{"id":157346,"date":"2022-06-06T08:33:36","date_gmt":"2022-06-06T08:33:36","guid":{"rendered":"\/knowledge\/forums\/topic\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\/"},"modified":"2022-06-06T08:33:36","modified_gmt":"2022-06-06T08:33:36","slug":"how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2","status":"publish","type":"topic","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\/","title":{"rendered":"How to specify mixed compositions at an inlets with two mixture fractions?"},"content":{"rendered":"<p>With the Non-Premixed or Partially Premixed Combustion Models you can specify a so-called \u201cSecondary Stream\u201d. With the Secondary Stream you can model at least three different inlet compositions. In certain situations, you can model even more inlet compositions by combining streams. If you want to specify a mixture containing the Secondary Stream it is important to understand that the normalized mixture fraction (p_sec) is used when the user is prompted for Secondary Mixture Fraction in the Boundary Condition Panel. For example: If you want to specify at an inlet a mixture of 50 % of Fuel Stream composition and 50 % of Secondary Stream Composition, you can write: f_fuel + f_sec + f_ox = 1 0.5 + 0.5 = 1 and f_sec = p_sec * ( 1- f_fuel ) p_sec = f_sec \/ ( 1- f_fuel) p_sec = 0.5 \/ (1-0.5) p_sec = 1 &#8211;> At the inlet boundary condition you have to specify: Mean Mixture Fraction = 0.5 Secondary Mixture Fraction = 1<\/p>\n","protected":false},"template":"","class_list":["post-157346","topic","type-topic","status-publish","hentry","topic-tag-ansys-fluent","topic-tag-mixed-composition","topic-tag-reactions","topic-tag-secondary-stream"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"With the Non-Premixed or Partially Premixed Combustion Models you can specify a so-called \u201cSecondary Stream\u201d. With the Secondary Stream you can model at least three different inlet compositions. In certain situations, you can model even more inlet compositions by combining streams. If you want to specify a mixture containing the Secondary Stream it is important\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ansys Knowledge | Ansys Innovation Space\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"How to specify mixed compositions at an inlets with two mixture fractions? | Ansys Knowledge\" \/>\n\t\t<meta property=\"og:description\" content=\"With the Non-Premixed or Partially Premixed Combustion Models you can specify a so-called \u201cSecondary Stream\u201d. With the Secondary Stream you can model at least three different inlet compositions. In certain situations, you can model even more inlet compositions by combining streams. If you want to specify a mixture containing the Secondary Stream it is important\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2022-06-06T08:33:36+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2022-06-06T08:33:36+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"How to specify mixed compositions at an inlets with two mixture fractions? | Ansys Knowledge\" \/>\n\t\t<meta name=\"twitter:description\" content=\"With the Non-Premixed or Partially Premixed Combustion Models you can specify a so-called \u201cSecondary Stream\u201d. With the Secondary Stream you can model at least three different inlet compositions. In certain situations, you can model even more inlet compositions by combining streams. If you want to specify a mixture containing the Secondary Stream it is important\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"position\":2,\"name\":\"Topics\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/ansys-fluent\\\/#listItem\",\"name\":\"ansys-fluent\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/ansys-fluent\\\/#listItem\",\"position\":3,\"name\":\"ansys-fluent\",\"item\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/ansys-fluent\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\\\/#listItem\",\"name\":\"How to specify mixed compositions at an inlets with two mixture fractions?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/topics\\\/#listItem\",\"name\":\"Topics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\\\/#listItem\",\"position\":4,\"name\":\"How to specify mixed compositions at an inlets with two mixture fractions?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic-tag\\\/ansys-fluent\\\/#listItem\",\"name\":\"ansys-fluent\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\\\/#webpage\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\\\/\",\"name\":\"How to specify mixed compositions at an inlets with two mixture fractions? | Ansys Knowledge\",\"description\":\"With the Non-Premixed or Partially Premixed Combustion Models you can specify a so-called \\u201cSecondary Stream\\u201d. With the Secondary Stream you can model at least three different inlet compositions. In certain situations, you can model even more inlet compositions by combining streams. If you want to specify a mixture containing the Secondary Stream it is important\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/forums\\\/topic\\\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\\\/#breadcrumblist\"},\"datePublished\":\"2022-06-06T08:33:36+00:00\",\"dateModified\":\"2022-06-06T08:33:36+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#website\",\"url\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/\",\"name\":\"Ansys Knowledge\",\"description\":\"Ansys Innovation Space\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/innovationspace.ansys.com\\\/knowledge\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"How to specify mixed compositions at an inlets with two mixture fractions? | Ansys Knowledge","description":"With the Non-Premixed or Partially Premixed Combustion