOAD%%*enddo*cfclos!create Solid model and mesh it\/prep7mp,kxx,1,50mp,dens,1,7850mp,c,1,450et,1,70block,,10,,1,,1block,10.1,20.1,,1,,1esize,.3vmesh,all\/inp,load,txt\/soluANTYPE,4TRNOPT,FULL LUMPM,0 TIME,1solve\/post1\/EFACET,1 PLNSOL, TEMP,, 0","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/apdl\/#listItem","name":"apdl"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/apdl\/#listItem","position":3,"name":"apdl","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/apdl\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\/#listItem","name":"Is it possible to define multiple load (Heat generation rate) in table type array parameter using a *DO loop?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\/#listItem","position":4,"name":"Is it possible to define multiple load (Heat generation rate) in table type array parameter using a *DO loop?","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/apdl\/#listItem","name":"apdl"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\/","name":"Is it possible to define multiple load (Heat generation rate) in table type array parameter using a *DO loop? | Ansys Knowledge","description":"Yes. The following APDL commands demonstrate how to define multiple loads using *do loop;Fini\/clear\/output,out,out*cfopen,load,txt*Do,i,1,2*DIM,BF%i%LOAD,TABLE,3,1,1,time,BF%i%LOAD(1,0) = 0,0.5,1 BF%i%LOAD(1,1) = %i%*10,%i%*20,%i%*30*vwrite,i,ibfv,%i,hgen,%%BF%iLOAD%%*enddo*cfclos!create Solid model and mesh it\/prep7mp,kxx,1,50mp,dens,1,7850mp,c,1,450et,1,70block,,10,,1,,1block,10.1,20.1,,1,,1esize,.3vmesh,all\/inp,load,txt\/soluANTYPE,4TRNOPT,FULL LUMPM,0 TIME,1solve\/post1\/EFACET,1 PLNSOL, TEMP,, 0","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\/#breadcrumblist"},"datePublished":"2022-06-06T09:58:16+00:00","dateModified":"2022-06-06T09:58:16+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"Is it possible to define multiple load (Heat generation rate) in table type array parameter using a *DO loop? | Ansys Knowledge","og:description":"Yes. The following APDL commands demonstrate how to define multiple loads using *do loop;Fini\/clear\/output,out,out*cfopen,load,txt*Do,i,1,2*DIM,BF%i%LOAD,TABLE,3,1,1,time,BF%i%LOAD(1,0) = 0,0.5,1 BF%i%LOAD(1,1) = %i%*10,%i%*20,%i%*30*vwrite,i,ibfv,%i,hgen,%%BF%iLOAD%%*enddo*cfclos!create Solid model and mesh it\/prep7mp,kxx,1,50mp,dens,1,7850mp,c,1,450et,1,70block,,10,,1,,1block,10.1,20.1,,1,,1esize,.3vmesh,all\/inp,load,txt\/soluANTYPE,4TRNOPT,FULL LUMPM,0 TIME,1solve\/post1\/EFACET,1 PLNSOL, TEMP,, 0","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\/","article:published_time":"2022-06-06T09:58:16+00:00","article:modified_time":"2022-06-06T09:58:16+00:00","twitter:card":"summary_large_image","twitter:title":"Is it possible to define multiple load (Heat generation rate) in table type array parameter using a *DO loop? | Ansys Knowledge","twitter:description":"Yes. The following APDL commands demonstrate how to define multiple loads using *do loop;Fini\/clear\/output,out,out*cfopen,load,txt*Do,i,1,2*DIM,BF%i%LOAD,TABLE,3,1,1,time,BF%i%LOAD(1,0) = 0,0.5,1 BF%i%LOAD(1,1) = %i%*10,%i%*20,%i%*30*vwrite,i,ibfv,%i,hgen,%%BF%iLOAD%%*enddo*cfclos!create Solid model and mesh it\/prep7mp,kxx,1,50mp,dens,1,7850mp,c,1,450et,1,70block,,10,,1,,1block,10.1,20.1,,1,,1esize,.3vmesh,all\/inp,load,txt\/soluANTYPE,4TRNOPT,FULL LUMPM,0 TIME,1solve\/post1\/EFACET,1 PLNSOL, TEMP,, 0"},"aioseo_meta_data":{"post_id":"157982","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 17:59:34","updated":"2026-07-29 03:53:51","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/apdl\/\" title=\"apdl\">apdl<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tIs it possible to define multiple load (Heat generation rate) in table type array parameter using a *DO loop?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"apdl","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/apdl\/"},{"label":"Is it possible to define multiple load (Heat generation rate) in table type array parameter using a *DO loop?","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/is-it-possible-to-define-multiple-load-heat-generation-rate-in-table-type-array-parameter-using-a-do-loop\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["06-06-2022 20:20"],"_bbp_forum_id":["27789"],"_btv_view_count":["1087"],"_bbp_likes_count":["0"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/157982","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/157982\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=157982"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}