Models you can specify a so-called \u201cSecondary Stream\u201d. With the Secondary Stream you can model at least three different inlet compositions. In certain situations, you can model even more inlet compositions by combining streams. If you want to specify a mixture containing the Secondary Stream it is important","canonical_url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","position":1,"name":"Home","item":"https:\/\/innovationspace.ansys.com\/knowledge","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","position":2,"name":"Topics","item":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/ansys-fluent\/#listItem","name":"ansys-fluent"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/ansys-fluent\/#listItem","position":3,"name":"ansys-fluent","item":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/ansys-fluent\/","nextItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\/#listItem","name":"How to specify mixed compositions at an inlets with two mixture fractions?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/#listItem","name":"Topics"}},{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\/#listItem","position":4,"name":"How to specify mixed compositions at an inlets with two mixture fractions?","previousItem":{"@type":"ListItem","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/ansys-fluent\/#listItem","name":"ansys-fluent"}}]},{"@type":"Organization","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization","name":"Ansys Knowledge","description":"Ansys Innovation Space","url":"https:\/\/innovationspace.ansys.com\/knowledge\/"},{"@type":"WebPage","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\/#webpage","url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\/","name":"How to specify mixed compositions at an inlets with two mixture fractions? | Ansys Knowledge","description":"With the Non-Premixed or Partially Premixed Combustion Models you can specify a so-called \u201cSecondary Stream\u201d. With the Secondary Stream you can model at least three different inlet compositions. In certain situations, you can model even more inlet compositions by combining streams. If you want to specify a mixture containing the Secondary Stream it is important","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website"},"breadcrumb":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\/#breadcrumblist"},"datePublished":"2022-06-06T08:33:36+00:00","dateModified":"2022-06-06T08:33:36+00:00"},{"@type":"WebSite","@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#website","url":"https:\/\/innovationspace.ansys.com\/knowledge\/","name":"Ansys Knowledge","description":"Ansys Innovation Space","inLanguage":"en-US","publisher":{"@id":"https:\/\/innovationspace.ansys.com\/knowledge\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ansys Knowledge | Ansys Innovation Space","og:type":"article","og:title":"How to specify mixed compositions at an inlets with two mixture fractions? | Ansys Knowledge","og:description":"With the Non-Premixed or Partially Premixed Combustion Models you can specify a so-called \u201cSecondary Stream\u201d. With the Secondary Stream you can model at least three different inlet compositions. In certain situations, you can model even more inlet compositions by combining streams. If you want to specify a mixture containing the Secondary Stream it is important","og:url":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\/","article:published_time":"2022-06-06T08:33:36+00:00","article:modified_time":"2022-06-06T08:33:36+00:00","twitter:card":"summary_large_image","twitter:title":"How to specify mixed compositions at an inlets with two mixture fractions? | Ansys Knowledge","twitter:description":"With the Non-Premixed or Partially Premixed Combustion Models you can specify a so-called \u201cSecondary Stream\u201d. With the Secondary Stream you can model at least three different inlet compositions. In certain situations, you can model even more inlet compositions by combining streams. If you want to specify a mixture containing the Secondary Stream it is important"},"aioseo_meta_data":{"post_id":"157346","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-10-17 17:39:20","updated":"2026-07-29 03:21:20","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/\" title=\"Topics\">Topics<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/ansys-fluent\/\" title=\"ansys-fluent\">ansys-fluent<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tHow to specify mixed compositions at an inlets with two mixture fractions?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/innovationspace.ansys.com\/knowledge"},{"label":"Topics","link":"https:\/\/innovationspace.ansys.com\/knowledge\/topics\/"},{"label":"ansys-fluent","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic-tag\/ansys-fluent\/"},{"label":"How to specify mixed compositions at an inlets with two mixture fractions?","link":"https:\/\/innovationspace.ansys.com\/knowledge\/forums\/topic\/how-to-specify-mixed-compositions-at-an-inlets-with-two-mixture-fractions-2\/"}],"acf":[],"custom_fields":[{"0":{"_wp_page_template":["default"],"_bbp_last_active_time":["06-06-2022 20:20"],"_bbp_forum_id":["27784"],"_btv_view_count":["1175"],"_bbp_likes_count":["0"]},"test":"articlesansys-com"}],"_links":{"self":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/157346","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics"}],"about":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/types\/topic"}],"version-history":[{"count":0,"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/topics\/157346\/revisions"}],"wp:attachment":[{"href":"https:\/\/innovationspace.ansys.com\/knowledge\/wp-json\/wp\/v2\/media?parent=157346"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}